Validation of the design of a high-sensitivity and high-resolution PET system for a preclinical PET/EPR hybrid scanner

被引:0
作者
Kim, Heejong [1 ]
Hua, Yuexuan [2 ]
Chen, Chin-Tu [1 ]
Epel, Boris [3 ]
Sundramoorthy, Subramanian [3 ]
Halpern, Howard [3 ]
Kao, Chien-Min [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Raycan Technol Co Ltd, Suzhou, Jiangsu, Peoples R China
[3] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
Positron emission tomography; Electron paramagnetic resonance oxygen; imaging; Hybrid imaging; Tumor hypoxia; TUMOR HYPOXIA; FLUOROMISONIDAZOLE;
D O I
10.1016/j.nima.2024.169333
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the development of a high-sensitivity and high-resolution PET subsystem for a next-generation preclinical PET/EPR hybrid scanner for investigating and improving hypoxia imaging with PET. The PET subsystem consists of 14 detector modules (DM) installed within a cylindrical supporting frame whose outer and inner diameters are 115 mm and 60 mm, respectively. Each DM contains eight detector units (DU) in a row and each DU is made of a 12 x 12 array of 1 x 1 x 10 mm3 3 LYSO crystals (with a 1.05 mm pitch) coupled to a 4 x 4 silicon photomultiplier (SiPM) array that has a 3.2 mm pitch (Hamamatsu multi-pixel photon counter (MPPC) array 14161-3050HS-04). The PET subsystem has a 104 mm axial field-of-view (AFOV) that is sufficient for full-body mouse imaging, therefore enabling temporal and spatial correlation studies of tumor hypoxia between PET and EPR. It employs 1 mm-width crystals to support sub-millimeter image resolution that is desired for mouse imaging. Although a DM contains 1,152 LYSO crystals, by use of a newly devised signal readout method only six outputs are produced. Recently a partial prototype of this subsystem consisting of four DMs is built. In this paper, we present performance measurement results obtained for the developed DMs and initial imaging results obtained by the prototype. The developed DMs show uniformly superior performance in identifying the hit crystal and detector unit, in energy resolution, and in coincidence time resolution. The images obtained for a 22 Na point source and a 18 F-filled U-shaped tube source show an image resolution of about 1.1 mm and 1.2 mm FWHM in the transverse and axial directions respectively, and demonstrate successful imaging over the entire 104 mm AFOV of the prototype. This estimated image resolution however includes the contribution by the source size.
引用
收藏
页数:7
相关论文
共 17 条
[1]   A Simple Capacitive Charge-Division Readout for Position-Sensitive Solid-State Photomultiplier Arrays [J].
Du, Junwei ;
Schmall, Jeffrey P. ;
Yang, Yongfeng ;
Di, Kun ;
Dokhale, Purushottam A. ;
Shah, Kanai S. ;
Cherry, Simon R. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) :3188-3197
[2]   Oxygen-Guided Radiation Therapy [J].
Epel, Boris ;
Maggio, Matthew C. ;
Barth, Eugene D. ;
Miller, Richard C. ;
Pelizzari, Charles A. ;
Krzykawska-Serda, Martyna ;
Sundramoorthy, Subramanian, V ;
Aydogan, Bulent ;
Weichselbaum, Ralph R. ;
Tormyshev, Victor M. ;
Halpern, Howard J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 103 (04) :977-984
[3]   The optimal 18F-fluoromisonidazole PET threshold to define tumor hypoxia in preclinical squamous cell carcinomas using pO2 electron paramagnetic resonance imaging as reference truth [J].
Gertsenshteyn, Inna ;
Epel, Boris ;
Ahluwalia, Amandeep ;
Kim, Heejong ;
Fan, Xiaobing ;
Barth, Eugene ;
Zamora, Marta ;
Markiewicz, Erica ;
Tsai, Hsiu-Ming ;
Sundramoorthy, Subramanian ;
Leoni, Lara ;
Lukens, John ;
Bhuiyan, Mohammed ;
Freifelder, Richard ;
Kucharski, Anna ;
Giurcanu, Mihai ;
Roman, Brian B. ;
Karczmar, Gregory ;
Kao, Chien-Min ;
Halpern, Howard ;
Chen, Chin-Tu .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (12) :4014-4024
[4]   Improving Tumor Hypoxia Location in 18F-Misonidazole PET with Dynamic Contrast-enhanced MRI Using Quantitative Electron Paramagnetic Resonance Partial Oxygen Pressure Images [J].
Gertsenshteyn, Inna ;
Epel, Boris ;
Barth, Eugene ;
Leoni, Lara ;
Markiewicz, Erica ;
Tsai, Hsiu-Ming ;
Fan, Xiaobing ;
Giurcanu, Mihai ;
Bodero, Darwin ;
Zamora, Marta ;
Sundramoorthy, Subramanian ;
Kim, Heejong ;
Freifelder, Richard ;
Bhuiyan, Mohammed ;
Kucharski, Anna ;
Karczmar, Gregory ;
Kao, Chien-Min ;
Halpern, Howard ;
Chen, Chin-Tu .
RADIOLOGY-IMAGING CANCER, 2021, 3 (02)
[5]   Design and Performance of a Resistor Multiplexing Readout Circuit for a SiPM Detector [J].
Goertzen, Andrew L. ;
Zhang, Xuezhu ;
McClarty, Megan M. ;
Berg, Eric J. ;
Liu, Chen-Yi ;
Kozlowski, Piotr ;
Retiere, Fabrice ;
Ryner, Lawrence ;
Sossi, Vesna ;
Stortz, Greg ;
Thompson, Christopher J. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) :1541-1549
[6]   Hypoxia imaging and radiotherapy: bridging the resolution gap [J].
Grimes, David Robert ;
Warren, Daniel R. ;
Warren, Samantha .
BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1076)
[7]   Tumor hypoxia:: Definitions and current clinical, biologic, and molecular aspects [J].
Höckel, M ;
Vaupel, P .
JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2001, 93 (04) :266-276
[8]  
Kim H, 2021, J INSTRUM, V16, DOI [10.1088/1748-0221/16/03/P03031, 10.1088/1748-0221/16/03/p03031]
[9]  
Kim H, 2023, IEEE T RADIAT PLASMA, V7, P794, DOI [10.1109/trpms.2023.3301788, 10.1109/TRPMS.2023.3301788]
[10]  
Kim H, 2021, IEEE T RADIAT PLASMA, V5, P662, DOI [10.1109/TRPMS.2021.3051364, 10.1109/trpms.2021.3051364]