Noise assessments of urban rail transit stations with fully automatic operating systems

被引:0
|
作者
Cheng H. [1 ]
Liu C. [1 ,2 ]
Chen J. [1 ]
Zhong M. [1 ]
机构
[1] Institute of Public Safety Research, Department of Engineering Physics, Tsinghua University, Beijing
[2] Beijing Key Laboratory of City Integrated Emergency Response Science, Tsinghua University, Beijing
来源
Qinghua Daxue Xuebao/Journal of Tsinghua University | 2020年 / 60卷 / 01期
关键词
Equivalent continuous A-weighted sound pressure level; Full automatic operation; Noise; Urban rail transit;
D O I
10.16511/j.cnki.qhdxxb.2019.21.034
中图分类号
学科分类号
摘要
Urban rail transit systems will have fully automatic operation (FAO) in the near future. The noise characteristics of urban rail transit stations with fully automatic operating systems were investigated at 9 elevated stations along the YF line with noise measurements on the platforms, station halls, control rooms and equipment rooms. The average LAeq of the train arrival and departure noise were below the standard limits of 80 dB(A). The average LAeq in the station halls was 68~76 dB(A) with the high noise levels due to the PA system. The average LAeq in the control rooms was 47~65 dB(A). The average LAeq in the equipment control room ranged from 47 to 61 dB(A). The measured values were used to calculate the daily noise dose received by the station staff which ranged from 69 to 72 dB(A) during the day shift and from 66 to 69 dB(A) during the night shift. The fully automatic systems have lower noise levels than manual control systems and automatic train operation systems when trains are arriving and leaving the stations. © 2020, Tsinghua University Press. All right reserved.
引用
收藏
页码:18 / 24
页数:6
相关论文
共 16 条
  • [1] 2018 annual report of China urban mass transit, China Metro, 4, pp. 16-34, (2019)
  • [2] Liu G.Y., Li X.D., Origin and prevention of noise produced by urban track transport vehicle, Journal of Jiujiang Vocational and Technical College, 3, pp. 27-28, (2006)
  • [3] Shen M.L., Chen Z.L., Cheng L., Et al., Influence of and countermeasures against noise pollution of Shenyang Subway Line 1, Journal of Liaoning University (Natural Sciences Edition), 39, 2, pp. 123-126, (2012)
  • [4] Hu Z.H., Zhao Y.J., Comparison between noise pollution of elevated and underground parts of Xi'an Metro Line 3, Traffic & Transportation, 34, 5, pp. 65-67, (2018)
  • [5] Liu Q., Analysis on noise status of a newly built elevated station of urban rail transit-Part Ⅰ: Platform, Journal of Safety Science and Technology, 11, 2, pp. 145-153, (2015)
  • [6] Ryota S., Yoshiharu S., Characteristics of train noise in above-ground and underground stations with side and island platforms, Journal of Sound and Vibration, 330, 8, pp. 1621-1633, (2010)
  • [7] Liu Q., Analysis on noise status of underground platform in a typical line of urban metro, Journal of Safety Science and Technology, 11, 6, pp. 150-157, (2015)
  • [8] Zhou N.H., Yu Y.Y., Shi Y., Investigation on the noise effect of Nanjing Metro, The Administration and Technique of Environmental Monitoring, 18, 1, pp. 20-22, (2006)
  • [9] Gershon R.R.M., Neitzel R., Barrera M.A., Et al., Pilot survey of subway and bus stop noise levels, Journal of Urban Health, 83, 5, pp. 802-812, (2006)
  • [10] Acoustical Requirement and Measurement on Station Platform of Urban Rail Transit: GB 14227-2006, (2006)