The impact of introducing deep learning based [18F]FDG PET denoising on EORTC and PERCIST therapeutic response assessments in digital PET/CT

被引:1
|
作者
Weyts, Kathleen [1 ]
Lequesne, Justine [2 ]
Johnson, Alison [3 ]
Curcio, Hubert [3 ]
Parzy, Aurelie [3 ]
Coquan, Elodie [3 ]
Lasnon, Charline [1 ,4 ]
机构
[1] UNICANCER, Nucl Med Dept, Francois Baclesse Comprehens Canc Ctr, BP 45026,3 Ave Gen Harris, F-14076 Caen, France
[2] UNICANCER, Francois Baclesse Comprehens Canc Ctr, Biostat Dept, Caen, France
[3] UNICANCER, Francois Baclesse Comprehens Canc Ctr, Med Oncol Dept, Caen, France
[4] Normandy Univ, UNICAEN, INSERM 1086, ANTICIPE, Caen, France
来源
EJNMMI RESEARCH | 2024年 / 14卷 / 01期
关键词
Artificial intelligence; Deep learning; EORTC; PERCIST; PET; F-18]FDG; POSITRON-EMISSION-TOMOGRAPHY; CRITERIA; PROMISE; SUV;
D O I
10.1186/s13550-024-01128-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background [F-18]FDG PET denoising by SubtlePET (TM) using deep learning artificial intelligence (AI) was previously found to induce slight modifications in lesion and reference organs' quantification and in lesion detection. As a next step, we aimed to evaluate its clinical impact on [F-18]FDG PET solid tumour treatment response assessments, while comparing "standard PET" to "AI denoised half-duration PET" ("AI PET") during follow-up. Results 110 patients referred for baseline and follow-up standard digital [F-18]FDG PET/CT were prospectively included. "Standard" EORTC and, if applicable, PERCIST response classifications by 2 readers between baseline standard PET1 and follow-up standard PET2 as a "gold standard" were compared to "mixed" classifications between standard PET1 and AI PET2 (group 1; n = 64), or between AI PET1 and standard PET2 (group 2; n = 46). Separate classifications were established using either standardized uptake values from ultra-high definition PET with or without AI denoising (simplified to "UHD") or EANM research limited v2 (EARL2)-compliant values (by Gaussian filtering in standard PET and using the same filter in AI PET). Overall, pooling both study groups, in 11/110 (10%) patients at least one EORTCUHD or EARL2 or PERCISTUHD or EARL2 mixed vs. standard classification was discordant, with 369/397 (93%) concordant classifications, unweighted Cohen's kappa = 0.86 (95% CI: 0.78-0.94). These modified mixed vs. standard classifications could have impacted management in 2% of patients. Conclusions Although comparing similar PET images is preferable for therapy response assessment, the comparison between a standard [F-18]FDG PET and an AI denoised half-duration PET is feasible and seems clinically satisfactory.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Deep Learning Denoising Improves and Homogenizes Patient [18F]FDG PET Image Quality in Digital PET/CT
    Weyts, Kathleen
    Quak, Elske
    Licaj, Idlir
    Ciappuccini, Renaud
    Lasnon, Charline
    Corroyer-Dulmont, Aurelien
    Foucras, Gauthier
    Bardet, Stephane
    Jaudet, Cyril
    DIAGNOSTICS, 2023, 13 (09)
  • [2] [18F]FDG PET/CT criteria for treatment response assessment: EORTC and beyond
    Miceli, Alberto
    Jonghi-Lavarini, Lorenzo
    Santo, Giulia
    Cassarino, Gianluca
    Linguanti, Flavia
    Gazzilli, Maria
    Cimino, Alessandra
    Buschiazzo, Ambra
    Sorbello, Stefania
    Abenavoli, Elisabetta
    Conte, Miriam
    Pepponi, Miriam
    Di Dato, Rossella
