Switching Frequency Improvement of a High Speed on/off Valve Based on Pre-excitation Control Algorithm

被引:2
|
作者
Zhong, Qi [1 ,2 ,3 ]
Li, Xiaotian [1 ,3 ]
Mao, Yongxin [1 ,3 ]
Xu, Enguang [1 ,3 ]
Jia, Tiwei [1 ,3 ]
Li, Yanbiao [1 ,3 ]
Yang, Huayong [2 ]
机构
[1] Zhejiang Univ Technol, Coll Mech Engn, Hangzhou 310023, Peoples R China
[2] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Zhejiang, Peoples R China
[3] Zhejiang Univ Technol, Key Lab Special Purpose Equipment & Adv Proc Techn, Minist Educ, Hangzhou 310023, Peoples R China
基金
中国国家自然科学基金;
关键词
High speed on/off valve; Switching frequency; Pre-excitation; Dynamic performance; Switching duty ratio; RELIABILITY; LOSSES; POWER; LIFE;
D O I
10.1186/s10033-024-01072-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The high-speed on/off valve (HSV) serves as the fundamental component responsible for generating discrete fluids within digital hydraulic systems. As the switching frequency of the HSV increases, the properties of the generated discrete fluid approach those of continuous fluids. Therefore, a higher frequency response characteristic of HSV is the key to ensure the control accuracy of digital hydraulic systems. However, the current research mainly focuses on its dynamic performance, but neglect its FRC. This paper presents a theoretical analysis demonstrating that the FRC of the HSV can be enhanced by minimizing its switching time. The maximum switching frequency (MSF) is mainly determined by opening dynamic performance when HSV operates with low switching duty ratio (SDR), whereas the closing dynamic performance limits the MSF when HSV operates with high SDR. Building upon these findings, the pre-excitation control algorithm (PECA) is proposed to reduce the switching time of the HSV, and consequently enhance its FRC. Experimental results demonstrate that PECA shortens the opening delay time of HSV by 1.12 ms, the closing delay time by 2.54 ms, and the closing moving time by 0.47 ms in comparison to the existing advanced control algorithms. As a result, a larger MSF of 417 Hz and a wider controllable SDR range from 20% to 70% were achieved at a switching frequency of 250 Hz. Thus, the proposed PFCA in this paper has been verified as an effective and promising approach for enhancing the control performance of digital hydraulic systems.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Switching Frequency Improvement of a High Speed on/off Valve Based on Pre-excitation Control Algorithm
    Qi Zhong
    Xiaotian Li
    Yongxin Mao
    Enguang Xu
    Tiwei Jia
    Yanbiao Li
    Huayong Yang
    Chinese Journal of Mechanical Engineering, 2024, 37 (04) : 107 - 119
  • [2] Dynamic performance and temperature rising characteristic of a high-speed on/off valve based on pre-excitation control algorithm
    Zhong, Qi
    Xu, Enguang
    Xie, Geng
    Wang, Xiele
    Li, Yanbiao
    CHINESE JOURNAL OF AERONAUTICS, 2023, 36 (10) : 445 - 458
  • [3] Dynamic performance and temperature rising characteristic of a high-speed on/off valve based on pre-excitation control algorithm
    Qi ZHONG
    Enguang XU
    Geng XIE
    Xiele WANG
    Yanbiao LI
    Chinese Journal of Aeronautics , 2023, (10) : 445 - 458
  • [4] Dynamic performance and temperature rising characteristic of a high-speed on/off valve based on pre-excitation control algorithm
    Qi ZHONG
    Enguang XU
    Geng XIE
    Xiele WANG
    Yanbiao LI
    Chinese Journal of Aeronautics, 2023, 36 (10) : 445 - 458
  • [5] Fast dynamics and low power losses of high-speed solenoid valve based on optimized pre-excitation control algorithm
    Zhong, Qi
    Mao, Yong-xin
    Xu, En-guang
    Wang, Xie-le
    Li, Yan-biao
    Yang, Hua-yong
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47
  • [6] Three power sources excitation control strategy of high speed on/off valve based on current feedback
    Zhong Q.
    Zhang B.
    Hong H.-C.
    Yang H.-Y.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2018, 52 (01): : 8 - 15and58
  • [7] Analysis of Dynamic Characteristics and Power Losses of High Speed on/off Valve with Pre-Existing Control Algorithm
    Zhong, Qi
    Wang, Xiele
    Xie, Geng
    Yang, Huayong
    Yu, Cheng
    Xu, Enguang
    Li, Yanbiao
    ENERGIES, 2021, 14 (16)
  • [8] Linear Control Performance Improvement of High Speed On-Off Valve Controlled by PWM
    Meng, Aihong
    Song, Jian
    SAE INTERNATIONAL JOURNAL OF COMMERCIAL VEHICLES, 2015, 8 (02) : 283 - 292
  • [9] Maximal Pre-Excitation Based Algorithm for Localization of Manifest Accessory Pathways in Adults
    Pambrun, Thomas
    El Bouazzaoui, Rim
    Combes, Nicolas
    Combes, Stephane
    Sousa, Pedro
    Le Bloa, Mathieu
    Massoullie, Gregoire
    Cheniti, Ghassen
    Martin, Ruairidh
    Pillois, Xavier
    Duchateau, Josselin
    Sacher, Frederic
    Hocini, Meleze
    Jais, Pierre
    Derval, Nicolas
    Bortone, Agustin
    Boveda, Serge
    Denis, Arnaud
    Haissaguerre, Michel
    Albenque, Jean-Paul
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (08) : 1052 - 1061
  • [10] Switching response improvement of a high speed On/Off solenoid valve by using a 3 power source type valve driving circuit
    Lee, Ill-Yeong
    2006 IEEE International Conference on Industrial Technology, Vols 1-6, 2006, : 2179 - 2184