A microfluidic-based quantitative analysis system for the multiplexed genetic diagnosis of human viral infections using colorimetric loop-mediated isothermal amplification

被引:2
|
作者
Natsuhara, Daigo [1 ]
Miyajima, Akira [1 ]
Bussho, Tomoya [1 ]
Okamoto, Shunya [1 ]
Nagai, Moeto [1 ,2 ]
Ihira, Masaru [3 ]
Shibata, Takayuki [1 ]
机构
[1] Toyohashi Univ Technol, Dept Mech Engn, Toyohashi, Aichi 4418580, Japan
[2] Toyohashi Univ Technol, Inst Res Next Generat Semicond & Sensing Sci IRES2, Toyohashi, Aichi 4418580, Japan
[3] Fujita Hlth Univ, Fac Clin Sci Biol Monitoring, Toyoake, Aichi 4701192, Japan
关键词
LAMP; INFLUENZA; COLOR;
D O I
10.1039/d4an00215f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a microfluidic-based system utilizing colorimetric loop-mediated isothermal amplification (LAMP) is introduced for the quantitative analysis of nucleic acid targets. This system offers a user-friendly and cost-effective platform for the multiplexed genetic diagnosis of various infectious diseases across multiple samples. It includes time-lapse imaging equipment for capturing images of the microfluidic device during the LAMP assay and a hue-based quantitative analysis software to analyze the LAMP reaction, streamlining diagnostic procedures. An electric pipette was used to simplify the loading of samples and LAMP reagents into the device, allowing easy operation even by untrained individuals. The hue-based analysis software employs efficient image processing and post-processing techniques to calculate DNA amplification curves based on color changes in multiple reaction chambers. This software automates several tasks, such as identifying reaction chamber areas from time-lapse images, quantifying color information within each chamber, correcting baselines of DNA amplification curves, fitting experimental data to theoretical curves, and determining the threshold time for each curve. To validate the developed system, conventional off-chip LAMP assays were conducted with a 25 mu L reaction mixture in 0.2 mL polymerase chain reaction (PCR) tubes using a real-time turbidimeter. The results indicated that the threshold time obtained using the colorimetric LAMP assay in the developed system is comparable to that obtained with real-time turbidity measurements in PCR tubes, demonstrating the system's capability for quantitative analysis of target nucleic acids, including those from human herpesviruses. We developed a microfluidic-based system employing the colorimetric loop-mediated isothermal amplification for the quantitative analysis of nucleic acid targets.
引用
收藏
页码:3335 / 3345
页数:11
相关论文
共 50 条
  • [21] A self-contained microfluidic in-gel loop-mediated isothermal amplification for multiplexed pathogen detection
    Chen, Chen
    Liu, Pian
    Zhao, Xing
    Du, Wei
    Feng, Xiaojun
    Liu, Bi-Feng
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 239 : 1 - 8
  • [22] Diagnostic Host Gene Expression Analysis by Quantitative Reverse Transcription Loop-Mediated Isothermal Amplification to Discriminate between Bacterial and Viral Infections
    Remmel, Melissa C.
    Coyle, Sabrina M.
    Eshoo, Mark W.
    Sweeney, Timothy E.
    Rawling, David C.
    CLINICAL CHEMISTRY, 2022, 68 (04) : 550 - 560
  • [23] Rapid isolation and detection of aquaculture pathogens in an integrated microfluidic system using loop-mediated isothermal amplification
    Chang, Wen-Hsin
    Yang, Sung-Yi
    Wang, Chih-Hung
    Tsai, Ming-An
    Wang, Pei-Chi
    Chen, Tzong-Yueh
    Chen, Shih-Chu
    Lee, Gwo-Bin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 180 : 96 - 106
  • [24] Optimization of the Amplicons Detection System of Loop-Mediated Isothermal Amplification on Microfluidic Compact Disk
    Uddin, Shah Mukim
    Ibrahim, Fatimah
    Cho, Jongman
    Thong, Kwai Lin
    INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS, 2019, 64 : 7 - 12
  • [25] Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue
    Goto, Motoki
    Honda, Eiichi
    Ogura, Atsuo
    Nomoto, Akio
    Hanaki, Ken-Ichi
    BIOTECHNIQUES, 2009, 46 (03) : 167 - +
  • [26] A digital microfluidic system for loop-mediated isothermal amplification and sequence specific pathogen detection
    Liang Wan
    Tianlan Chen
    Jie Gao
    Cheng Dong
    Ada Hang-Heng Wong
    Yanwei Jia
    Pui-In Mak
    Chu-Xia Deng
    Rui P. Martins
    Scientific Reports, 7
  • [27] A digital microfluidic system for loop-mediated isothermal amplification and sequence specific pathogen detection
    Wan, Liang
    Chen, Tianlan
    Gao, Jie
    Dong, Cheng
    Wong, Ada Hang-Heng
    Jia, Yanwei
    Mak, Pui-In
    Deng, Chu-Xia
    Martins, Rui P.
    SCIENTIFIC REPORTS, 2017, 7
  • [28] Loop-Mediated Isothermal Amplification as Point-of-Care Diagnosis for Neglected Parasitic Infections
    Avendano, Catalina
    Alfonso Patarroyo, Manuel
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (21) : 1 - 32
  • [29] Recent advances in centrifugal microfluidic chip-based loop-mediated isothermal amplification
    Xiao, Bin
    Zhao, Ruiming
    Wang, Nan
    Zhang, Juan
    Sun, Xiaoyun
    Chen, Ailiang
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2023, 158
  • [30] A microfluidic-chip-based system with loop-mediated isothermal amplification for rapid and parallel detection of Trichomonas vaginalis and human papillomavirus
    Mao, Zeyin
    Deng, Anni
    Jin, Xiangyu
    Li, Meng
    Lv, Wenqi
    Huang, Leyang
    Zhong, Hao
    Yang, Han
    Wang, Shihong
    Shi, Yixuan
    Zhang, Lei
    Liao, Qinping
    Huang, Guoliang
    ANALYST, 2023, 148 (19) : 4820 - 4828