Prediction of Intracranial Pressure in Patients with an Aneurysmal Subarachnoid Hemorrhage Using Optic Nerve Sheath Diameter via Explainable Predictive Modeling

被引:5
|
作者
Kim, Kwang Hyeon [1 ]
Kang, Hyung Koo [2 ]
Koo, Hae-Won [3 ]
机构
[1] Inje Univ, Ilsan Paik Hosp, Clin Res Support Ctr, Goyang 10380, South Korea
[2] Inje Univ, Coll Med, Ilsan Paik Hosp, Dept Internal Med,Div Pulm & Crit Care Med, Goyang 10380, South Korea
[3] Inje Univ, Coll Med, Ilsan Paik Hosp, Dept Neurosurg, Goyang 10380, South Korea
关键词
optic nerve sheath diameter; intracranial pressure; cerebral aneurysm; ultrasound; explainable artificial intelligence; SONOGRAPHIC ASSESSMENT; COMPUTED-TOMOGRAPHY; ULTRASONOGRAPHY; HYPERTENSION; RELIABILITY; ULTRASOUND;
D O I
10.3390/jcm13072107
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The objective of this investigation was to formulate a model for predicting intracranial pressure (ICP) by utilizing optic nerve sheath diameter (ONSD) during endovascular treatment for an aneurysmal subarachnoid hemorrhage (aSAH), incorporating explainable predictive modeling. Methods: ONSD measurements were conducted using a handheld ultrasonography device during the course of endovascular treatment (n = 126, mean age 58.82 +/- 14.86 years, and female ratio 67.46%). The optimal ONSD threshold associated with an increased ICP was determined. Additionally, the association between ONSD and ICP was validated through the application of a linear regression machine learning model. The correlation between ICP and various factors was explored through the modeling. Results: With an ICP threshold set at 20 cmH2O, 82 patients manifested an increased ICP, with a corresponding ONSD of 0.545 +/- 0.08 cm. Similarly, with an ICP threshold set at 25 cmH2O, 44 patients demonstrated an increased ICP, with a cutoff ONSD of 0.553 cm. Conclusions: We revealed a robust correlation between ICP and ONSD. ONSD exhibited a significant association and demonstrated potential as a predictor of ICP in patients with an ICP >= 25 cmH2O. The findings suggest its potential as a valuable index in clinical practice, proposing a reference value of ONSD for increased ICP in the institution.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Correlation of optic nerve sheath diameter with intracranial pressure monitoring in patients with severe traumatic brain injury
    Sahoo, Siddhartha Shankar
    Agrawal, Deepak
    INDIAN JOURNAL OF NEUROTRAUMA, 2013, 10 (01) : 9 - 12
  • [32] Optic Nerve Sheath Diameter Ultrasound and the Diagnosis of Increased Intracranial Pressure
    Hylkema, Christopher
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2016, 28 (01) : 95 - +
  • [33] Point-of-care ultrasound of optic nerve sheath diameter to detect elevated intracranial pressure: Ultrasound in the eye of the beholder?
    Tjahjadi, N. S.
    van de Bergh, W.
    Elbers, P. W. G.
    Gommers, D.
    Tuinman, P. R.
    NETHERLANDS JOURNAL OF CRITICAL CARE, 2019, 27 (02): : 81 - 86
  • [34] Use of neuroimaging measurements of optic nerve sheath diameter to assess intracranial pressure in craniosynostosis
    Haredy, Mostafa
    Zuccoli, Giulio
    Tamber, Mandeep
    Davis, Amani
    Nischal, Ken
    Goldstein, Jesse A.
    CHILDS NERVOUS SYSTEM, 2018, 34 (05) : 939 - 946
  • [35] Sonography for Determining the Optic Nerve Sheath Diameter With Increasing Intracranial Pressure in a Porcine Model
    Hamilton, Douglas R.
    Sargsyan, Ashot E.
    Melton, Shannon L.
    Garcia, Kathleen M.
    Oddo, Bill
    Kwon, David S.
    Feiveson, Alan H.
    Dulchavsky, Scott A.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (05) : 651 - 659
  • [36] Interest of optic nerve sheath diameter ultrasonography in dectecting non-invasively raised intracranial pressure
    Messerer, M.
    Berhouma, M.
    Messerer, R.
    Dubourg, J.
    NEUROCHIRURGIE, 2013, 59 (02) : 55 - 59
  • [37] Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: a systematic review and meta-analysis
    Montorfano, Lisandro
    Yu, Qian
    Bordes, Stephen J.
    Sivanushanthan, Shankarapryan
    Rosenthal, Raul J.
    Montorfano, Miguel
    ULTRASOUND JOURNAL, 2021, 13 (01)
  • [38] Assessment of intracranial pressure with ultrasonographic measurement of optic nerve sheath diameter on patients undergoing suspension direct laryngoscopy
    Elif Karali
    Abdullah Demirhan
    Akif Günes
    Isa Yildiz
    Ahmet Ural
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 1835 - 1840
  • [39] Optic Nerve Sheath Diameter Assessment in Patients with Intracranial Pressure Monitoring
    Kavi, Tapan
    Gupta, Anuj
    Hunter, Krystal
    Schreiber, Craig
    Shaikh, Hamza
    Turtz, Alan R.
    CUREUS, 2018, 10 (11):
  • [40] Perioperative estimation of the intracranial pressure using the optic nerve sheath diameter during liver transplantation
    Krishnamoorthy, Vijay
    Beckmann, Katharina
    Mueller, Mark
    Sharma, Deepak
    Vavilala, Monica S.
    LIVER TRANSPLANTATION, 2013, 19 (03) : 246 - 249