Switching Frequency Improvement of a High Speed on/off Valve Based on Pre-excitation Control Algorithm

被引:2
作者
Zhong, Qi [1 ,2 ,3 ]
Li, Xiaotian [1 ,3 ]
Mao, Yongxin [1 ,3 ]
Xu, Enguang [1 ,3 ]
Jia, Tiwei [1 ,3 ]
Li, Yanbiao [1 ,3 ]
Yang, Huayong [2 ]
机构
[1] Zhejiang Univ Technol, Coll Mech Engn, Hangzhou 310023, Peoples R China
[2] Zhejiang Univ, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Zhejiang, Peoples R China
[3] Zhejiang Univ Technol, Key Lab Special Purpose Equipment & Adv Proc Techn, Minist Educ, Hangzhou 310023, Peoples R China
基金
中国国家自然科学基金;
关键词
High speed on/off valve; Switching frequency; Pre-excitation; Dynamic performance; Switching duty ratio; RELIABILITY; LOSSES; POWER; LIFE;
D O I
10.1186/s10033-024-01072-y
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The high-speed on/off valve (HSV) serves as the fundamental component responsible for generating discrete fluids within digital hydraulic systems. As the switching frequency of the HSV increases, the properties of the generated discrete fluid approach those of continuous fluids. Therefore, a higher frequency response characteristic of HSV is the key to ensure the control accuracy of digital hydraulic systems. However, the current research mainly focuses on its dynamic performance, but neglect its FRC. This paper presents a theoretical analysis demonstrating that the FRC of the HSV can be enhanced by minimizing its switching time. The maximum switching frequency (MSF) is mainly determined by opening dynamic performance when HSV operates with low switching duty ratio (SDR), whereas the closing dynamic performance limits the MSF when HSV operates with high SDR. Building upon these findings, the pre-excitation control algorithm (PECA) is proposed to reduce the switching time of the HSV, and consequently enhance its FRC. Experimental results demonstrate that PECA shortens the opening delay time of HSV by 1.12 ms, the closing delay time by 2.54 ms, and the closing moving time by 0.47 ms in comparison to the existing advanced control algorithms. As a result, a larger MSF of 417 Hz and a wider controllable SDR range from 20% to 70% were achieved at a switching frequency of 250 Hz. Thus, the proposed PFCA in this paper has been verified as an effective and promising approach for enhancing the control performance of digital hydraulic systems.
引用
收藏
页数:13
相关论文
共 25 条
  • [1] Reliability and life study of hydraulic solenoid valve. Part 2: Experimental study
    Angadi, S. V.
    Jackson, R. L.
    Choe, Song-yul
    Flowers, G. T.
    Suhling, J. C.
    Chang, Young-Kwon
    Ham, Jung-Keol
    Bae, Jae-il
    [J]. ENGINEERING FAILURE ANALYSIS, 2009, 16 (03) : 944 - 963
  • [2] Reliability and life study of hydraulic solenoid valve. Part 1: A multi-physics finite element model
    Angadi, S. V.
    Jackson, R. L.
    Choe, Song-Yul
    Flowers, G. T.
    Suhling, J. C.
    Chang, Young-Kwon
    Ham, Jung-Keol
    [J]. ENGINEERING FAILURE ANALYSIS, 2009, 16 (03) : 874 - 887
  • [3] Breidi F, 2014, PROCEEDINGS OF THE ASME/BATH SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, 2014
  • [4] Energy-saving Driver Circuit of High-speed Solenoid Valve Based on Soft-switch Technology
    Cai Sheng-nian
    Jiao Yu
    Xu Cheng-tao
    Liang Yu
    Qin Ran
    [J]. PROCEEDINGS OF THE 2012 SECOND INTERNATIONAL CONFERENCE ON INSTRUMENTATION & MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC 2012), 2012, : 598 - 601
  • [5] [陈龙 Chen Long], 2018, [农业机械学报, Transactions of the Chinese Society for Agricultural Machinery], V49, P403
  • [6] Gao Qiang, 2019, Journal of Beijing University of Aeronautics and Astronautics, V45, P1129, DOI 10.13700/j.bh.1001-5965.2018.0565
  • [7] Ill-Yeong Lee, 2007, IEEE International Conference on Information Technology, P1823
  • [8] Reconfigurable wideband filtering power divider with good isolations performance
    Lei, Peng
    Wang, Xiaochuan
    Lv, Wenzhong
    Yang, Jiaqing
    Zhang, Meng
    Liu, Ya-wen
    [J]. ELECTROMAGNETICS, 2022, 42 (07) : 513 - 521
  • [9] Linjama M., 2003, The Eighth Scandinavian International Conference on Fluid Power, Tampere, Finland, P347
  • [10] Dynamic Performance Improvement of Solenoid Screw-In Cartridge Valve Using a New Hybrid Voltage Control
    Liu, Zengguang
    Li, Linfei
    Yue, Daling
    Wei, Liejiang
    Liu, Chao
    Zuo, Xiukun
    [J]. MACHINES, 2022, 10 (02)