WIND FORCES ON PHOTOVOLTAIC PANELS MOUNTED ON GABLE ROOF WITH JAPANESE ROOF TILES

被引:0
作者
Murakami T. [1 ]
Maruyama T. [2 ]
机构
[1] Kyoto University, Yanegiken Co., Ltd.
[2] Disaster Prevention Research Institute, Kyoto University
来源
Journal of Structural and Construction Engineering | 2024年 / 89卷 / 815期
关键词
Gable roof; Japanese roof tile; Photovoltaic panel; Wind force; Wind tunnel test;
D O I
10.3130/aijs.89.1
中图分类号
学科分类号
摘要
The wind tunnel test examines the wind force using gable roof house models with Japanese roof tiles, which is not included in JIS C8955 as the design standard for photovoltaic panels. The test results show the maximum peak wind force for the panels on Japanese roof tiles in all wind directions is within that for the panels on flat surface roof in JIS C8955. On the other hand, the peak wind force on a panel on Japanese roof tiles is greater than that on the panel on flat surface roof in specific wind directions. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:1 / 9
页数:8
相关论文
共 11 条
[1]  
Prime Minister of Japan and His Cabinet: Policy Speech by the Prime Minister to the 203rd Session of the Diet, (2020)
[2]  
Infrastructure, Transport and Tourism, Ministry of Economy, Trade and Industry, Ministry of the Environment: Datsutansoshakainimuketajuutakukentikubutsuniokerushouenetaisaku nadonoarikatasusumekata (Energy Conservation Measures in Housing and Buildings for a Decarbonized Society), (2021)
[3]  
Load design guide on structures for photovoltaic array, (2017)
[4]  
Takamori Koji, Nakagawa Naohiro, Yamamoto Manabu, Okuda Yasuo, Taniguchi Tetsuro, Nakamura Osamu, Study on design force coefficients for photovoltaic modules installed on low-rise building, AIJ Journal of Technology and Design, 21, 47, pp. 67-70, (2015)
[5]  
Okada Hajime, Ohkuma Takeshi, Katagiri Junji, Study on Estimation of Wind Pressure under Roof Tiles, Journal of Structural and Construction Engineering (Transactions of AIJ), 73, 633, pp. 1943-1950, (2008)
[6]  
Ito Shinji, Okuda Yasuo, Kikitsu Hitomitsu, Study on Peak Wind Force Coefficients on Gable Roof Tiles using Wind Tunnel Model with Underside and Ridge Tiles, Proceedings of The 22nd National Symposium on Wind Engineering, pp. 161-166, (2012)
[7]  
Oh J.H., Kopp G.A., Modelling of spatially and temporally-varying cavity pressures in air-permeable, double-layer roof systems, Building and Environment, 82, pp. 135-150, (2014)
[8]  
Yambe Tetsuo, Yamamoto Atsushi, Sato Kosuke, Uematsu Yasushi, Wind Loads on Photovoltaic Panels Mounted on a Sloped Roof to The Edges, AIJ Journal of Technology and Design, 27, 67, pp. 1177-1182
[9]  
Kawai Hiromasa, Correction of Distortion Effects Caused by Tubing System by Digital Filtering Method, Summaries of Technical Papers of Annual Meeting, (1987)
[10]  
Recommendations for Loads on Buildings, (2015)