Comparison of estimations of urinary bladder volume in different scanning positions using 2D linear dimension formula and 3D bladder circumference tracing in client-owned cats

被引:0
作者
Ayoub, Sabrina [1 ]
Yiew, Xiu Ting [2 ]
Monteith, Gabrielle [2 ]
Willms, Allan R. [3 ]
机构
[1] Ontario Vet Coll Hlth Sci Ctr, Guelph, ON, Canada
[2] Ontario Vet Coll, Dept Clin Studies, Guelph, ON, Canada
[3] Univ Guelph, Coll Engn & Phys Sci, Dept Math & Stat, 50 Stone Rd East, Guelph, ON N1G 2W1, Canada
来源
CANADIAN JOURNAL OF VETERINARY RESEARCH-REVUE CANADIENNE DE RECHERCHE VETERINAIRE | 2024年 / 88卷 / 02期
关键词
ACCURACY; DOGS; ULTRASONOGRAPHY; COMPUTATION; VALIDATION; EXPRESSION; TRAUMA; IMPACT; SHAPE;
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Urinary bladder volume (UBV) can be estimated using point-of-care ultrasound. The purpose of this study was to compare 2 UBV estimation methods, i.e., three-dimensional (3D) bladder circumference tracing and 2-dimensional (2D) linear bladder dimension formula, against actual bladder volumes in awake client-owned cats and identify the best scanning position for UBV estimations. Up to 3 paired sets of orthogonal longitudinal and transverse bladder ultrasound images were acquired by a trained clinician from 21 cats positioned in dorsal, right lateral, and left lateral recumbency. UBV estimation was performed with these images by 2 different observers using both methods. Actual bladder volumes were measured through urethral catheterization and compared to the estimated UBV using Lin's concordance correlation coefficient and Bland-Altman analyses. Considering all positions, both methods showed substantial strength-of-agreement with actual bladder volumes; the 3D bladder circumference method (rho(c) = 0.963, 95% CI: 0.952 to 0.974) with a significant median bias of -4.08 mL (P < 0.001, IQR -7.63 to -0.68 mL, LOA -48.55 to 21.75 mL) and the 2D linear dimension method (rho(c) = 0.974, 95% CI: 0.966 to 0.982) with a median bias of -0.82 mL (P = 0.686, IQR -3.89 to 4.05 mL, LOA -35.23 to 35.21 mL). Scanning in left lateral recumbency provided the strongest strengths-of-agreement and precision against actual bladder volumes for both methods. Regardless of scanning positions, the 2D linear dimension method is more accurate than the 3D bladder circumference method, although both methods are imprecise with increasing volumes and UBV assessment through urinary catheterization remains the gold standard.
引用
收藏
页码:55 / 65
页数:11
相关论文
共 26 条
[1]   Effect of body position on ultrasonographic estimations of bladder volume [J].
Atalan, G ;
Holt, PE ;
Barr, FJ .
JOURNAL OF SMALL ANIMAL PRACTICE, 1999, 40 (04) :177-179
[2]  
Atalan G, 1998, AM J VET RES, V59, P10
[3]   Estimation of bladder volume-using ultrasonographic determination of cross-sectional areas and linear measurements [J].
Atalan, G ;
Barr, FJ ;
Holt, PE .
VETERINARY RADIOLOGY & ULTRASOUND, 1998, 39 (05) :446-450
[4]   Bladder shape impact on the accuracy of ultrasonic estimation of bladder volume [J].
Bih, LI ;
Ho, CC ;
Tsai, SJ ;
Lai, YC ;
Chow, W .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1998, 79 (12) :1553-1556
[5]   Effectiveness of manual bladder expression in paraplegic dogs [J].
Carwardine, Darren R. ;
Rose, Jeremy H. ;
Harcourt-Brown, Thomas R. ;
Granger, Nicolas .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2017, 78 (01) :107-112
[6]   Controversies in the management of feline urethral obstruction [J].
Cooper, Edward S. .
JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2015, 25 (01) :130-137
[7]   Catheter-induced urethral trauma in cats with urethral obstruction [J].
Corgozinho, Katia B. ;
de Souza, Heloisa J. M. ;
Pereira, Adriana N. ;
Belchior, Cristiane ;
da Silva, Michel A. ;
Martins, Marina C. L. ;
Damico, Cristiane B. .
JOURNAL OF FELINE MEDICINE AND SURGERY, 2007, 9 (06) :481-486
[8]   Evaluation of a 3-dimensional ultrasound device for noninvasive measurement of urinary bladder volume in dogs [J].
DiFazio, Matthew R. ;
Thomason, Justin D. ;
Cernicchiaro, Natalia ;
Biller, David ;
Thomason, Sasha ;
Harness, Paxton .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (04) :1488-1495
[9]   Portable ultrasonography and bladder volume accuracy - A comparative study using three-dimensional ultrasonography [J].
Ghani, Khurshid R. ;
Pilcher, James ;
Rowland, David ;
Patel, Uday ;
Nassiri, Daruish ;
Anson, Ken .
UROLOGY, 2008, 72 (01) :24-28
[10]   Occurrence of bacteriuria in 18 catheterised cats with obstructive lower urinary tract disease: a pilot study [J].
Hugonnard, Marine ;
Chalvet-Monfray, Karine ;
Dernis, Jeremy ;
Pouzot-Nevoret, Celine ;
Barthelemy, Anthony ;
Vialard, Jacquemine ;
Goy-Thollot, Isabelle .
JOURNAL OF FELINE MEDICINE AND SURGERY, 2013, 15 (10) :843-848