Mercury (II) sensing using a simple turn-on fluorescent graphene oxide based aptasensor in serum and water samples

被引:5
作者
Chaghazardi, Mosayeb [1 ,2 ]
Kashanian, Soheila [3 ,4 ,5 ]
Nazari, Maryam [1 ]
Omidfar, Kobra [2 ,6 ]
Shariati-Rad, Masoud [7 ]
Joseph, Yvonne [8 ,9 ]
Rahimi, Parvaneh [8 ,9 ]
机构
[1] Razi Univ, Fac Chem, Kermanshah, Iran
[2] Univ Tehran Med Sci, Endocrinol & Metab Mol Cellular Sci Inst, Biosensor Res Ctr, Tehran 1411413137, Iran
[3] Razi Univ, Fac Chem, Kermanshah, Iran
[4] Razi Univ, Nanosci & Nanotechnol Res Ctr NNRC, Kermanshah, Iran
[5] Razi Univ, Fac Innovat Sci & Technol, Nanobiotechnol Dept, Kermanshah, Iran
[6] Univ Tehran Med Sci, Endocrinol & Metab Clin Sci Inst, Endocrinol & Metab Res Ctr, Tehran, Iran
[7] Razi Univ, Fac Chem, Dept Analyt Chem, Kermanshah, Iran
[8] Tech Univ Bergakademie Freiberg, Inst Nanoscale & Biobased Mat, Fac Mat Sci & Mat Technol, D-09599 Freiberg, Germany
[9] Tech Univ Bergakademie Freiberg, Water Res Ctr, D-09599 Freiberg, Germany
关键词
Fluorescence; Aptasensor; Mercury; Graphene oxide; Real samples analysis; MULTIVARIATE CURVE RESOLUTION; LEAST-SQUARES; SENSITIVE DETECTION; SEA-WATER; DNA; HG2+; APTAMER; IONS; NANOPARTICLES; SPECTROMETRY;
D O I
10.1016/j.saa.2024.124057
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple, highly sensitive, and selective fluorometric aptasensing platform based on aptamer and graphene oxide (GO) is proposed for the determination of mercury (II) ion (Hg2+). In the designed assay, two aptamer probes, a carboxy-fluorescein (FAM) labeled aptamer (aptamer A) and its complementary (aptamer B) with partial complement containing several mismatches and GO as the quencher were used. In the absence of Hg2+, both A and B aptamers were adsorbed on the surface of GO by pi-pi-stacking, leading to fluorescence quenching of FAM due to fluorescence resonance energy transfer (FRET). Upon exposure to Hg2+, the A and B aptamer strands bind Hg2+ and form T-Hg2+-T complexes, leading to the formation of a stable double -stranded aptamer. The doublestranded aptamer is detached from the GO surface, resulting in the recovery of FAM fluorescence. The fluorescence intensity (FI) of the developed sensor was correlated with the Hg2+ concentration under optimized experimental conditions in two wide linear ranges, even in the presence of 10 divalent cations as interferences. The linear ranges were obtained from 200.0 to 900.0 fM and 5.0 to 33.0 pM, a limit of detection (LOD) of 106.0 fM, and a limit of quantification (LOQ) of 321.3 fM. The concentration of Hg2+ was determined in five real samples containing three water and two serum samples, using spiking and standard addition methods and the results were compared with the spiked amounts and atomic absorption (AAS) as standard method respectively, with acceptable recoveries. Furthermore, in the standard addition method, to overcome the effects of matrix influence of real samples in quantitative predictions, the excitation -emission matrix (EEM) data for samples was simultaneously analyzed by multivariate curve resolution with alternating least squares (MCR-ALS) as a secondorder standard addition method (SOSAM).
引用
收藏
页数:13
相关论文
共 101 条
  • [51] A study of deproteinization methods for subsequent serum analysis with capillary electrophoresis
    Ralston, PB
    Strein, TG
    [J]. MICROCHEMICAL JOURNAL, 1997, 55 (02) : 270 - 283
  • [52] Detection of mercury ion using surface plasmon resonance spectroscopy based on nanocrystalline cellulose/poly(3,4-ethylenedioxythiophene) thin film
    Ramdzan, Nur Syahira Md
    Fen, Yap Wing
    Omar, Nur Alia Sheh
    Anas, Nur Ain Asyiqin
    Liew, Josephine Ying Chyi
    Daniyal, Wan Mohd Ebtisyam Mustaqim Mohd
    Hashim, Hazwani Suhaila
    [J]. MEASUREMENT, 2021, 182
  • [53] "In vitro" behaviour of aptamer-functionalized polymeric nanocapsules loaded with 5-fluorouracil for targeted therapy
    Rata, Delia Mihaela
    Cadinoiu, Anca Niculina
    Atanase, Leonard Ionut
    Bacaita, Simona Elena
    Mihalache, Cristian
    Daraba, Oana-Maria
    Gherghel, Daniela
    Popa, Marcel
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 103
  • [54] Reddy V, 2012, INT J ELECTROCHEM SC, V7, P11058
  • [55] Rhouati A, 2018, MICRO NANO TECHNOL, P193, DOI 10.1016/B978-0-12-813855-7.00007-6
  • [56] Aptamer functionalized curcumin-loaded human serum albumin (HSA) nanoparticles for targeted delivery to HER-2 positive breast cancer cells
    Saleh, Tayebeh
    Soudi, Tooba
    Shojaosadati, Seyed Abbas
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 130 : 109 - 116
  • [57] Highly collinear three-way photoinduced spectrofluorimetric data arrays modelled with bilinear least-squares:: Determination of tetracyclines in surface water samples
    Santiago Valverde, Rosario
    Gil Garcia, M. Dolores
    Martinez Galera, M.
    Goicoechea, Hector C.
    [J]. TALANTA, 2006, 70 (04) : 774 - 783
  • [58] Strategies for solving matrix effects in the analysis of triphenyltin in sea-water samples by three-way multivariate curve resolution
    Saurina, J
    Tauler, R
    [J]. ANALYST, 2000, 125 (11) : 2038 - 2043
  • [59] Procedure for the quantitative determination of mixtures of nucleic acid components based on multivariate spectrophotometric acid-base titrations
    Saurina, J
    Hernández-Cassou, S
    Tauler, R
    Izquierdo-Ridorsa, A
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (01) : 126 - 134
  • [60] Determination of triphenyltin in sea-water by excitation-emission matrix fluorescence and multivariate curve resolution
    Saurina, J
    Leal, C
    Compañó, R
    Granados, M
    Tauler, R
    Prat, MD
    [J]. ANALYTICA CHIMICA ACTA, 2000, 409 (1-2) : 237 - 245