Open Circuit Fault Diagnosis Method of Electric Vehicle DC Charging Pile Based on Tensor Reshape Fusion Diagnostic Model

被引:0
作者
Liu Z. [1 ]
Jin T. [2 ]
Liu Y. [1 ]
Gong Z. [1 ]
Liao H. [1 ]
Lan M. [1 ]
机构
[1] College of Electrical Engineering and Automation, Fuzhou University, Fujian Province, Fuzhou
[2] Fujian Province University Engineering Research Center of Smart Distribution Grid Equipment, Fuzhou University, Fujian Province, Fuzhou
来源
Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering | 2023年 / 43卷 / 05期
基金
中国国家自然科学基金;
关键词
DC charging pile; deep learning; fault diagnosis;
D O I
10.13334/j.0258-8013.pcsee.213333
中图分类号
学科分类号
摘要
The open-circuit faults of EV charging piles affect power quality of power grid and threaten charging safety. Researches on the open-circuit fault diagnosis are of great significance to ensuring the safe and stable of the power grid and reducing the maintenance cost of the charging pile. According to the multidimensional characteristics of open circuit fault signals of charging piles, a tensor reshape fusion diagnostic model is proposed in this paper. In this method, the multidimensional feature parallel extraction ability of residual network (ResNet) and the sequential feature extraction ability of gated recurrent unit (GRU) are used to extract the front and rear stage fault features of the charging pile circuit, the fusion diagnosis is performed for front and rear stage features, and the high accuracy fault diagnosis of front and rear stage of charging pile is realized. A pre-processing method of front-stage three-phase fault signals based on tensor reshape method is proposed, which avoids the graphical input or one-dimensional input used by traditional deep learning algorithms and gives full play to the diagnostic performance of deep neural network. Compared with the traditional fault diagnosis method, the proposed method uses deep learning technology, which does not require manual selection of fault characteristic parameters. The simulation experiments show that the average accuracy of the proposed method can reach above 96% under the influence of different intensity noise; especially in the case of high noise with signal-noise ratio (SNR) of 10dB, the accuracy is still above 90%, and the accuracy of this method reaches 94.54% in experimental, which further verifies the effectiveness of this method. © 2023 Chin.Soc.for Elec.Eng.
引用
收藏
页码:1831 / 1842
页数:11
相关论文
共 24 条
  • [1] YU Dongmin, YANG Chao, JIANG Linru, Et al., Review on safety protection of electric vehicle charging, Proceedings of the CSEE, 42, 6, pp. 2145-2164, (2022)
  • [2] QIN Ling, KONG Xiaoxiao, XIE Shaojun, Et al., Robust PI controllers design of electrolytic capacitor-less DC charging spot in large parking lots, Proceedings of the CSEE, 38, 15, pp. 4514-4525, (2018)
  • [3] CHEN Yuxiang, LI Wuhua, IANNUZZO F, Et al., Investigation and classification of short-circuit failure modes based on three-dimensional safe operating area for high-power igbt modules, IEEE Transactions on Power Electronics, 33, 2, pp. 1075-1086, (2018)
  • [4] YANG Shaoyong, XIANG Dawei, BRYANT A, Et al., Condition monitoring for device reliability in power electronic converters: a review, IEEE Transactions on Power Electronics, 25, 11, pp. 2734-2752, (2010)
  • [5] SUN Keyao, WANG Jun, BURGOS R, Et al., Design, analysis, and discussion of short circuit and overload gate-driver dual-protection scheme for 1.2-kV, 400-A SiC MOSFET modules, IEEE Transactions on Power Electronics, 35, 3, pp. 3054-3068, (2020)
  • [6] PAZOUKI E, SOZER Y, DE ABREU-GARCIA J A., Fault diagnosis and fault-tolerant control operation of nonisolated DC-DC Converters, IEEE Transactions on Industry Applications, 54, 1, pp. 310-320, (2018)
  • [7] GAO Zhiwei, CECATI C, DING S X., A survey of fault diagnosis and fault-tolerant techniques — Part I: fault diagnosis with model-based and signal-based approaches, IEEE Transactions on Industrial Electronics, 62, 6, pp. 3757-3767, (2015)
  • [8] POON J, JAIN P, KONSTANTAKOPOULOS I C, Et al., Model-based fault detection and identification for switching power converters, IEEE Transactions on Power Electronics, 32, 2, pp. 1419-1430, (2017)
  • [9] ANAND A, RAJ N, Et al., A generalized switch fault diagnosis for cascaded H-bridge multilevel inverters using mean voltage prediction, IEEE Transactions on Industry Applications, 56, 2, pp. 1563-1574, (2020)
  • [10] GORLA N B Y, KOLLURI S, CHAI M, Et al., A novel open-circuit fault detection and localization scheme for cascaded h-bridge stage of a three-stage solid-state transformer, IEEE Transactions on Power Electronics, 36, 8, pp. 8713-8729, (2021)