Specific and Simultaneous Detection of E. coli O157:H7 and Shiga-like Toxins Using a Label-Free Photonic Immunosensor

被引:1
作者
Fernandez, Ana [1 ]
Hernandez, Manuel [2 ]
Moreno, Yolanda [3 ]
Garcia-Hernandez, Jorge [2 ]
机构
[1] Lumensia Snsors S L, Valencia 46020, Spain
[2] Univ Politecn Valencia, Ctr Avanzado Microbiol Alimentos, Biotechnol Dept, Valencia 46022, Spain
[3] Univ Politecn Valencia, Inst Ingn Agua & Medioambiente, Valencia 46022, Spain
关键词
E. coli O157; food safety; photonic immunosensor; label-free method; ring resonators; photon transduction; ESCHERICHIA-COLI; RAPID DETECTION; IMMUNOMAGNETIC SEPARATION; OPTICAL BIOSENSORS; PATHOGEN DETECTION; FOOD SAFETY; O157/H7; O157-H7; GOLD; SAMPLES;
D O I
10.3390/photonics11040374
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The current study outlines the advancement of an innovative technique for the simultaneous detection of E. coli O157:H7 and its Shiga-like toxins in food samples by utilizing a photonic label-free biosensor coupled with a microfluidic system. This detection method relies on ring resonator transduction that is functionalized with specific bioreceptors against O157:H7 on silicon nitride surfaces capable of binding specifically to the antigen bacterium and its verotoxins. This experiment included the characterization of selected monoclonal and polyclonal antibodies employed as detection probes through ELISA immunoassays exposed to target bacterial antigens. A thorough validation of photonic immunosensor detection was conducted on inoculated minced beef samples using reference standards for E. coli O157:H7 and its verotoxins (VTx1 and VTx2) and compared to gold-standard quantification. The lowest limit-of-detection values of 10 CFU/mL and 1 ppm were achieved for the detection of bacteria and its verotoxins. In this study, the lowest limit of quantification (LoQ) achieved for bacterial quantification was 100 CFU/mL, and, for verotoxins, it was 2 ppm. This study confirmed the effectiveness of a new quality control and food hygiene method, demonstrating the rapid and sensitive detection of E. coli O157:H7 and its verotoxins. This innovative approach has the potential to be applied in food production environments.
引用
收藏
页数:23
相关论文
共 76 条
  • [1] Electrochemical Genosensor To Detect Pathogenic Bacteria (Escherichia coil O157:H7) As Applied in Real Food Samples (Fresh Beef) To Improve Food Safety and Quality Control
    Abdalhai, Mandour H.
    Fernandes, Antonio Maximiano
    Xia, Xiaofeng
    Musa, Abubakr
    Ji, Jian
    Sun, Xiulan
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2015, 63 (20) : 5017 - 5025
  • [2] Highly sensitive and rapid determination of Escherichia coli O157:H7 in minced beef and water using electrocatalytic gold nanoparticle tags
    Abdel-Azzem Hassan, Abdel-Rahim Hussein
    de la Escosura-Muniz, Alfredo
    Merkoci, Arben
    [J]. BIOSENSORS & BIOELECTRONICS, 2015, 67 : 511 - 515
  • [3] An optical biosensor for rapid and label-free detection of cells
    Acharya, G
    Chang, CL
    Savran, C
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (12) : 3862 - 3863
  • [4] [Anonymous], 2005, OFFICIAL J EUROPEAN, V338, P1, DOI DOI 10.1109/MACE.2010.5536537
  • [5] RAPID METHOD TO DETECT SHIGA TOXIN AND SHIGA-LIKE TOXIN-I BASED ON BINDING TO GLOBOTRIOSYL CERAMIDE (GB3), THEIR NATURAL RECEPTOR
    ASHKENAZI, S
    CLEARY, TG
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1989, 27 (06) : 1145 - 1150
  • [6] Microfluidic immunosensor systems
    Bange, A
    Halsall, HB
    Heineman, WR
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) : 2488 - 2503
  • [7] Development of Optical Label-Free Biosensor Method in Detection of Listeria monocytogenes from Food
    Blanco, Ana Fernandez
    Perez, Manuel Hernandez
    Trigos, Yolanda Moreno
    Garcia-Hernandez, Jorge
    [J]. SENSORS, 2023, 23 (12)
  • [8] Optical biosensors
    Borisov, Sergey M.
    Wolfbeis, Otto S.
    [J]. CHEMICAL REVIEWS, 2008, 108 (02) : 423 - 461
  • [9] Application of DNA Aptamers and Quantum Dots to Lateral Flow Test Strips for Detection of Foodborne Pathogens with Improved Sensitivity versus Colloidal Gold
    Bruno, John G.
    [J]. PATHOGENS, 2014, 3 (02) : 341 - 355
  • [10] Advances in Screening, Detection and Enumeration of Escherichia coli Using Nanotechnology-Based Methods: A Review
    Carvalho, Freda
    George, Jacinta
    Sheikh, Huda Mohammed Ahmed
    Selvin, Rosilda
    [J]. JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2018, 14 (05) : 829 - 846