Simultaneous quantification and confirmation of oxycodone and its metabolites in equine urine using ultra-high performance liquid chromatography-tandem mass spectrometry

被引:0
作者
You, Youwen [1 ,2 ]
Missanelli, Jaclyn R. [1 ,2 ]
Proctor, Rachel M. [1 ,2 ]
Haughan, Joanne [1 ]
Robinson, Mary A. [1 ,2 ]
机构
[1] Univ Penn, Dept Clin Studies, Sch Vet Med, New Bolton Ctr Campus,382 West St Rd, Kennett Sq, PA 19348 USA
[2] Penn Equine Toxicol & Res Lab, 220 East Rosedale Ave, W Chester, PA 19382 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2024年 / 1238卷
关键词
Oxycodone; Metabolites; Equine urine; LC-MS/MS; Quantification; Confirmation; CONTROLLED-RELEASE OXYCODONE; CAPILLARY-ELECTROPHORESIS; PHARMACOKINETICS; IDENTIFICATION; PHARMACODYNAMICS; EFFICACY; PATTERNS; SAFETY; CYP2D6; CYP3A;
D O I
10.1016/j.jchromb.2024.124125
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Oxycodone, an opioid commonly used to treat pain in humans, has the potential to be abused in racehorses to enhance their performance. To understand the pharmacokinetics of oxycodone and its metabolites in horses, as well as to detect the illegal use of oxycodone in racehorses, a method for quantification and confirmation of oxycodone and its metabolites is needed. In this study, we developed and validated an ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method that can simultaneously quantify and confirm oxycodone and eight metabolites in equine urine. Samples were subjected to enzymatic hydrolysis and then liquid-liquid extraction using ethyl acetate. The analyte separation was achieved on a Hypersil Gold C18 sub-2 mu m column and analytes were detected on a triple quadrupole mass spectrometer. The limit of detection (LOD) and lower limit of quantification (LLOQ) were 25-50 pg/mL and 100 pg/mL, respectively. Excellent linearity of the calibration curves was observed over a range of 100-10000 pg/mL for all nine analytes. Retention time, signal-to-noise ratio, and product ion ratios were utilized as confirmation criteria, with the limits of confirmation (LOC) ranging from 100 to 250 pg/mL. The data from a pilot pharmacokinetic (PK) study suggested that oxycodone metabolites have longer detection periods in equine urine compared to oxycodone itself; thus, the detection of metabolites in equine urine extends the ability to detect oxycodone exposure in racehorses.
引用
收藏
页数:10
相关论文
共 29 条
[1]  
[Anonymous], 2018, Bioanalytical method validation, guidance for industry.
[2]  
Association of Official Racing Chemists, 2016, AORC Guidelines for the Minimum Criteria for Identification by Chromatography and Mass Spectrometry
[3]  
Association of Official Racing Chemists, Uniform Classification Guidelines for Foreign Substances And Recommended Penalties Model Rule
[4]   Identification of new oxycodone metabolites in human urine by capillary electrophoresis-multiple-stage ion-trap mass spectrometry [J].
Baldacci, A ;
Caslavska, J ;
Wey, AB ;
Thormann, W .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1051 (1-2) :273-282
[5]   MU RECEPTOR-BINDING OF SOME COMMONLY USED OPIOIDS AND THEIR METABOLITES [J].
CHEN, ZR ;
IRVINE, RJ ;
SOMOGYI, AA ;
BOCHNER, F .
LIFE SCIENCES, 1991, 48 (22) :2165-2171
[6]   Prescription Opioids. I. Metabolism and Excretion Patterns of Oxycodone in Urine Following Controlled Single Dose Administration [J].
Cone, Edward J. ;
Heltsley, Rebecca ;
Black, David L. ;
Mitchell, John M. ;
LoDico, Charles P. ;
Flegel, Ronald R. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2013, 37 (05) :255-264
[7]   Observations of Urinary Oxycodone and Metabolite Distributions in Pain Patients [J].
Elder, Natalie M. ;
Atayee, Rabia S. ;
Best, Brookie M. ;
Ma, Joseph D. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2014, 38 (03) :129-134
[8]  
Federation Equestre Internationale, FEI Prohibited Substances Database
[9]   Selecting the Correct Weighting Factors for Linear and Quadratic Calibration Curves with Least-Squares Regression Algorithm in Bioanalytical LC-MS/MS Assays and Impacts of Using Incorrect Weighting Factors on Curve Stability, Data Quality, and Assay Performance [J].
Gu, Huidong ;
Liu, Guowen ;
Wang, Jian ;
Aubry, Anne-Francoise ;
Arnold, Mark E. .
ANALYTICAL CHEMISTRY, 2014, 86 (18) :8959-8966
[10]  
Hagen NA, 1997, CANCER-AM CANCER SOC, V79, P1428