Post-earthquake fire resistance of self-centering concrete beam-column joint: An experimental investigation

被引:5
|
作者
Wu, Zhenli [1 ]
Lu, Xilin [1 ]
Cai, Ziwei [1 ]
Li, Lingzhi [1 ]
Yu, Kequan [1 ]
Lu, Zhoudao [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
关键词
Fire resistance; Post-earthquake fire; Self-centering concrete joint; Posttensioned (PT) tendon; Bolted angle; END-PLATE CONNECTIONS; BEHAVIOR; PERFORMANCE; EARTHQUAKE; DAMAGE; TESTS;
D O I
10.1016/j.engstruct.2024.117689
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire is an accidental disaster resulting in disastrous consequences for building. Post -earthquake fire is a secondary disaster induced by earthquake, triggering off larger destruction in a higher probability of occurrence. The potential severity of consequences to structures makes fire and post -earthquake fire safety imperative in the design of any new structures. Self -centering concrete joints are introduced as a promoting alternative to traditional reinforced concrete (RC) joints. They always exhibit excellent seismic performance and self -centering capacity, available in high -seismic zone. However, the current lack of experimental data on fire response of self -centering concrete joints means that they remain an open issue in current design codes. In this paper, fullscale quasi -static cyclic test and fire tests were conducted on two self -centering concrete joints connected with bolted angles and posttensioned (PT) tendons. The experiments aimed to explore the performance of selfcentering joint in fire situations, and the impact of post -earthquake damages on fire response of self -centering joint. The deformation patterns and thermal responses of self -centering joints including temperature distribution, prestress force of PT tendons, displacements at beam ends and duration were recorded and analyzed. The results show that both self -centering joints exhibited satisfactory fire resistance with endurance over 170 min. Generally, the bolted angles and PT tendons in self -centering concrete joints showed acceptable working performance in fire. The findings unveil the actual response of self -centering concrete joints during the fire and postearthquake fire conditions, providing experimental data for further numerical simulation and analysis. It can be used to calibrate the design approach for self -centering joints under fire and seismic -induced fire exposure.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Investigation on a self-centering beam-column joint with tapered steel plate dampers
    Ru, Yangchao
    He, Liusheng
    Jiang, Huanjun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 197
  • [2] Post-earthquake repair and strengthening of reinforced concrete beam-column connections (theoretical & experimental investigation)
    Tsonos, Alexander G.
    Papanikolaou, Konstantinos V.
    Bulletin of the New Zealand Society for Earthquake Engineering, 2003, 36 (02): : 73 - 93
  • [3] Experimental Investigation of Friction-Damped Self-Centering Prestressed Concrete Beam-Column Connections with Hidden Corbels
    Huang, Linjie
    Zhou, Zhen
    Clayton, Patricia M.
    Zeng, Bin
    Qiu, Jian
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (03)
  • [4] Experimental Investigation on Self-Centering Steel-Timber Hybrid Beam-Column Connections
    Li, Zheng
    Chen, Fei
    He, Minjuan
    Long, Weiguo
    Ou, Jiajia
    Li, Minghao
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (03)
  • [5] Variable friction damped self-centering precast concrete beam-column connections with hidden corbels: Experimental investigation and theoretical analysis
    Huang, Linjie
    Zhou, Zhen
    Huang, Xiaogang
    Wang, Yongwei
    ENGINEERING STRUCTURES, 2020, 206
  • [6] Experimental study on behaviors of beam-column connections for self-centering post-tensioned precast frame
    Cai, Xiaoning
    Meng, Shaoping
    Sun, Weiwei
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2012, 45 (12): : 29 - 37
  • [7] Experimental investigation on seismic behavior of damaged self-centering friction beam-column joints after repair
    Lu, Xiao
    Sun, Weihao
    Xu, Longhe
    ENGINEERING STRUCTURES, 2024, 310
  • [8] Study of a self-centering beam-column joint with installed tapered steel plate links
    He, Liusheng
    Ru, Yangchao
    Bu, Haifeng
    Li, Ming
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 87 (04) : 391 - 403
  • [9] Experimental investigation on seismic performance of self-centering frictional cast-in-situ beam-column joints
    Lu, Xiao
    Xu, Hang
    Zhang, Xuemin
    Xie, Linlin
    ENGINEERING STRUCTURES, 2023, 285
  • [10] Study of a new type of self-centering beam-column joint in steel frame structures
    Jiang, Huanjun
    Bu, Haifeng
    He, Liusheng
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (14):