A systematic literature review: deep learning techniques for synthetic medical image generation and their applications in radiotherapy

被引:12
作者
Sherwani, Moiz Khan [1 ]
Gopalakrishnan, Shyam [1 ]
机构
[1] Univ Copenhagen, Globe Inst, Sect Evolutionary Hologen, Copenhagen, Denmark
来源
FRONTIERS IN RADIOLOGY | 2024年 / 4卷
基金
新加坡国家研究基金会;
关键词
deep learning; convolutional neural network; radiotherapy; synthetic CT; photon therapy; proton therapy; generative adversarial network; LOW-DOSE CT; CONVOLUTIONAL NEURAL-NETWORK; HEAD-AND-NECK; COMPUTED-TOMOGRAPHY GENERATION; CONE-BEAM CT; GUIDED ADAPTIVE RADIOTHERAPY; ADVERSARIAL NETWORK; ATTENUATION CORRECTION; PROTON THERAPY; ARTIFICIAL-INTELLIGENCE;
D O I
10.3389/fradi.2024.1385742
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this systematic review is to determine whether Deep Learning (DL) algorithms can provide a clinically feasible alternative to classic algorithms for synthetic Computer Tomography (sCT). The following categories are presented in this study: MR-based treatment planning and synthetic CT generation techniques. Generation of synthetic CT images based on Cone Beam CT images. Low-dose CT to High-dose CT generation. Attenuation correction for PET images. To perform appropriate database searches, we reviewed journal articles published between January 2018 and June 2023. Current methodology, study strategies, and results with relevant clinical applications were analyzed as we outlined the state-of-the-art of deep learning based approaches to inter-modality and intra-modality image synthesis. This was accomplished by contrasting the provided methodologies with traditional research approaches. The key contributions of each category were highlighted, specific challenges were identified, and accomplishments were summarized. As a final step, the statistics of all the cited works from various aspects were analyzed, which revealed that DL-based sCTs have achieved considerable popularity, while also showing the potential of this technology. In order to assess the clinical readiness of the presented methods, we examined the current status of DL-based sCT generation.
引用
收藏
页数:28
相关论文
共 269 条
[1]   A deep learning-based whole-body solution for PET/MRI attenuation correction [J].
Ahangari, Sahar ;
Olin, Anders Beck ;
Federspiel, Marianne Kinggard ;
Jakoby, Bjoern ;
Andersen, Thomas Lund ;
Hansen, Adam Espe ;
Fischer, Barbara Malene ;
Andersen, Flemming Littrup .
EJNMMI PHYSICS, 2022, 9 (01)
[2]   Dosimetry-Driven Quality Measure of Brain Pseudo Computed Tomography Generated From Deep Learning for MRI-Only Radiation Therapy Treatment Planning [J].
Andres, Emilie Alvarez ;
Fidon, Lucas ;
Vakalopoulou, Maria ;
Lerousseau, Marvin ;
Carre, Alexandre ;
Sun, Roger ;
Klausner, Guillaume ;
Ammari, Samy ;
Benzazon, Nathan ;
Reuze, Sylvain ;
Estienne, Theo ;
Niyoteka, Stephane ;
Battistella, Enzo ;
Rouyar, Angela ;
Noel, Georges ;
Beaudre, Anne ;
Dhermain, Frederic ;
Deutsch, Eric ;
Paragios, Nikos ;
Robert, Charlotte .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03) :813-823
[3]  
[Anonymous], 2010, P 27 INT C MACH LEAR, DOI 10.5555/3104322.3104425
[4]   MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers [J].
Arabi, Hossein ;
Zaidi, Habib .
MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) :686-701
[5]   Novel adversarial semantic structure deep learning for MRI-guided attenuation correction in brain PET/MRI [J].
Arabi, Hossein ;
Zeng, Guodong ;
Zheng, Guoyan ;
Zaidi, Habib .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (13) :2746-2759
[6]   Comparative study of algorithms for synthetic CT generation from MRI: Consequences for MRI-guided radiation planning in the pelvic region [J].
Arabi, Hossein ;
Dowling, Jason A. ;
Burgos, Ninon ;
Han, Xiao ;
Greer, Peter B. ;
Koutsouvelis, Nikolaos ;
Zaidi, Habib .
MEDICAL PHYSICS, 2018, 45 (11) :5218-5233
[7]   Feasibility of CBCT-based proton dose calculation using a histogram-matching algorithm in proton beam therapy [J].
Arai, Kazuhiro ;
Kadoya, Noriyuki ;
Kato, Takahiro ;
Endo, Hiromitsu ;
Komori, Shinya ;
Abe, Yoshitomo ;
Nakamura, Tatsuya ;
Wada, Hitoshi ;
Kikuchi, Yasuhiro ;
Takai, Yoshihiro ;
Jingu, Keiichi .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 :68-76
[8]   Independent attenuation correction of whole body [18F]FDG-PET using a deep learning approach with Generative Adversarial Networks [J].
Armanious, Karim ;
Hepp, Tobias ;
Kuestnert, Thomas ;
Dittmann, Helmut ;
Nikolaou, Konstantin ;
La Fougere, Christian ;
Yang, Bin ;
Gatidis, Sergios .
EJNMMI RESEARCH, 2020, 10 (01)
[9]   Comparison of CBCT-based dose calculation methods in head and neck cancer radiotherapy: from Hounsfield unit to density calibration curve to deep learning [J].
Barateau, Anais ;
De Crevoisier, Renaud ;
Largent, Axel ;
Mylona, Eugenia ;
Perichon, Nicolas ;
Castelli, Joel ;
Chajon, Enrique ;
Acosta, Oscar ;
Simon, Antoine ;
Nunes, Jean-Claude ;
Lafond, Caroline .
MEDICAL PHYSICS, 2020, 47 (10) :4683-4693
[10]   IMAGE-GUIDED RADIOTHERAPY (IGRT) FOR PROSTATE CANCER COMPARING kV IMAGING OF FIDUCIAL MARKERS WITH CONE BEAM COMPUTED TOMOGRAPHY (CBCT) [J].
Barney, Brandon M. ;
Lee, R. Jeffrey ;
Handrahan, Diana ;
Welsh, Keith T. ;
Cook, J. Taylor ;
Sause, William T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01) :301-305