Post-earthquake fire resistance of self-centering concrete beam-column joint: An experimental investigation

被引:5
|
作者
Wu, Zhenli [1 ]
Lu, Xilin [1 ]
Cai, Ziwei [1 ]
Li, Lingzhi [1 ]
Yu, Kequan [1 ]
Lu, Zhoudao [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
关键词
Fire resistance; Post-earthquake fire; Self-centering concrete joint; Posttensioned (PT) tendon; Bolted angle; END-PLATE CONNECTIONS; BEHAVIOR; PERFORMANCE; EARTHQUAKE; DAMAGE; TESTS;
D O I
10.1016/j.engstruct.2024.117689
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire is an accidental disaster resulting in disastrous consequences for building. Post -earthquake fire is a secondary disaster induced by earthquake, triggering off larger destruction in a higher probability of occurrence. The potential severity of consequences to structures makes fire and post -earthquake fire safety imperative in the design of any new structures. Self -centering concrete joints are introduced as a promoting alternative to traditional reinforced concrete (RC) joints. They always exhibit excellent seismic performance and self -centering capacity, available in high -seismic zone. However, the current lack of experimental data on fire response of self -centering concrete joints means that they remain an open issue in current design codes. In this paper, fullscale quasi -static cyclic test and fire tests were conducted on two self -centering concrete joints connected with bolted angles and posttensioned (PT) tendons. The experiments aimed to explore the performance of selfcentering joint in fire situations, and the impact of post -earthquake damages on fire response of self -centering joint. The deformation patterns and thermal responses of self -centering joints including temperature distribution, prestress force of PT tendons, displacements at beam ends and duration were recorded and analyzed. The results show that both self -centering joints exhibited satisfactory fire resistance with endurance over 170 min. Generally, the bolted angles and PT tendons in self -centering concrete joints showed acceptable working performance in fire. The findings unveil the actual response of self -centering concrete joints during the fire and postearthquake fire conditions, providing experimental data for further numerical simulation and analysis. It can be used to calibrate the design approach for self -centering joints under fire and seismic -induced fire exposure.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Cyclic loading tests of self-centering prestressed prefabricated steel beam-column joint with weakened FCP
    Jiang, Zi-Qin
    Chen, Mei-Lin
    Yang, Zhong-Shuai
    Li, Xiang-Yuan
    Cai, Chao
    ENGINEERING STRUCTURES, 2022, 252
  • [22] Seismic performance of full-scale self-centering reinforced concrete beam-column joints: Experimental, numerical and theoretical analysis
    Wu, Zhenli
    Lu, Xilin
    Li, Lingzhi
    Bao, Hongyin
    Lu, Zhoudao
    Yu, Kequan
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [23] Development of Novel Self-Centering Timber Beam-Column Connections with SMA Bars
    Huang, Jiahao
    Wang, Bin
    Chen, Zhi-Peng
    Zhu, Songye
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (08)
  • [24] Experimental investigation of a self-centering beam moment frame
    Department of Civil Engineering, Virginia Tech, Blacksburg
    VA, United States
    不详
    TX, United States
    Eng J, 2020, 4 (221-241): : 221 - 241
  • [25] Experimental Investigation of a Self-Centering Beam Moment Frame
    Eatherton, Matthew R.
    Maurya, Abhilasha
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2020, 57 (04): : 221 - 241
  • [26] Experimental and numerical study on the performance of a novel self-centering beam-column connection equipped with friction dampers
    Saeidzadeh, Mahsa
    Chenaghlou, Mohammad Reza
    Akbari Hamed, Arash
    Journal of Building Engineering, 2022, 52
  • [27] Post-earthquake fire resistance of beam-column connection connected with high-strength steel flush end-plate
    Xu, Jixiang
    Gan, Ziyang
    STRUCTURES, 2025, 71
  • [28] Experimental Study of a Novel Self-Centering Beam-Column Connection Equipped with Shape Memory Alloy Plates
    Yam, Michael C. H.
    Zhou, Xuhong
    Huang, Yun
    Ke, Ke
    STRUCTURES CONGRESS 2022, 2022, : 215 - 224
  • [29] Post-earthquake fire behavior of welded steel I-beam to hollow column connections: An experimental investigation
    Song, Qian-Yi
    Heidarpour, Amin
    Zhao, Xiao-Ling
    Han, Lin-Hai
    THIN-WALLED STRUCTURES, 2016, 98 : 143 - 153
  • [30] Seismic performance of SMA-prestressed self-centering beam-column joints: Experimental and numerical study
    Feng, Yutao
    Li, Weibin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226