Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study

被引:4
|
作者
Gauci, Marc-Olivier [1 ]
Chaoui, Jean [2 ]
Berhouet, Julien [3 ]
Jacquot, Adrien [4 ]
Walch, Gilles [5 ]
Boileau, Pascal [1 ]
机构
[1] Univ Cote Azur UCA, CHU Nice, Inst Univ Locomoteur & Sport IULS, Unite Rech Clin Cote Azur UR2CA, Nice, France
[2] Imascap, Plouzane, France
[3] CHU Tours, Tours, France
[4] SAS Clin Louis Pasteur, Esseys Les Nancy, France
[5] Hop Prive Jean Mermoz, Ramsay Gen Sante, Lyon, France
关键词
Range of motion; 3D planning; reverse shoulder arthroplasty; notching; glenoid lateralization; BIO-RSA; LATERALIZATION; ROTATION; DESIGN;
D O I
10.1177/1758573221994141
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. Patients and Methods Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 766 yo) and impingements were analyzed. Inlay (155 degrees-inclined) and Onlay (145 degrees-inclined) humeral designs were tested. Four configurations were tested for each shoulder: "INLAY": non-lateralized glenoid-inlay humerus, "BIO-INLAY": lateralized glenoid (BIO-RSA)-inlay humerus, "ONLAY": non-lateralized glenoid-onlay humerus, and "BIO-ONLAY": lateralized (BIO-RSA) glenoid-onlay humerus. Results BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion (p<0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion (p<0.0001) and did not depend on the lateralization. Conclusion Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145 degrees inclination. Greater tuberosity abutment has to be avoided in abduction and the Inlay design provides the best abduction.
引用
收藏
页码:385 / 394
页数:10
相关论文
共 43 条
  • [21] Effect of humeral tray placement on impingement-free range of motion and muscle moment arms in reverse shoulder arthroplasty
    Glenday, Jonathan
    Kontaxis, Andreas
    Roche, Stephen
    Sivarasu, Sudesh
    CLINICAL BIOMECHANICS, 2019, 62 : 136 - 143
  • [22] The Real Post-Operative Range of Motion Differs from the Virtual Pre-Operative Planned Range of Motion in Reverse Shoulder Arthroplasty
    Berhouet, Julien
    Samargandi, Ramy
    Favard, Luc
    Turbillon, Celine
    Jacquot, Adrien
    Gauci, Marc-Olivier
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [23] Preoperative Planning for Reverse Shoulder Arthroplasty: Does the Clinical Range of Motion Match the Planned 3D Humeral Displacement?
    Yoon, Diane Ji Yun
    Odri, Guillaume-Anthony
    Favard, Luc
    Samargandi, Ramy
    Berhouet, Julien
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (05):
  • [24] Effect of humeral stem design on humeral position and range of motion in reverse shoulder arthroplasty
    Alexandre Lädermann
    Patrick J. Denard
    Pascal Boileau
    Alain Farron
    Pierric Deransart
    Alexandre Terrier
    Julien Ston
    Gilles Walch
    International Orthopaedics, 2015, 39 : 2205 - 2213
  • [25] Isometric strength, range of motion, and impairment before and after total and reverse shoulder arthroplasty
    Puskas, Brian
    Harreld, Kevin
    Clark, Rachel
    Downes, Katheryne
    Virani, Nazeem A.
    Frankle, Mark
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (07) : 869 - 876
  • [26] Effect of baseplate size on primary glenoid stability and impingement-free range of motion in reverse shoulder arthroplasty
    Chae, Soo-Won
    Kim, Soung-Yon
    Lee, Haea
    Yon, Joung-Ro
    Lee, Juneyoung
    Han, Seung-Ho
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [27] Effect of humeral stem and glenosphere designs on range of motion and muscle length in reverse shoulder arthroplasty
    Alexandre Lädermann
    Patrick J. Denard
    Philippe Collin
    Olivia Zbinden
    Joe Chih-Hao Chiu
    Pascal Boileau
    Flora Olivier
    Gilles Walch
    International Orthopaedics, 2020, 44 : 519 - 530
  • [28] The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion
    Langohr, G. Daniel G.
    Giles, Joshua W.
    Athwal, George S.
    Johnson, James A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (06) : 972 - 979
  • [29] Combined effect of change in humeral neck-shaft angle and retroversion on shoulder range of motion in reverse total shoulder arthroplasty - A simulation study
    Jeon, Byung-Kwan
    Panchal, Karnav A.
    Ji, Jong-Hun
    Xin, Yuan-Zhu
    Park, Sung-Ryeoll
    Kim, Joong-Hui
    Yang, Seok-Jo
    CLINICAL BIOMECHANICS, 2016, 31 : 12 - 19
  • [30] Assessment of Isokinetics and Range of Motion of the Shoulder in Patients after Reverse Shoulder Arthroplasty in the Late Follow-Up Period
    Ogrodzka-Ciechanowicz, Katarzyna
    Kurzeja, Piotr
    Sorysz, Tomasz
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (23)