Performance of refrigerants employed in rooftop air-conditioners

被引:4
作者
Suerdem, Kaan [1 ]
Taner, Tolga [2 ]
Acikgoz, Ozgen [3 ]
Dalkilic, Ahmet Selim [3 ]
Panchal, Hitesh [4 ]
机构
[1] Alarko Carrier Ind & Trade Co Inc, Gebze Organized Ind Zone, TR-41480 Gebze, Turkiye
[2] Aksaray Univ, Dept Motor Vehicles & Transportat Technol, TR-68100 Aksaray, Turkiye
[3] Yildiz Tech Univ, Fac Mech Engn, Dept Mech Engn, TR-34349 Istanbul, Turkiye
[4] Govt Engn Coll Patan, Dept Mech Engn, Katpur, Gujarat, India
关键词
Refrigeration; EER; SEER; Life cycle climate performance; Rooftop air conditioner; LOW GWP; LCCP;
D O I
10.1016/j.jobe.2023.106301
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Unlike earlier studies, this study examines six refrigerants with various properties using the same rooftop air conditioning system of a building to evaluate performance. Performance metrics such as cooling capacity, energy consumption, temperature, and pressure were calculated. Laboratory testing of a rooftop air conditioner with R410a was performed to validate the simulation program's predicted data. Six distinct refrigerants' carbon emissions in two different scenarios were calculated using the Life Cycle Climate Performance technique, which was evaluated for environmental studies. These experimental tests were carried out at temperatures of 20 degrees C, 25 degrees C, 30 degrees C, and 35 degrees C, respectively. Maximum discrepancies between simulated and experimental results for cooling capacity, energy consumption, and energy efficiency were calculated to be 2.8%. The study found the lowest value in the R1234yf carbon emission at 51.30 kg CO(2)e. The highest cooling capacity was 154760.34 W in R454b, and the lowest cooling capacity was 76949.94 W in R1234yf. The highest EER value was 3,018 in R454b, while the lowest released was 2.257 in R22. The SEER value was 4.101 for R32 and 2.298 for R1234yf. The simulations concluded that R410a, R454b, and R32 refrigerants have superior cooling capacities.
引用
收藏
页数:19
相关论文
共 31 条
[21]  
Ozkan D., 2007, TTMD J., V52, P26
[22]   Performance enhancement and life cycle analysis of a novel solar HVAC system using underground water and energy recovery technique [J].
Rahman, S. M. A. ;
Issa, Salah ;
Assad, Mamdouh El Haj ;
Shah, Sheikh Khaleduzzaman ;
Abdelkareem, Mohammad Ali ;
Hoque, Md. Enamul ;
Olabi, A. G. .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2022, 36
[23]  
Reichler M., 1999, Modeling of Rooftop Packaged Air Conditioning Equipment
[24]  
Seyam S., 2018, HVAC Systems, P693
[25]   Theoretical Computation of Performance of Sustainable Energy Efficient R22 Alternatives for Residential Air Conditioners [J].
Shaik, Sharmas Vali ;
Babu, T. P. Ashok .
2017 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2017, 138 :710-716
[26]   Model-based optimizations of packaged rooftop air conditioners using low global warming potential refrigerants [J].
Shen, Bo ;
Abdelaziz, Omar ;
Shrestha, Som ;
Elatar, Ahmed .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 87 :106-117
[27]  
Soylu E., 2019, MSc thesis
[28]  
Suhermanto M., 2016, MSc thesis
[29]  
Troch S.V., 2016, HARMONIZATION LIFE C
[30]  