Position dispersive X-ray fluorescence

被引:0
|
作者
Webster J.L.V. [1 ,2 ]
Mcllquham J.D. [1 ,2 ]
Ganly B. [2 ]
机构
[1] University of Wollongong, Northfields Ave, Wollongong, 2522, NSW
[2] CSIRO, Building 67, New Illawarra Rd, Lucas Heights, 2234, NSW
来源
Radiat. Phys. Chem. | 2022年
关键词
The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Jack Webster reports financial support; equipment; drugs; or supplies; and writing assistance were provided by CSIRO Mineral Resources. Brianna Ganly reports financial support and equipment; or supplies were provided by CSIRO Mineral Resources. Jack Mcilquham reports financial support and equipment; or supplies were provided by CSIRO Mineral Resources. Jack Webster reports a relationship with University of Wollongong Faculty of Engineering and Information Sciences that includes: employment. Brianna Ganly reports a relationship with CSIRO Mineral Resources that includes: employment. Jack Mcilquham reports a relationship with CSIRO Mineral Resources that includes: employment;
D O I
10.1016/j.radphyschem.2022.110173
中图分类号
学科分类号
摘要
A novel scanning-free wavelength dispersive X-ray fluorescence spectrometer has been developed by combining low power X-ray tubes with X-ray optics. The X-rays are focused to a single point on the sample and then dispersed onto a flat diffracting crystal where they are spread depending on their energy through Bragg's law of diffraction onto a silicon strip detector. Throughout this study, the proposed method is referred to as Position Dispersive X-ray Fluorescence (PDXRF). The X-ray emission spectra of vanadium and copper as well as, CuO, CuS2 and V2O5 were measured. In the spectrometer energy resolutions of 3.14 eV and 8.94 eV FWHM were measured for V and Cu when measuring over a range of 4.8–5.8 keV and 6.2–9.1 keV respectively. The Kβ line shapes were fitted with a series of Voigt profiles and the energies and intensities of the Kβ valence transition peak, Kβ2,5, were determined. There was also sufficient variation in the intensity ratio of Kβ2,5/Kβ1,3 that the oxygen and sulphur compounds of V and Cu could be successfully observed and measured. The result demonstrates that this experimental setup is capable of measuring the Kβ line shape at resolutions of a few eV, allowing for chemical state analysis to be performed on 3d transition metals and their compounds such as the measurement of redox reactions to aid in battery development. © 2022
引用
收藏
相关论文
共 50 条
  • [1] Multivariate Data Analysis for Drug Identification Using Energy-Dispersive X-Ray Diffraction
    Cook, Emily J.
    Pani, Silvia
    George, Leah
    Hardwick, Sheila
    Horrocks, Julie A.
    Speller, Robert D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1459 - 1464
  • [2] The use of total reflectance X-ray fluorescence (TXRF) for the determination of metals in the pharmaceutical industry
    Antosz, Frederick J.
    Xiang, Yanqiao
    Diaz, Angel R.
    Jensen, Andrew J.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 62 : 17 - 22
  • [3] Microfocus x-ray fluorescence mapping of tumour penetration by an organo-osmium anticancer complex
    Sanchez-Cano, Carlos
    Romero-Canelon, Isolda
    Geraki, Kalotina
    Sadler, Peter J.
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2018, 185 : 26 - 29
  • [4] The performance of a fast testing system for illicit materials detection based on energy-dispersive X-ray diffraction technique
    Sun, Bai
    Li, Minqiang
    Zhang, Fang
    Zhong, Yu
    Kang, Nansheng
    Lu, Wei
    Liu, Jinhuai
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 293 - 297
  • [5] Applicability of total reflection X-ray fluorescence (TXRF) as a screening platform for pharmaceutical inorganic impurity analysis
    Shaw, Bradley J.
    Semin, David J.
    Rider, Michael E.
    Beebe, Meredith R.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 63 : 151 - 159
  • [6] The effects of device position on the operator's radiation dose when using a handheld portable X-ray device
    Makdissi, Jimmy
    Pawar, Ravikiran R.
    Johnson, Ben
    Chong, Bun S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (03)
  • [7] A high-quality multilayer structure characterization method based on X-ray fluorescence and Monte Carlo simulation
    Brunetti, Antonio
    Golosio, Bruno
    Melis, Maria Grazia
    Mura, Stefania
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2015, 118 (02): : 497 - 504
  • [8] Dose optimization in cardiac x-ray imaging
    Gislason-Lee, Amber J.
    McMillan, Catherine
    Cowen, Arnold R.
    Davies, Andrew G.
    MEDICAL PHYSICS, 2013, 40 (09)
  • [9] Synchrotron X-Ray Fluorescence Nanoprobe Reveals Target Sites for Organo-Osmium Complex in Human Ovarian Cancer Cells
    Sanchez-Cano, Carlos
    Romero-Canelon, Isolda
    Yang, Yang
    Hands-Portman, Ian J.
    Bohic, Sylvain
    Cloetens, Peter
    Sadler, Peter J.
    CHEMISTRY-A EUROPEAN JOURNAL, 2017, 23 (11) : 2512 - 2516
  • [10] SafeSpecs - A web based solution for x-ray equipment specification
    Lewis, CA
    Evans, DS
    PHYSICA MEDICA, 2001, 17 : 61 - 63