Reliability analysis of helium pressure non-destructive testing method of the fuel rod

被引:0
|
作者
Huang F. [1 ]
Zhu Z. [1 ]
Cao H. [1 ]
Yu W. [1 ]
Meng X. [1 ]
机构
[1] CNNC Nuclear Fuel Components Co., Ltd., Yibin
来源
He Jishu/Nuclear Techniques | 2023年 / 46卷 / 07期
关键词
Fuel rods; Helium pressure; Non-destructive testing; Puncture manometry; Reliability;
D O I
10.11889/j.0253-3219.2023.hjs.46.070607
中图分类号
学科分类号
摘要
[Background] Currently, the destructive puncture manometry method is used to measure helium pressure inside fuel rods. However, this method is expensive and does not guarantee 100% coverage. Hence the nondestructive testing (NDT) equipment is introduced for non-destructive measurement of helium pressure inside fuel rods. [Purpose] This study aims to analyze the reliability of NDT testing method for the measurement of helium pressure inside fuel rods. [Methods] Three standard rods with helium pressure values of 0.98 MPa, 1.76 MPa, 2.45 MPa, respectively, were selected for experimental test. The experimental fuel rods were first used to obtain the results comparison of heat transfer method and puncture manometry, then the control variates were employed to control the fuel rod temperature, the time interval of a single measurement, and the ambient temperature respectively, so as to determine influencing factors in the NDT method. Finally, reliability analysis of NDT method was performed according to experimental results. [Results] The results of the NDT method are consistent with that of the puncture manometry method at a temperature range of 24~30 ºC with less than 0.05 MPa deviation. Minimum repeat measurement time interval for NDT measuring helium pressure of the same standard rod or fuel rod is 2 min. [Conclusions] The NDT method for measuring the helium pressure of fuel rods is reliable, and the measurement results are stable in different environmental conditions. © 2023 Science Press. All rights reserved.
引用
收藏
相关论文
共 15 条
  • [1] FU Jiqing, AFA 3G Gd rod top end plug girth TIG wilding [J], Dongfang Electric Review, 18, 2, pp. 115-120, (2004)
  • [2] JIANG Huijing, YANG Xiaoyong, DING Ming, Et al., Analysis of leakage characteristics of helium turbine cycle in 10 MW high temperature gas cooled reactor[J], Chinese High Technology Letters, 25, 4, pp. 411-416, (2015)
  • [3] Rosenkrantz E, Ferrandis J Y, Leveque G, Et al., Ultrasonic measurement of gas pressure and composition for nuclear fuel rods[J], Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 603, 3, pp. 504-509, (2009)
  • [4] YANG Jiong, LEI Chunhui, MA Xianhong, Study on helium leak detection system for heat transfer tube of steam generator in nuclear power plant, Nuclear Power Engineering, 42, 6, pp. 219-224, (2021)
  • [5] Ferrandis J Y, Rosenkrantz E, Leveque G, Et al., Full-scale hot cell test of an acoustic sensor dedicated to measurement of the internal gas pressure and composition of a LWR nuclear fuel rod[J], IEEE Transactions on Nuclear Science, 60, 4, pp. 2894-2897, (2013)
  • [6] LIU Yandong, LIU Jinhua, GAO Zhenbo, Et al., Introduction to helium leakage detection methods for pressure vessels, Yizhong Technology, 4, (2002)
  • [7] JIANG Wei, MIAO Zhenyu, Research on leakage detection technology for high pressure heaters in nuclear power plants, Vacuum, 1, (2019)
  • [8] Kuang L, Jiang L, Ren L, Et al., Study on helium leak detecting for post irradiation fuel rods, International Conference on Nuclear Engineering, (2013)
  • [9] XUE Datong, XIAO Xiangzheng, WANG Genglin, Conditions for determining qualified leakage rate through fine leak detection of sealed devices by pressing helium and pre filling helium, Journal of Vacuum Science and Technology, 8, (2013)
  • [10] LI Tao, ZHANG Bin, LIU Lubei, Et al., Design and test of the helium pneumatic tuner based on 162.5 MHz superconducting cavity, Nuclear Techniques, 38, 10, (2015)