Droplet microfluidic platform for extracellular vesicle isolation based on magnetic bead handling

被引:7
作者
Meggiolaro, Alessio [1 ]
Moccia, Valentina [2 ]
Sammarco, Alessandro [3 ,4 ]
Brun, Paola [5 ]
Damanti, Carlotta Caterina [6 ,7 ]
Crestani, Beatrice [1 ]
Mussolin, Lara [6 ,7 ]
Pierno, Matteo [1 ]
Mistura, Giampaolo [1 ]
Zappulli, Valentina [2 ]
Ferraro, Davide [1 ]
机构
[1] Univ Padua, Dept Phys & Astron, Via Marzolo 8, I-35131 Padua, Italy
[2] Univ Padua, Dept Comparat Biomed & Food Sci, Viale Univ 16, I-35020 Legnaro, Italy
[3] Massachusetts Gen Hosp, Dept Neurol, 149 13th St, Charlestown, MA 02129 USA
[4] Houston Methodist Res Inst, Dept Urol, 6670 Bertner Ave, Houston, TX 77030 USA
[5] Univ Padua, Dept Mol Med, Via Gabelli 63, I-35121 Padua, Italy
[6] Univ Padua, Dept Women & Child Hlth, Via Giustiniani 3, I-35128 Padua, Italy
[7] Ist Ric Pediat Citta Speranza, Corso Stati Uniti 4, I-35127 Padua, Italy
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2024年 / 409卷
关键词
Microfluidics; Extracellular vesicle; Isolation; Magnetic bead; EXOSOMES; CHIP; FLOW;
D O I
10.1016/j.snb.2024.135583
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Extracellular vesicles (EVs) are rapidly gaining in popularity as biomarkers of various diseases, acting as cargoes of valuable information from the cell of origin. Despite their important value, their current use in clinical practice is still limited. One of the most limiting factors is their isolation. In fact, conventional approaches are characterized by low purity and throughput, or poor reproducibility. Here, we present a droplet microfluidic platform specifically developed for EV isolation by affinity capture with magnetic beads. This platform is capable of processing large sample volumes (2 mL) in a relatively short time (4.5 hours), with considerable automation. In detail, EVs and magnetic beads are co -encapsulated within the same droplet, which acts promoting their mixing due to the spontaneous recirculation; this continuous agitation prevents any loss usually caused by bead sedimentation and promotes the EV capturing. Our droplet microfluidic protocol is compared to a commercially available method, showing a shorter required incubation time (about 2.5 times) and a higher capture efficiency (2.5 -folds). The microfluidic approach is therefore positively evaluated in terms of protein content, EV quantification and microRNA cargo analysis.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Development of a microfluidic droplet platform with an antibody-free magnetic-bead-based strategy for high through-put and efficient EVs isolation
    Morani, Marco
    Taverna, Myriam
    Krupova, Zuzana
    Alexandre, Lucile
    Defrenaix, Pierre
    Mai, Thanh Duc
    TALANTA, 2022, 249
  • [2] Rapid automated extracellular vesicle isolation and miRNA preparation on a cost-effective digital microfluidic platform
    Tong, Zhaoduo
    Yang, Dawei
    Shen, Chuanjie
    Li, Chao
    Xu, Xin
    Li, Qiushi
    Wu, Zhenhua
    Ma, Hui
    Chen, Fuxiang
    Mao, Hongju
    ANALYTICA CHIMICA ACTA, 2024, 1296
  • [3] Isolation of cancer-derived extracellular vesicle subpopulations by a size-selective microfluidic platform
    Chen, Zheyuan
    Yang, Yi
    Yamaguchi, Hirohito
    Hung, Mien-Chi
    Kameoka, Jun
    BIOMICROFLUIDICS, 2020, 14 (03)
  • [4] Optimization of blood handling for plasma extracellular vesicle isolation
    Kabagwira, Janviere
    Gonda, Amber
    Vallejos, Paul
    Babcock, Blake
    Langridge, William H. R.
    Senthil, Maheswari
    Wall, Nathan R.
    JOURNAL OF NANOPARTICLE RESEARCH, 2021, 23 (03)
  • [5] Optimization of blood handling for plasma extracellular vesicle isolation
    Janviere Kabagwira
    Amber Gonda
    Paul Vallejos
    Blake Babcock
    William H. R. Langridge
    Maheswari Senthil
    Nathan R. Wall
    Journal of Nanoparticle Research, 2021, 23
  • [6] Microfluidic platforms for extracellular vesicle isolation, analysis and therapy in cancer
    Abreu, Catarina M.
    Costa-Silva, Bruno
    Reis, Rui L.
    Kundu, Subhas C.
    Caballero, David
    LAB ON A CHIP, 2022, 22 (06) : 1093 - 1125
  • [7] Microfluidic Strategies for Extracellular Vesicle Isolation: Towards Clinical Applications
    Meggiolaro, Alessio
    Moccia, Valentina
    Brun, Paola
    Pierno, Matteo
    Mistura, Giampaolo
    Zappulli, Valentina
    Ferraro, Davide
    BIOSENSORS-BASEL, 2023, 13 (01):
  • [8] Bead-Based Extracellular Vesicle Analysis Using Flow Cytometry
    Yang, Katherine S.
    Lin, Hsing-Ying
    Curley, Caleigh
    Welch, Marisa W.
    Wolpin, Brian M.
    Lee, Hakho
    Weissleder, Ralph
    Im, Hyungsoon
    Castro, Cesar M.
    ADVANCED BIOSYSTEMS, 2020, 4 (12)
  • [9] Automated microfluidic processing platform for multiplexed magnetic bead immunoassays
    Sasso, Lawrence A.
    Johnston, Ian H.
    Zheng, Mingde
    Gupte, Rohit K.
    Uendar, Akif
    Zahn, Jeffrey D.
    MICROFLUIDICS AND NANOFLUIDICS, 2012, 13 (04) : 603 - 612
  • [10] Microfluidic Approaches and Methods Enabling Extracellular Vesicle Isolation for Cancer Diagnostics
    Singh, Premanshu Kumar
    Patel, Aarti
    Kaffenes, Anastasia
    Hord, Catherine
    Kesterson, Delaney
    Prakash, Shaurya
    MICROMACHINES, 2022, 13 (01)