eThree-Month Clinical Outcomes to Correct Myopia or Myopic Astigmatism Using a Femtosecond Laser for Lenticule Creation With Automated Centration and Cyclotorsion Compensation

被引:2
|
作者
Yoon, Hyosung [1 ]
Magnago, Thomas [2 ]
Yeom, Donjg-Ju [1 ]
机构
[1] SMILE Eye Clin, Seoul, South Korea
[2] SCHWIND Eye Tech Solut GmbH, Kleinostheim, Germany
关键词
IN-SITU KERATOMILEUSIS; EXTRACTION SMILE; REFRACTIVE SURGERY; ABERRATIONS; STANDARD;
D O I
10.3928/1081597X-20231212-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To individually evaluate the clinical outcomes for right and left eyes in the first 3 months after laser-assisted lenticule extraction for myopia and myopic astigmatism with the use of the new ATOS femtosecond laser system (SmartSight; SCHWIND eye-tech-solutions). METHODS: A total of 331 eyes from 168 patients (166 right eyes and 165 left eyes) consecutively treated with SmartSight lenticule extraction were retrospective analyzed after a 3-month follow-up period. Patients' mean age was 26 +/- 6 years (range: 18 to 47 years) and mean preoperative spherical equivalent (SEQ) was -5.07 +/- 1.92 diopters [D] (range: -1.50 to -11.25 D) with a mean astigmatism of -1.04 +/- 0.85 D (range: 0.00 to -4.00 D). At 3 months of follow-up, visual acuity, SEQ and cylinder, safety index, efficacy index, corneal higher order aberrations, and intraocular pressure (IOP) were analyzed. Furthermore, refractive and visual outcomes were also analyzed for the right and left eyes individually. All lenticule extraction treatments were performed with the SmartSight treatment method of the SCHWIND ATOS femtosecond laser. RESULTS: At 3 months after surgery, mean SEQ was -0.12 +/- 0.19 D and 98% of eyes were within +/- 0.50 D of the SEQ. All eyes were within +/- 1.00 D of the SEQ. Astigmatism of 0.50 D or less was achieved in 99% of eyes. The change in Snellen lines (difference between preoperative corrected distance visual acuity and postoperative uncorrected distance visual acuity) showed a gain of one or more lines in 13% and in 85% of the eyes the same was achieved. There was a loss of one or more lines at 3 months of follow-up in 1.6%. The safety index was 1.03 and efficacy index was 1.02. No significant difference between the right and left eyes was found. CONCLUSIONS: The 3-month follow-up data show that SmartSight treatment for correction of myopia and myopic astigmatism with the SCHWIND ATOS is a safe, efficient, and accurate procedure. It provided excellent results in terms of visual recovery, predictability, and higher order aberrations.
引用
收藏
页码:E30 / E41
页数:12
相关论文
共 3 条
  • [1] 12-Month Visual and Refractive Outcomes of Topography-guided Femtosecond Laser- Assisted LASIK for Myopia and Myopic Astigmatism
    Saleh, Solin
    Epp, Liam J.
    Tran, Elaine My Tien
    Manche, Edward E.
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (09) : e595 - e603
  • [2] Early visual outcomes and optical quality after femtosecond laser small-incision lenticule extraction for myopia and myopic astigmatism correction of over-10 dioptres
    Qin, Bing
    Li, Meiyan
    Chen, Xun
    Sekundo, Walter
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2018, 96 (03) : E341 - E346
  • [3] The comparison of visual outcomes, aberrations, and Bowman's layer micro-distortions after femtosecond laser small-incision lenticule extraction (SMILE) for the correction of high and moderate myopia and myopic astigmatism
    Qin, Bing
    Zhao, Jing
    Li, Meiyan
    Yao, Peijun
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2019, 19 (1)