Droplet microfluidic platform for extracellular vesicle isolation based on magnetic bead handling

被引:7
作者
Meggiolaro, Alessio [1 ]
Moccia, Valentina [2 ]
Sammarco, Alessandro [3 ,4 ]
Brun, Paola [5 ]
Damanti, Carlotta Caterina [6 ,7 ]
Crestani, Beatrice [1 ]
Mussolin, Lara [6 ,7 ]
Pierno, Matteo [1 ]
Mistura, Giampaolo [1 ]
Zappulli, Valentina [2 ]
Ferraro, Davide [1 ]
机构
[1] Univ Padua, Dept Phys & Astron, Via Marzolo 8, I-35131 Padua, Italy
[2] Univ Padua, Dept Comparat Biomed & Food Sci, Viale Univ 16, I-35020 Legnaro, Italy
[3] Massachusetts Gen Hosp, Dept Neurol, 149 13th St, Charlestown, MA 02129 USA
[4] Houston Methodist Res Inst, Dept Urol, 6670 Bertner Ave, Houston, TX 77030 USA
[5] Univ Padua, Dept Mol Med, Via Gabelli 63, I-35121 Padua, Italy
[6] Univ Padua, Dept Women & Child Hlth, Via Giustiniani 3, I-35128 Padua, Italy
[7] Ist Ric Pediat Citta Speranza, Corso Stati Uniti 4, I-35127 Padua, Italy
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2024年 / 409卷
关键词
Microfluidics; Extracellular vesicle; Isolation; Magnetic bead; EXOSOMES; CHIP; FLOW;
D O I
10.1016/j.snb.2024.135583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Extracellular vesicles (EVs) are rapidly gaining in popularity as biomarkers of various diseases, acting as cargoes of valuable information from the cell of origin. Despite their important value, their current use in clinical practice is still limited. One of the most limiting factors is their isolation. In fact, conventional approaches are characterized by low purity and throughput, or poor reproducibility. Here, we present a droplet microfluidic platform specifically developed for EV isolation by affinity capture with magnetic beads. This platform is capable of processing large sample volumes (2 mL) in a relatively short time (4.5 hours), with considerable automation. In detail, EVs and magnetic beads are co -encapsulated within the same droplet, which acts promoting their mixing due to the spontaneous recirculation; this continuous agitation prevents any loss usually caused by bead sedimentation and promotes the EV capturing. Our droplet microfluidic protocol is compared to a commercially available method, showing a shorter required incubation time (about 2.5 times) and a higher capture efficiency (2.5 -folds). The microfluidic approach is therefore positively evaluated in terms of protein content, EV quantification and microRNA cargo analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Magnetic-bead-based microfluidic system for ribonucleic acid extraction and reverse transcription processes
    Chien-Ju Liu
    Kang-Yi Lien
    Ching-Yi Weng
    Jyh-Wei Shin
    Tsuey-Yu Chang
    Gwo-Bin Lee
    Biomedical Microdevices, 2009, 11 : 339 - 350
  • [32] Microfluidic device for high-throughput affinity-based isolation of extracellular vesicles
    Lo, Ting-Wen
    Zhu, Ziwen
    Purcell, Emma
    Watza, Daniel
    Wang, Joyful
    Kang, Yoon-Tae
    Jolly, Shruti
    Nagrath, Deepak
    Nagrath, Sunitha
    LAB ON A CHIP, 2020, 20 (10) : 1762 - 1770
  • [33] Small extracellular vesicle-based one-step high-throughput microfluidic platform for epithelial ovarian cancer diagnosis
    Wu, Yu
    Wang, Chao
    Guo, Yuhan
    Zhang, Yunhong
    Zhang, Xue
    Wang, Pan
    Yue, Wei
    Zhu, Xin
    Liu, Zhaofei
    Zhang, Yu
    Guo, Hongyan
    Han, Lin
    Li, Mo
    JOURNAL OF NANOBIOTECHNOLOGY, 2025, 23 (01)
  • [34] Inter-Laboratory Comparison of Extracellular Vesicle Isolation Based on Ultracentrifugation
    Crigna, Adriana Torres
    Fricke, Fabia
    Nitschke, Katja
    Worst, Thomas
    Erb, Ulrike
    Karremann, Michael
    Buschmann, Dominik
    Elvers-Hornung, Susanne
    Tucher, Christine
    Schiller, Martin
    Hausser, Ingrid
    Gebert, Johannes
    Bieback, Karen
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2021, 48 (01) : 48 - 59
  • [35] Precipitation-based extracellular vesicle isolation from rat plasma co-precipitate vesicle-free microRNAs
    Karttunen, Jenni
    Heiskanen, Mette
    Navarro-Ferrandis, Vicente
    Das Gupta, Shalini
    Lipponen, Anssi
    Puhakka, Noora
    Rilla, Kirsi
    Koistinen, Arto
    Pitkanen, Asla
    JOURNAL OF EXTRACELLULAR VESICLES, 2019, 8 (01)
  • [36] Extraction of genomic DNA and detection of single nucleotide polymorphism genotyping utilizing an integrated magnetic bead-based microfluidic platform
    Lien, Kang-Yi
    Liu, Chien-Ju
    Lin, Yi-Chien
    Kuo, Pao-Lin
    Lee, Gwo-Bin
    MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (04) : 539 - 555
  • [37] Extraction of genomic DNA and detection of single nucleotide polymorphism genotyping utilizing an integrated magnetic bead-based microfluidic platform
    Kang-Yi Lien
    Chien-Ju Liu
    Yi-Chien Lin
    Pao-Lin Kuo
    Gwo-Bin Lee
    Microfluidics and Nanofluidics, 2009, 6 : 539 - 555
  • [38] Droplet-based microfluidic platform for measurement of rapid erythrocyte water transport
    Jin, Byung-Ju
    Esteva-Font, Cristina
    Verkman, A. S.
    LAB ON A CHIP, 2015, 15 (16) : 3380 - 3390
  • [39] Real time imaging of single extracellular vesicle pH regulation in a microfluidic cross-flow filtration platform
    Riazanski, Vladimir
    Mauleon, Gerardo
    Lucas, Kilean
    Walker, Samuel
    Zimnicka, Adriana M.
    McGrath, James L.
    Nelson, Deborah J.
    COMMUNICATIONS BIOLOGY, 2022, 5 (01)
  • [40] Extracellular vesicle and lipoprotein diagnostics (ExoLP-Dx) with membrane sensor: A robust microfluidic platform to overcome heterogeneity
    Kumar, Sonu
    Senapati, Satyajyoti
    Chang, Hsueh-Chia
    BIOMICROFLUIDICS, 2024, 18 (04)