New dynamic suture material for tendon transfer surgeries in the upper extremity - a biomechanical comparative analysis

被引:1
作者
Pastor, Tatjana [1 ,2 ]
Zderic, Ivan [1 ]
Dhillon, Mehar [1 ]
Gueorguiev, Boyko [1 ]
Richards, R. Geoff [1 ]
Pastor, Torsten [3 ]
Vogelin, Esther [2 ]
机构
[1] AO Res Inst Davos, CH-7270 Davos, Switzerland
[2] Univ Bern, Inselspital, Dept Plast & Hand Surg, Univ Hosp Bern, Bern, Switzerland
[3] Lucerne Cantonal Hosp, Dept Orthopaed & Trauma Surg, Luzern, Switzerland
关键词
Tendon transfer; FiberWire; Dynacord; Tendon approximation; Early rehabilitation; Biomechanics; POLLICIS LONGUS TENDON; SUPERFICIALIS TENDON; PULVERTAFT WEAVE; FLEXOR; GRAFT; THUMB; RECONSTRUCTION; RESTORATION; INJURIES; RUPTURE;
D O I
10.1007/s00402-024-05322-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Early mobilization after tendon surgery is crucial to avoid commonly observed postoperative soft tissue adhesions. Recently, a new suture was introduced (DYNACORD; DC) with a salt-infused silicone core designed to minimize laxity and preserve consistent tissue approximation in order to avoid gap formation and allow early mobilization. Aims To compare the biomechanical competence of DC against a conventional high strength suture (FiberWire; FW) in a human cadaveric tendon transfer model with an early rehabilitation protocol. Methods Sixteen tendon transfers (flexor digitorum superficialis (FDS) IV to flexor pollicis longus (FPL)) were performed in 8 pairs human cadaveric forearms using either DC or FW. Markings were set 0.8 cm proximally and 0.7 cm distally to the level of the interweaving zone of the transfer. All specimens underwent repetitive thumb flexion against resistance in 9 intermittent series of 300 cycles each, simulating an aggressive postoperative rehabilitation protocol. After each series, the distance of the proximal marker to the interweaving zone (proximal), the length of the interweaving zone (intermediate) and the distance of the distal marker to the interweaving zone (distal) were measured. Results Pooled data over all nine series, normalized to the immediate postoperative status, demonstrated no significant differences between FW and DC (p >= 0.355) for the proximal and distal markers. However, at the intermediate zone, DC was associated with significant length shortening (p < 0.001) compared to FW without significant length changes (p = 0.351). Load to catastrophic failure demonstrated significant higher forces in FW (p = 0.011). Nevertheless, due to failure mainly proximal or distal of the transfer zone, these loads are not informative. Conclusion From a biomechanical perspective, DC preserved tissue approximation and might be considered as a valid alternative to conventional high-strength sutures in tendon transfer surgery. DC might allow for a shorter interweaving zone and a more aggressive early postoperative rehabilitation program, possibly avoiding commonly observed postoperative soft tissue adhesions and stiffness.
引用
收藏
页码:2905 / 2914
页数:10
相关论文
共 34 条
  • [1] Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius
    Bell, JSP
    Wollstein, R
    Citron, ND
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 225 - 226
  • [2] Mechanical Strength of the Side-to-Side Versus Pulvertaft Weave Tendon Repair
    Brown, Stephen H. M.
    Hentzen, Eric R.
    Kwan, Alan
    Ward, Samuel R.
    Friden, Jan
    Lieber, Richard L.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (04): : 540 - 545
  • [3] The strengths of one-, two-, and three-weave Pulvertaft tendon repairs
    Choke, Abby
    Rung, Wong Yoke
    McGrouther, Duncan A.
    Bin Abd Razak, Hamid Rahmatullah
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (10) : 1051 - 1054
  • [4] Biomechanical assessment of a novel tendon junction
    Crook, T.
    Tawfik, J.
    Bertollo, N.
    Wheen, D. J.
    Scougall, P. J.
    Walsh, W. R.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 795 - 800
  • [5] In vitro biomechanical study to compare the double-loop technique with the Pulvertaft weave for tendon anastomosis
    De Smet, Luc
    Schollen, Wilfried
    Degreef, Ilse
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2008, 42 (06): : 305 - 307
  • [6] Osteosynthesis of distal radial fractures with a volar locking screw plate system
    Drobetz, H
    Kutscha-Lissberg, E
    [J]. INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) : 1 - 6
  • [7] Duncan Scott F M, 2007, Am J Orthop (Belle Mead NJ), V36, P669
  • [8] EBELIN M, 1985, Annales de Chirurgie de la Main, V4, P111, DOI 10.1016/S0753-9053(85)80121-6
  • [9] FLEXOR TENDON RUPTURES IN PATIENTS WITH RHEUMATOID-ARTHRITIS
    ERTEL, AN
    MILLENDER, LH
    NALEBUFF, E
    MCKAY, D
    LESLIE, B
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (06): : 860 - 866
  • [10] Suture constructs for rehabilitation using early active motion after tendon transfer surgery
    Fitzgerald, Michael G.
    Hammond, Max A.
    Yang, Patrick W.
    Merrell, Gregory A.
    [J]. JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 931 - 935