X-Ray Image Generation as a Method of Performance Prediction for Real-Time Inspection: a Case Study

被引:0
作者
Andriiashen, Vladyslav [1 ]
van Liere, Robert [1 ,2 ]
van Leeuwen, Tristan [1 ,3 ]
Batenburg, K. Joost [1 ,4 ]
机构
[1] Ctr Wiskunde Informat, Computat Imaging, Sci Pk 123, NL-1098 XG Amsterdam, Netherlands
[2] Tech Univ Eindhoven, Fac Wiskunde Informat, Groene Loper 5, NL-5612 AZ Eindhoven, Netherlands
[3] Univ Utrecht, Math Inst, Budapestlaan 6, NL-3584 CD Utrecht, Netherlands
[4] Leiden Univ, Leiden Inst Adv Comp Sci, Niels Bohrweg 1, NL-2333 CA Leiden, Netherlands
关键词
X-ray inspection; System Design; Dual-energy X-ray; Deep Convolutional neural networks; Probability of detection; NOISE; OPTIMIZATION; SIMULATION; CT;
D O I
10.1007/s10921-024-01091-8
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray imaging can be efficiently used for high-throughput in-line inspection of industrial products. However, designing a system that satisfies industrial requirements and achieves high accuracy is a challenging problem. The effect of many system settings is application-specific and difficult to predict in advance. Consequently, the system is often configured using empirical rules and visual observations. The performance of the resulting system is characterized by extensive experimental testing. We propose to use computational methods to substitute real measurements with generated images corresponding to the same experimental settings. With this approach, it is possible to observe the influence of experimental settings on a large amount of data and to make a prediction of the system performance faster than with conventional methods. We argue that a high accuracy of the image generator may be unnecessary for an accurate performance prediction. We propose a quantitative methodology to characterize the quality of the generation model using Probability of Detection curves. The proposed approach can be adapted to various applications and we demonstrate it on the poultry inspection problem. We show how a calibrated image generation model can be used to quantitatively evaluate the effect of the X-ray exposure time on the performance of the inspection system.
引用
收藏
页数:13
相关论文
共 37 条
[1]  
Ahmed I., 2022, VIRTUAL REAL INTELL, V4, P292, DOI [DOI 10.1016/J.VRIH.2022.03.002, 10.1016/j.vrih.2022.03.002]
[2]   Beam hardening: Analytical considerations of the effective attenuation coefficient of x-ray tomography [J].
Alles, J. ;
Mudde, R. F. .
MEDICAL PHYSICS, 2007, 34 (07) :2882-2889
[3]   CT-based data generation for foreign object detection on a single X-ray projection [J].
Andriiashen, Vladyslav ;
van Liere, Robert ;
van Leeuwen, Tristan ;
Batenburg, K. Joost .
SCIENTIFIC REPORTS, 2023, 13 (01)
[4]   Unsupervised Foreign Object Detection Based on Dual-Energy Absorptiometry in the Food Industry [J].
Andriiashen, Vladyslav ;
van Liere, Robert ;
van Leeuwen, Tristan ;
Batenburg, Kees Joost .
JOURNAL OF IMAGING, 2021, 7 (07)
[5]  
Baldo C.R., 2020, BRAZ TECHN S, P561, DOI [10.1007/978-3-030-75680-262, DOI 10.1007/978-3-030-75680-262]
[6]  
Bellon C., 2007, Proc DIR, P25
[7]  
Bircher B. A., 2021, JOINT SPEC INT GROUP
[8]   Explorative Imaging and Its Implementation at the FleX-ray Laboratory [J].
Coban, Sophia Bethany ;
Lucka, Felix ;
Palenstijn, Willem Jan ;
Van Loo, Denis ;
Batenburg, Kees Joost .
JOURNAL OF IMAGING, 2020, 6 (04)
[9]   X-ray computed tomography for quality inspection of agricultural products: A review [J].
Du, Zhe ;
Hu, Yongguang ;
Buttar, Noman Ali ;
Mahmood, Ashraf .
FOOD SCIENCE & NUTRITION, 2019, 7 (10) :3146-3160
[10]   Spectral and dual-energy X-ray imaging for medical applications [J].
Fredenberg, Erik .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 :74-87