3D transesophageal echocardiographic visualization of the pulmonary artery catheter through the tricuspid valve and their position relative to the tricuspid valve leaflets

被引:0
作者
Takada, Shoko [1 ]
Fujimoto, Tomoko [1 ]
Tomita-Kobayashi, Akiko [1 ]
Hayashi, Yukio [1 ,2 ]
机构
[1] Sakurabashi Watanabe Hosp, Anesthesiol Serv, 2-4-32 Umeda, Kita Ku, Osaka 5300001, Japan
[2] Yoka Municipal Hosp, Anesthesiol Serv, 1878-1 Yoka,Yoka Cho, Yabu, Hyogo 6678555, Japan
来源
JA CLINICAL REPORTS | 2024年 / 10卷 / 01期
关键词
Pulmonary artery catheter; 3-Dimensional transesophageal echocardiography; Tricuspid valve;
D O I
10.1186/s40981-024-00718-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background The tricuspid valve is an atrioventricular valve consisting of three lobes. We used the 3D transesophageal echocardiography to visualize position of the pulmonary artery catheter at the tricuspid valve annulus and examined where the catheter passed through at the level of the tricuspid annulus. Methods In this prospective and observational study, we monitored the pressure wave on patients undergoing cardiac surgery with the catheter placement by monitoring the pressure waveform for 8 months. We measured the time required for the catheter to pass through the tricuspid and pulmonary valves, respectively. We acquired the 3D image of the tricuspid valve by transesophageal echocardiography and determined the position of the pulmonary artery catheter at the level of the tricuspid annulus. The data were analyzed by Kruskal-Wallis test followed by Mann-Whitney test with Holm multiple comparisons. P < 0.05 was considered significant. Results Of the 116 cases, the pulmonary artery catheter passed through the tricuspid valve between antero-posterior leaflets in 78 cases (67.2 %), between septal-posterior leaflets in 25 cases (21.6 %), and between antero-septal leaflets in 2 cases (1.7 %) and the center in 11 cases (9.5 %), respectively. The time required for the catheter to pass through the pulmonary valves was significantly different among the catheter positions at the level of the tricuspid annulus. Conclusion The pulmonary artery catheter location at the level of the tricuspid annulus can be identified using 3D transesophageal echocardiography. The location of the catheter significantly affects the pulmonary artery catheter placement time.
引用
收藏
页数:6
相关论文
共 9 条
  • [1] Guidelines for Performing a Comprehensive Transesophageal Echocardiographic Examination: Recommendations from the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists
    Hahn, Rebecca T.
    Abraham, Theodore
    Adams, Mark S.
    Bruce, Charles J.
    Glas, Kathryn E.
    Lang, Roberto M.
    Reeves, Scott T.
    Shanewise, Jack S.
    Siu, Samuel C.
    Stewart, William
    Picard, Michael H.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (09) : 921 - 964
  • [2] Hamaba H, 2018, JA CLIN REP, V4, DOI 10.1186/s40981-018-0163-4
  • [3] All you need to know about the tricuspid valve: Tricuspid valve imaging and tricuspid regurgitation analysis
    Huttin, Olivier
    Voilliot, Damien
    Mandry, Damien
    Venner, Clement
    Juilliere, Yves
    Selton-Suty, Christine
    [J]. ARCHIVES OF CARDIOVASCULAR DISEASES, 2016, 109 (01) : 67 - 80
  • [4] 3D Echocardiographic Location of Implantable Device Leads and Mechanism of Associated Tricuspid Regurgitation
    Mediratta, Anuj
    Addetia, Karima
    Yamat, Megan
    Moss, Joshua D.
    Nayak, Hemal M.
    Burke, Martin C.
    Weinert, Lynn
    Maffessanti, Francesco
    Jeevanandam, Valluvan
    Mor-Avi, Victor
    Lang, Roberto M.
    [J]. JACC-CARDIOVASCULAR IMAGING, 2014, 7 (04) : 337 - 347
  • [5] An analysis of factors influencing pulmonary artery catheter passage through the tricuspid and pulmonary valves
    Miyata, Yuka
    Takada, Shoko
    Fujimoto, Tomoko
    Lwasaki, Mitsuo
    Hayashi, Yukio
    [J]. JA CLINICAL REPORTS, 2020, 6 (01)
  • [6] Rodriguez J M, 2003, Rev Esp Anestesiol Reanim, V50, P303
  • [7] Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads
    Seo, Yoshihiro
    Ishizu, Tomoko
    Nakajima, Hideki
    Sekiguchi, Yukio
    Watanabe, Shigeyuki
    Aonuma, Kazutaka
    [J]. CIRCULATION JOURNAL, 2008, 72 (09) : 1465 - 1470
  • [8] Right atrial membrane interfering with insertion of pulmonary artery catheter
    Yodfat, UA
    [J]. ANESTHESIOLOGY, 2000, 93 (02) : 576 - 578
  • [9] Facilitation of pulmonary artery catheter placement by transesophageal echocardiography after tricuspid valve surgery
    Zimmermann, P
    Steinhübel, B
    Greim, CA
    [J]. ANESTHESIA AND ANALGESIA, 2001, 93 (01) : 242 - 243