Using an LED Light Source Coupled With Spectral Image Analysis for Non-Invasive Glucose Detection

被引:1
作者
Ye, Zhi Ting [1 ]
Tseng, Shen Fu [1 ]
Tsou, Shang Xuan [1 ]
Ho, Wen Tsung [1 ]
机构
[1] Natl Chung Cheng Univ, Dept Mech Engn, Adv Inst Mfg High Tech Innovat, Chiayi 62102, Taiwan
来源
IEEE PHOTONICS JOURNAL | 2024年 / 16卷 / 03期
关键词
Glucose; ammonium metavanadate; sulfuric acid; color temperatures; white LED bulb; non-invasive; high sensitivity; quantitative analysis; SUBTYPES; SENSOR; STROKE; TYPE-1; RISK;
D O I
10.1109/JPHOT.2024.3393855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Glucose monitoring is critical for diabetes patients. However, invasive blood testing carries the risk of infection if wound care is not handled properly and non-invasive glucose testing devices are often bulky and not portable. Therefore, our study proposes the use of white light-emitting diode (LED) bulbs with different color temperatures as a light source. Additionally, ammonium metavanadate and sulfuric acid were used to prepare the detection solution instead of peroxidase to produce color, after which images were captured using a smartphone. The red, green, and blue (RGB) channels were then separated and converted into grayscale images. The average grayscale value changes in the images were analyzed to determine the linear relationship between glucose concentration and grayscale values, thus allowing for non-invasive quantitative glucose testing. When using a 3000K white LED bulb as the light source, the grayscale values of the RGB channels analyzed from the images exhibited a linear relationship with the glucose concentration at a 0.1-10 mM range. The regression equation for the red channel was y = -3.1184x+148.2, with a coefficient of determination (R-2) of 0.9165, a limit of detection (LOD) of 2.27 mM, and a limit of quantification (LOQ) of 6.88 mM. The proposed method of using white LED bulbs as a detection light source combined with image analysis can be used to determine whether glucose concentrations in blood, saliva, or tears are higher than normal, providing the advantages of rapid, highly sensitive, and non-invasive testing.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 56 条
[1]   A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration [J].
Abellan-Llobregat, A. ;
Jeerapan, Itthipon ;
Bandodkar, A. ;
Vidal, L. ;
Canals, A. ;
Wang, J. ;
Morallon, E. .
BIOSENSORS & BIOELECTRONICS, 2017, 91 :885-891
[2]   Defining and Classifying New Subgroups of Diabetes [J].
Balasubramanyam, Ashok .
ANNUAL REVIEW OF MEDICINE, VOL 72, 2021, 2021, 72 :63-74
[3]   Wearable Sensors for Biochemical Sweat Analysis [J].
Bandodkar, Amay J. ;
Jeang, William J. ;
Ghaffari, Roozbeh ;
Rogers, John A. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 12, 2019, 12 :1-22
[4]   A fluorescence digital image-based method using carbon quantum dots to evaluate the compliance of a biocidal agent [J].
Barbosa de Almeida, Joao Paulo ;
dos Santos, Vagner Bezerra ;
do Nascimento, Gustavo Alves ;
Suarez, Willian Toito ;
de Azevedo, Walter Mendes ;
Ferreira, Aldebara Fausto ;
Maia, Matheus Valentin .
ANALYTICAL METHODS, 2022, 14 (26) :2631-2641
[5]   Wearable sweat sensors [J].
Bariya, Mallika ;
Nyein, Hnin Yin Yin ;
Javey, Ali .
NATURE ELECTRONICS, 2018, 1 (03) :160-171
[6]   Glucose Sensing for Diabetes Monitoring: Recent Developments [J].
Bruen, Danielle ;
Delaney, Colm ;
Florea, Larisa ;
Diamond, Dermot .
SENSORS, 2017, 17 (08)
[7]   Type 2 diabetes [J].
Chatterjee, Sudesna ;
Khunti, Kamlesh ;
Davies, Melanie J. .
LANCET, 2017, 389 (10085) :2239-2251
[8]   Diabetes Mellitus and Risk of Stroke and Its Subtypes Among Japanese The Japan Public Health Center Study [J].
Cui, Renzhe ;
Iso, Hiroyasu ;
Yamagishi, Kazumasa ;
Saito, Isao ;
Kokubo, Yoshihiro ;
Inoue, Manami ;
Tsugane, Shoichiro .
STROKE, 2011, 42 (09) :2611-2614
[9]   An environment-friendly spot test method with digital imaging for the micro-titration of citric fruits [J].
de Oliveira, Larissa M. A. ;
dos Santos, Vagner Bezerra ;
da Silva, Emelle K. N. ;
Lopes, Alessandra Santos ;
Dantas-Filho, Heronides A. .
TALANTA, 2020, 206
[10]   Enzyme free glucose sensing by amino-functionalized silicon quantum dot [J].
Du, Liqing ;
Li, Zhongping ;
Yao, Jiaoli ;
Wen, Guangming ;
Dong, Chuan ;
Li, Hung-Wing .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 216 :303-309