Effect analysis of rotor interturn short circuit fault detection for pumped storage unit under multiple working conditions

被引:0
|
作者
Fan X. [1 ]
Wu Y. [1 ]
Lu W. [2 ]
机构
[1] Hebei Key Laboratory of Green and Efficient New Electrical Materials and Equipment, North China Electric Power University, Baoding
[2] Pumped-storage Technological & Economic Research Institute State Grid Xinyuan Company Ltd., Beijing
来源
Dianji yu Kongzhi Xuebao/Electric Machines and Control | 2023年 / 27卷 / 04期
关键词
characteristic of harmonic; induced voltage; pumped storage unit; rotor winding inter-turn short circuit; U-type detection coil;
D O I
10.15938/j.emc.2023.04.003
中图分类号
学科分类号
摘要
The rotor winding inter-turn short circuit fault forms an unbalanced magnetic pull inside the pumped storage unit, which can lead to severe vibration of the unit. It is necessary to accurately and real-time detect the fault. The U-type detection coil installed on the stator core of the unit is used to detect the inter-turn short-circuit fault of the rotor in view of the variable operating conditions of the pumped storage unit. Taking a 322 MW pumped storage unit in a hydropower station as an example, the typical working conditions of no-load condition, rated load, power generation phase modulation, motor load and electric modulation were simulated by finite element software. The inter-turn short-circuit fault of the rotor winding in different degrees was simulated. The results show that the fractional harmonics appear in the induced electromotive force of the detection coil after the fault, and the amplitude increases with the rise of the fault degree. It is proved that the U-type detection coil can effectively reflect the inter-turn short circuit fault of rotor winding under multiple working conditions of pumped storage units. Therefore, the U-type detection coil method is suitable for online diagnosis of inter-turn short circuit fault of rotor winding of pumped storage units. © 2023 Editorial Department of Electric Machines and Control. All rights reserved.
引用
收藏
页码:23 / 33
页数:10
相关论文
共 30 条
  • [1] ZUO Cheng, LI Jiming, WU Zhifeng, The analysis and countermeasure of the typical fault cause of rotor magnetic pole in pumped storage unit [ J ], Hydropower and Pumped Storage, 4, 5, (2018)
  • [2] (2018)
  • [3] WU Yucai, LI Yonggang, FENG Wenzong, Et al., Analysis on unbalanced magnetic pull generated by turn-to-turn short circuit of rotor windings within turbine generator [J], Electric Machines and Control, 19, 3, (2015)
  • [4] WU Yucai, LI Yonggang, LI Heming, Et al., The generator rotor UMP under composite faults [ J], Electric Machines and Control, 17, 6, (2013)
  • [5] FAN Shiying, Analysis of stability for large and medium-sized hydro-generating unit [ J], Proceedings of the CSEE, 32, 9, (2012)
  • [6] HAO Liangliang, SUN Yuguang, QIU Arui, Et al., The steady-state fault characteristics of a large hydro-generator with inter-turn short circuit of field windings [J], Automation of Electric Power System, 35, 4, (2011)
  • [7] (2015)
  • [8] WANG Lin, CHEUNG Richard W, MA Zhiyun, Et al., Finite-element analysis of unbalanced magnetic pull in a large hydro-generator under practical operations[J], IEEE Transactions on Magnetics, 44, 6, (2008)
  • [9] ZHU Honglei, Inspection and treatment of interturn short circuit of hydraulic turbine generator magnetic pole coils, Explosion-proof Electric Machine, 47, 3, (2012)
  • [10] YAO Yong, New measurement methods of short circuit between the windings of the rotor of hydrogenerator, Water Power, 3, (2003)