Prediction of Intracranial Pressure in Patients with an Aneurysmal Subarachnoid Hemorrhage Using Optic Nerve Sheath Diameter via Explainable Predictive Modeling

被引:5
|
作者
Kim, Kwang Hyeon [1 ]
Kang, Hyung Koo [2 ]
Koo, Hae-Won [3 ]
机构
[1] Inje Univ, Ilsan Paik Hosp, Clin Res Support Ctr, Goyang 10380, South Korea
[2] Inje Univ, Coll Med, Ilsan Paik Hosp, Dept Internal Med,Div Pulm & Crit Care Med, Goyang 10380, South Korea
[3] Inje Univ, Coll Med, Ilsan Paik Hosp, Dept Neurosurg, Goyang 10380, South Korea
关键词
optic nerve sheath diameter; intracranial pressure; cerebral aneurysm; ultrasound; explainable artificial intelligence; SONOGRAPHIC ASSESSMENT; COMPUTED-TOMOGRAPHY; ULTRASONOGRAPHY; HYPERTENSION; RELIABILITY; ULTRASOUND;
D O I
10.3390/jcm13072107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The objective of this investigation was to formulate a model for predicting intracranial pressure (ICP) by utilizing optic nerve sheath diameter (ONSD) during endovascular treatment for an aneurysmal subarachnoid hemorrhage (aSAH), incorporating explainable predictive modeling. Methods: ONSD measurements were conducted using a handheld ultrasonography device during the course of endovascular treatment (n = 126, mean age 58.82 +/- 14.86 years, and female ratio 67.46%). The optimal ONSD threshold associated with an increased ICP was determined. Additionally, the association between ONSD and ICP was validated through the application of a linear regression machine learning model. The correlation between ICP and various factors was explored through the modeling. Results: With an ICP threshold set at 20 cmH2O, 82 patients manifested an increased ICP, with a corresponding ONSD of 0.545 +/- 0.08 cm. Similarly, with an ICP threshold set at 25 cmH2O, 44 patients demonstrated an increased ICP, with a cutoff ONSD of 0.553 cm. Conclusions: We revealed a robust correlation between ICP and ONSD. ONSD exhibited a significant association and demonstrated potential as a predictor of ICP in patients with an ICP >= 25 cmH2O. The findings suggest its potential as a valuable index in clinical practice, proposing a reference value of ONSD for increased ICP in the institution.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Evaluation of bedside sonographic measurement of optic nerve sheath diameter for assessment of raised intracranial pressure in adult head trauma patients
    Mathews, Alvin
    Cattamanchi, Srihari
    Panneerselvam, Tamilanbu
    Trichur, Ramakrishnan, V
    JOURNAL OF EMERGENCIES TRAUMA AND SHOCK, 2020, 13 (03) : 190 - 195
  • [42] Effect of intracranial pressure on the diameter of the optic nerve sheath
    Watanabe, Arata
    Kinouchi, Hiroyuki
    Horikoshi, Toru
    Uchida, Mikito
    Ishigame, Keiichi
    JOURNAL OF NEUROSURGERY, 2008, 109 (02) : 255 - 258
  • [43] Reliability of Assessing Non-severe Elevation of Intracranial Pressure Using Optic Nerve Sheath Diameter and Transcranial Doppler Parameters
    Chen, Li-min
    Wang, Li-juan
    Shi, Lin
    Chen, Hong-xiu
    Jiang, Xiao-han
    Chen, Qian-qian
    Xing, Ying-qi
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [44] The quantitative evaluation of intracranial pressure by optic nerve sheath diameter/eye diameter CT measurement
    Bekerman, Inessa
    Sigal, Tal
    Kimiagar, Itzhak
    Ben Ely, Anna
    Vaiman, Michael
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (12) : 2336 - 2342
  • [45] TRANSCRANIAL ULTRASOUND TO DETECT ELEVATED INTRACRANIAL PRESSURE: COMPARISON OF SEPTUM PELLUCIDUM UNDULATIONS AND OPTIC NERVE SHEATH DIAMETER
    Bolesch, Susanne
    von Wegner, Frederic
    Senft, Christian
    Lorenz, Matthias W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05) : 1233 - 1240
  • [46] Noninvasive Assessment of Intracranial Pressure: Deformability Index as an Adjunct to Optic Nerve Sheath Diameter to Increase Diagnostic Ability
    Netteland, Dag Ferner
    Aarhus, Mads
    Sandset, Else Charlotte
    Padayachy, Llewellyn
    Helseth, Eirik
    Brekken, Reidar
    NEUROCRITICAL CARE, 2024, 41 (02) : 479 - 488
  • [47] Ultrasonography Monitoring of Optic Nerve Sheath Diameter and Retinal Vessels in Patients with Cerebral Hemorrhage
    Naldi, Andrea
    Pivetta, Emanuele
    Coppo, Lorenzo
    Cantello, Roberto
    Comi, Cristoforo
    Stecco, Alessandro
    Cerrato, Paolo
    Lesmeister, Martin
    Lochner, Piergiorgio
    JOURNAL OF NEUROIMAGING, 2019, 29 (03) : 394 - 399
  • [48] Relationship between intracranial pressure as measured by an epidural intracranial pressure monitoring system and optic nerve sheath diameter in healthy dogs
    Ilie, Laura A.
    Thomovsky, Elizabeth J.
    Johnson, Paula A.
    Bentley, R. Timothy
    Heng, Hock Gan
    Lee, Hee C.
    Moore, George E.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (08) : 724 - 731
  • [49] Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure
    Amini, Afshin
    Kariman, Hamid
    Dolatabadi, Ali Arhami
    Hatamabadi, Hamid Reza
    Derakhshanfar, Hojjat
    Mansouri, Behnam
    Safari, Saeed
    Eqtesadi, Razie
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (01) : 236 - 239
  • [50] Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study
    Shirodkar, Chetan G.
    Rao, S. Manimala
    Mutkule, Dnyaneshwar P.
    Harde, Yogesh R.
    Venkategowda, Pradeep M.
    Mahesh, M. Uma
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2014, 18 (11) : 728 - 734