Prospective evaluation of automated vascular analysis for ilio-femoral artery lesions before and after percutaneous endovascular aortic repair

被引:0
作者
Goto, Takasumi [1 ]
Fujimura, Hironobu [1 ]
Iida, Takuma [1 ]
Horikawa, Kohei [1 ]
Shintani, Takashi [2 ]
Shibuya, Takashi [3 ]
Sakaniwa, Ryoto [4 ]
Miyagawa, Shigeru [3 ]
机构
[1] Toyonaka City Hosp, Dept Cardiovasc Surg, 4-14-1,Shibahara, Toyonaka, Osaka 5608565, Japan
[2] Nippon Life Hosp, Dept Cardiovasc Surg, Osaka, Japan
[3] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Osaka, Japan
[4] Osaka Univ, Grad Sch Med, Dept Social Med, Publ Hlth, Osaka, Japan
关键词
Ankle brachial index; Endovascular aneurysm repair; Femoral artery; Fistula; Haematoma; Iliac artery; Leg; Surgical wound infection; Tomography; ANEURYSM-REPAIR; CLOSURE DEVICES; RISK-FACTORS; II ENDOLEAK; COMPLICATIONS; SAFETY;
D O I
10.1186/s13019-024-03013-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThis study was conducted to evaluate the differences between pre- and postoperative access conditions in percutaneous endovascular aortic repair (PEVAR).MethodsBetween December 2021 and October 2023, PEVAR was performed on 61 patients using the Perclose ProStyle (Abbott Vascular). Enhanced computed tomography and ankle-brachial index tests were performed preoperatively and postoperatively. The inner diameter and area of the iliofemoral artery were automatically measured, and the pre- and postoperative values were compared (114 legs). The same analysis was performed on 12 legs with previous groin operations; open surgical EVAR was performed in 9 legs, an endarterectomy of the femoral artery in 1, and a femoropopliteal bypass in the other leg.ResultsAll patients were discharged without surgical site infections, lymphatic fistulas, or retroperitoneal haematomas. There were no significant differences between the pre-and postoperative inner diameter and inner area of the external iliac artery and common femoral artery. There were no significant differences between the preoperative and postoperative ankle-brachial index tests. In 12 legs with a previous groin operation, the postoperative ankle-brachial index tests and inner diameter and area of the external iliac artery and common femoral artery were statistically equal to the preoperative values.ConclusionsThis study can support the safety of percutaneous endovascular aortic repair, even in patients with redo groin operations.
引用
收藏
页数:7
相关论文
共 21 条
[1]   Selective Use of Percutaneous Endovascular Aneurysm Repair in Women Leads to Fewer Groin Complications [J].
Al-Khatib, Weesam K. ;
Zayed, Mohamed A. ;
Harris, E. John ;
Dalman, Ronald L. ;
Lee, Jason T. .
ANNALS OF VASCULAR SURGERY, 2012, 26 (04) :476-482
[2]   Midterm outcome of endovascular abdominal aortic aneurysm repair in octogenarians: A single institution's experience [J].
Biebl, M ;
Lau, LL ;
Hakaim, AG ;
Oldenburg, WA ;
Klocker, J ;
Neuhauser, B ;
McKinney, JM ;
Paz-Fumagalli, R .
JOURNAL OF VASCULAR SURGERY, 2004, 40 (03) :435-442
[3]   Safety and Efficacy of Totally Percutaneous Access Compared With Open Femoral Exposure for Endovascular Aneurysm Repair: A Meta-analysis [J].
Cao, Zhanjiang ;
Wu, Weiwei ;
Zhao, Keqiang ;
Zhao, Junlai ;
Yang, Yu ;
Jiang, Chao ;
Zhu, Rongrong .
JOURNAL OF ENDOVASCULAR THERAPY, 2017, 24 (02) :246-253
[4]   Successful chimney endovascular aortic repair with reconstruction of three visceral branches for huge saccular juxtarenal abdominal aortic aneurysm after trans-thoracoabdominal esophagectomy [J].
Goto, Takasumi ;
Fujimura, Hironobu ;
Shintani, Takashi ;
Shibuya, Takashi .
JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
[5]   Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised controlled trial [J].
Greenhalgh, RM ;
Brown, LC ;
Epstein, D ;
Kwong, GPS ;
Powell, JT ;
Sculpher, MJ ;
Thompson, SG .
LANCET, 2005, 365 (9478) :2179-2186
[6]   Quantified Aortic Luminal Irregularity as a Predictor of Complications and Prognosis After Endovascular Aneurysm Repair [J].
Hosaka, Akihiro ;
Kato, Masaaki ;
Motoki, Manabu ;
Sugai, Hiroko ;
Okubo, Nobukazu .
MEDICINE, 2016, 95 (09)
[7]   Safety and utility of total percutaneous endovascular aortic repair with a single Perclose ProGlide closure device [J].
Ichihashi, Taku ;
Ito, Tsuyoshi ;
Kinoshita, Yoshihisa ;
Suzuki, Takahiko ;
Ohte, Nobuyuki .
JOURNAL OF VASCULAR SURGERY, 2016, 63 (03) :585-588
[8]   Impact of the Patency of Inferior Mesenteric Artery on 7-Year Outcomes After Endovascular Aneurysm Repair [J].
Ide, Toru ;
Shimamura, Kazuo ;
Kuratani, Toru ;
Shijo, Takayuki ;
Sakaniwa, Ryoto ;
Watanabe, Yoshiki ;
Maeda, Koichi ;
Masada, Kenta ;
Yamashita, Kizuku ;
Matsumoto, Ryota ;
Miyagawa, Shigeru .
JOURNAL OF ENDOVASCULAR THERAPY, 2024, 31 (03) :371-380
[9]   Risk Analysis of Aneurysm Sac Enlargement Caused by Type II Endoleak after Endovascular Aortic Repair [J].
Ide, Toru ;
Masada, Kenta ;
Kuratani, Toru ;
Sakaniwa, Ryoto ;
Shimamura, Kazuo ;
Kin, Keiwa ;
Watanabe, Yoshiki ;
Matsumoto, Ryota ;
Sawa, Yoshiki .
ANNALS OF VASCULAR SURGERY, 2021, 77 :208-216
[10]   Open versus Endovascular Repair of Abdominal Aortic Aneurysm [J].
Lederle, Frank A. ;
Kyriakides, Tassos C. ;
Stroupe, Kevin T. ;
Freischlag, Julie A. ;
Padberg, Frank T., Jr. ;
Matsumura, Jon S. ;
Huo, Zhiping ;
Johnson, Gary R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (22) :2126-2135