Modified electrode placements for measurement of hemodynamic parameters using impedance cardiography

被引:1
作者
Hai V.D. [1 ]
Hung P.D. [1 ]
Dan C.Q. [1 ]
机构
[1] Biomedical Electronics Center, Hanoi University of Science and Technology, Hanoi
关键词
cardiac output; electrode placement; hemodynamic parameters; Impedance cardiography; stroke volume;
D O I
10.1080/03091902.2020.1799089
中图分类号
学科分类号
摘要
Measuring and monitoring hemodynamic parameters has brought many benefits in supporting diagnosis and treatment for cardiovascular patients. There are many advantages to measuring hemodynamic parameters by non-invasive technique based on impedance cardiography (ICG) such as simplicity, real-time and low cost. However, the electrode positions of this method are very difficult to implement in cases where the patient has to use multiple medical devices at the same time, especially for patients on active treatment and resuscitation. This paper presents the results of the study proposing new three locations of ICG electrodes to overcome the above limitation. Accordingly, we measured and evaluated 10 volunteers on the Niccomo device. The results show that all three positions of proposed electrode can be used to replace standard electrode position. In particular, the 1st proposed position, can be used to measure all five hemodynamic parameters HR, SV, LVET, Zo, CO and ICG waveforms, expressed by the average correlation and the relative average difference of five parameters, (Formula presented.) = 0.9641 and (Formula presented.) = 3.31%. The 2nd proposed position can be used to measure four parameters HR, SV, LVET, CO and ICG waveforms shown by (Formula presented.) = 0.9091 and (Formula presented.) = 8.67%. The 3rd proposed position can be used to measure three parameters HR, Zo and LVET, expressed by (Formula presented.) = 0.8485 and (Formula presented.) = 9.26%. © 2020 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:357 / 367
页数:10
相关论文
共 20 条
[1]  
Guyton C., Hall J.E., Textbook of medical of physiology, Int Ed, 20, pp. 232-245, (2006)
[2]  
Scherhag A., Kaden J., Kentschke E., Et al., Comparison of impedance cardiography and thermodilution derived measurements of stroke volume and cardiac output at rest and during exercise testing, Cardiovasc Drugs Ther, 19, 2, pp. 141-147, (2005)
[3]  
Webster J.G., Nimunkar A.J., Medical instrumentation: application and design, pp. 452-458, (2020)
[4]  
Charloux A., Lonsdorfer-Wolf E., Richard R., Et al., A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method, Eur J Appl Physiol, 82, 4, pp. 313-320, (2000)
[5]  
Charra B., Huchard G., Mion C., Et al., A dye-dilution cardiac output technique for hemodialyzed patients with arteriovenous fistula, Kidney Int, 3, 1, pp. 51-53, (1973)
[6]  
Gan T.J., Arrowsmith J.E., The oesophageal Doppler monitor, BMJ, 315, 7113, pp. 893-894, (1997)
[7]  
Berton C., Cholley B., Equipment review: New techniques for cardiac output measurement-oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis, Crit Care, 6, 3, pp. 216-221, (2002)
[8]  
Kubicek W.G., Karnegis J.N., Patterson R.P., Et al., Development and evaluation of an impedance cardiac output system, Aerosp Med, 37, 12, pp. 1208-1212, (1966)
[9]  
Weyer S., Menden T., Leicht L., Et al., Development of a wearable multi-frequency impedance cardiography device, J Med Eng Technol, 39, 2, pp. 131-137, (2015)
[10]  
Marik P.E., Noninvasive cardiac output monitors: a state-of the-art review, J Cardiothorac Vasc Anesth, 27, 1, pp. 121-134, (2013)