    Rondini, Maria
    Salis, Roberto
    Tardelli, Elisa
    Nicolini, Denise
    Laudicella, Riccardo
    La Torre, Flavia
    Nappi, Anna Giulia
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (05) : 421 - 437
  • [3] [18F]FDG PET/CT criteria for treatment response assessment: EORTC and beyond
    Alberto Miceli
    Lorenzo Jonghi-Lavarini
    Giulia Santo
    Gianluca Cassarino
    Flavia Linguanti
    Maria Gazzilli
    Alessandra Cimino
    Ambra Buschiazzo
    Stefania Sorbello
    Elisabetta Abenavoli
    Miriam Conte
    Miriam Pepponi
    Rossella Di Dato
    Maria Rondini
    Roberto Salis
    Elisa Tardelli
    Denise Nicolini
    Riccardo Laudicella
    Flavia La Torre
    Anna Giulia Nappi
    Clinical and Translational Imaging, 2023, 11 : 421 - 437
  • [4] Artificial intelligence-based PET denoising could allow a two-fold reduction in [18F]FDG PET acquisition time in digital PET/CT
    Weyts, Kathleen
    Lasnon, Charline
    Ciappuccini, Renaud
    Lequesne, Justine
    Corroyer-Dulmont, Aurelien
    Quak, Elske
    Clarisse, Benedicte
    Roussel, Laurent
    Bardet, Stephane
    Jaudet, Cyril
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (11) : 3750 - 3760
  • [5] Artificial intelligence-based PET denoising could allow a two-fold reduction in [18F]FDG PET acquisition time in digital PET/CT
    Kathleen Weyts
    Charline Lasnon
    Renaud Ciappuccini
    Justine Lequesne
    Aurélien Corroyer-Dulmont
    Elske Quak
    Bénédicte Clarisse
    Laurent Roussel
    Stéphane Bardet
    Cyril Jaudet
    European Journal of Nuclear Medicine and Molecular Imaging, 2022, 49 : 3750 - 3760
  • [6] Interchangeability of radiomic features between [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Diem Vuong
    Tanadini-Lang, Stephanie
    Huellner, Martin W.
    Veit-Haibach, Patrick
    Unkelbach, Jan
    Andratschke, Nicolaus
    Kraft, Johannes
    Guckenberger, Matthias
    Bogowicz, Marta
    MEDICAL PHYSICS, 2019, 46 (04) : 1677 - 1685
  • [7] Digital PET/CT allows for shorter acquisition protocols or reduced radiopharmaceutical dose in [18F]-FDG PET/CT
    Alberts, Ian
    Sachpekidis, Christos
    Prenosil, George
    Viscione, Marco
    Bohn, Karl Peter
    Mingels, Clemens
    Shi, Kuangyu
    Ashar-Oromieh, Ali
    Rominger, Axel
    ANNALS OF NUCLEAR MEDICINE, 2021, 35 (04) : 485 - 492
  • [8] A deep learning model for generating [18F]FDG PET Images from early-phase [18F]Florbetapir and [18F]Flutemetamol PET images
    Sanaat, Amirhossein
    Boccalini, Cecilia
    Mathoux, Gregory
    Perani, Daniela
    Frisoni, Giovanni B.
    Haller, Sven
    Montandon, Marie-Louise
    Rodriguez, Cristelle
    Giannakopoulos, Panteleimon
    Garibotto, Valentina
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 (12) : 3518 - 3531
  • [9] The Impact That Number of Analyzed Metastatic Breast Cancer Lesions Has on Response Assessment by 18F-FDG PET/CT Using PERCIST
    Pinker, Katja
    Riedl, Christopher C.
    Ong, Leonard
    Jochelson, Maxine
    Ulaner, Gary A.
    McArthur, Heather
    Dickler, Maura
    Gonen, Mithad
    Weber, Wolfgang A.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1102 - 1104
  • [10] The Role of [18F]FDG PET/CT in Monitoring of Therapy Response in Lung Cancer
    Ayeni, Akinwale
    Evbuomwan, Osayande
    Vangu, Mboyo-Di-Tamba Willy
    SEMINARS IN NUCLEAR MEDICINE, 2025, 55 (02) : 175 - 189