Inter-fractional error and intra-fractional motion of prostate and dosimetry comparisons of patient position registrations with versus without fiducial markers during treatment with carbon-ion radiotherapy

被引:0
作者
Iwai, Yuma [1 ]
Mori, Shinichiro [2 ]
Ishikawa, Hitoshi [1 ]
Kanematsu, Nobuyuki [2 ]
Matsumoto, Shinnosuke [2 ]
Nakaji, Taku [2 ]
Okonogi, Noriyuki [1 ]
Kobayashi, Kana [1 ]
Wakatsuki, Masaru [1 ]
Uno, Takashi [3 ]
Yamada, Shigeru [1 ]
机构
[1] QST Hosp, Natl Inst Quantum Sci & Technol, Chiba, Japan
[2] Natl Inst Quantum Sci & Technol, Inst Quantum Med Sci, Dept Accelerator & Med Phys, Chiba 2638555, Japan
[3] Chiba Univ Hosp, Dept Radiol, Chiba, Japan
关键词
Prostate cancer; Carbon-ion radiotherapy; Fiducial marker; Intra-fractional error; Inter-fractional error; Dosimetry; INTENSITY-MODULATED RADIOTHERAPY; RADIATION-THERAPY; NATIONAL INSTITUTE; TRACKING; ANATOMY; SYSTEM; CANCER;
D O I
10.1007/s12194-024-00808-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A few reports have discussed the influence of inter-fractional position error and intra-fractional motion on dose distribution, particularly regarding a spread-out Bragg peak. We investigated inter-fractional and intra-fractional prostate position error by monitoring fiducial marker positions. In 2020, data from 15 patients with prostate cancer who received carbon-ion beam radiotherapy (CIRT) with gold markers were investigated. We checked marker positions before and during irradiation to calculate the inter-fractional positioning and intra-fractional movement and evaluated the CIRT dose distribution by adjusting the planning beam isocenter and clinical target volume (CTV) position. We compared the CTV dose coverages (CTV receiving 95% [V95%] or 98% [V98%] of the prescribed dose) between skeletal and fiducial matching irradiation on the treatment planning system. For inter-fractional error, the mean distance between the marker position in the planning images and that in a patient starting irradiation with skeletal matching was 1.49 +/- 1.11 mm (95th percentile = 1.85 mm). The 95th percentile (maximum) values of the intra-fractional movement were 0.79 mm (2.31 mm), 1.17 mm (2.48 mm), 1.88 mm (4.01 mm), 1.23 mm (3.00 mm), and 2.09 mm (8.46 mm) along the lateral, inferior, superior, dorsal, and ventral axes, respectively. The mean V95% and V98% were 98.2% and 96.2% for the skeletal matching plan and 99.5% and 96.8% for the fiducial matching plan, respectively. Fiducial matching irradiation improved the CTV dose coverage compared with skeletal matching irradiation for CIRT for prostate cancer.
引用
收藏
页码:504 / 517
页数:14
相关论文
共 25 条
[1]   Intensity-modulated radiotherapy using implanted fiducial markers with daily portal imaging: Assessment of prostate organ motion [J].
Chen, Jergin ;
Lee, R. Jeffrey ;
Handrahan, Diana ;
Sause, William T. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :912-919
[2]   PROSTATE MOTION DURING STANDARD RADIOTHERAPY AS ASSESSED BY FIDUCIAL MARKERS [J].
CROOK, JM ;
RAYMOND, Y ;
SALHANI, D ;
YANG, H ;
ESCHE, B .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (01) :35-42
[3]   CONFORMAL ARC RADIOTHERAPY FOR PROSTATE CANCER: INCREASED BIOCHEMICAL FAILURE IN PATIENTS WITH DISTENDED RECTUM ON THE PLANNING COMPUTED TOMOGRAM DESPITE IMAGE GUIDANCE BY IMPLANTED MARKERS [J].
Engels, Benedikt ;
Soete, Guy ;
Verellen, D. ;
Storme, Guy .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02) :388-391
[4]   Estimation of late rectal normal tissue complication probability parameters in carbon ion therapy for prostate cancer [J].
Fukahori, Mai ;
Matsufuji, Naruhiro ;
Himukai, Takeshi ;
Kanematsu, Nobuyuki ;
Mizuno, Hideyuki ;
Fukumura, Akifumi ;
Tsuji, Hiroshi ;
Kamada, Tadashi .
RADIOTHERAPY AND ONCOLOGY, 2016, 118 (01) :136-140
[5]   Evaluation of internal margins for prostate for step and shoot intensity-modulated radiation therapy and volumetric modulated arc therapy using different margin formulas [J].
Higuchi, Daiki ;
Ono, Tomohiro ;
Kakino, Ryo ;
Aizawa, Rihito ;
Nakayasu, Naoki ;
Ito, Hitoshi ;
Sakamoto, Takashi .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (09)
[6]   Real-time Linear Fiducial Marker Tracking in Respiratory-gated Radiotherapy for Hepatocellular Carcinoma [J].
Hirai, R. ;
Watanabe, W. ;
Sakata, Y. ;
Tanizawa, A. ;
Mori, S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01) :E750-E751
[7]   Reformulation of a clinical-dose system for carbon-ion radiotherapy treatment planning at the National Institute of Radiological Sciences, Japan [J].
Inaniwa, Taku ;
Kanematsu, Nobuyuki ;
Matsufuji, Naruhiro ;
Kanai, Tatsuaki ;
Shirai, Toshiyuki ;
Noda, Koji ;
Tsuji, Hiroshi ;
Kamada, Tadashi ;
Tsujii, Hirohiko .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (08) :3271-3286
[8]  
International Electrotechnical Commission, 2002, Radiotherapy Equipment-Coordinates, Movements and Scales, P61217
[9]   Carbon ion radiation therapy for prostate cancer: Results of a prospective phase II study [J].
Ishikawa, Hitoshi ;
Tsuji, Hiroshi ;
Kamada, Tadashi ;
Yanagi, Takeshi ;
Mizoe, Jun-Etsu ;
Kanai, Tatsuaki ;
Morita, Shinroku ;
Wakatsuki, Masaru ;
Shimazaki, Jun ;
Tsujii, Hirohiko .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) :57-64
[10]   Carbon-ion radiation therapy for prostate cancer [J].
Ishikawa, Hitoshi ;
Tsuji, Hiroshi ;
Kamada, Tadashi ;
Akakura, Koichiro ;
Suzuki, Hiroyoshi ;
Shimazaki, Jun ;
Tsujii, Hirohiko .
INTERNATIONAL JOURNAL OF UROLOGY, 2012, 19 (04) :296-305