A Blowdown Critical Heat Flux Experimental Vehicle

被引:0
作者
Moussaoui, Musa [1 ]
Marcum, Wade [1 ]
机构
[1] Oregon State Univ, Sch Nucl Sci & Engn, Corvallis, OR 97331 USA
关键词
Transient testing; critical heat flux; blowdown;
D O I
10.1080/00295450.2024.2309601
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the most challenging nuclear power plant accidents, transient critical heat flux (CHF) is a primary phenomenon that drives peak cladding temperature, and ultimately, fuel failure. It has not yet been determined whether the use of steady-state CHF methods can accurately predict transient CHF under the conditions of a blowdown due to a loss-of-coolant accident.There are limited comprehensive experiments at prototypic conditions. To address this deficiency, a quality separate-effects test facility was built to simulate an electrically heated rod under blowdown conditions. Testing reached full pressurized water reactor thermal-hydraulic conditions. With scaled break sizes as large as a double-end cold leg break, CHF was repeatedly measured with depressurization rates ranging from 7 to 17 MPa s-1.These measurements at prototypic conditions acquired in a controlled methodology are novel to the body of knowledge. Several steady-state CHF methods and heater models were evaluated using RELAP5-3D simulations and the Dakota framework. The results showed that many steady-state CHF methods performed inadequately, but that recently developed wide-ranged, look-up table methods had the most acceptable results. Additionally, the results showed no significant correlation between prediction accuracy and the depressurization rates tested.
引用
收藏
页码:2091 / 2114
页数:24
相关论文
共 37 条
[1]  
ADAMS B. M., 2020, SANDIA NATL LAB
[2]  
[Anonymous], 2018, HBR 2 UPDATED FSAR
[3]  
[Anonymous], 2021, FR
[4]  
[Anonymous], ACCOUNT OECD LOFT PR
[5]  
BIASI L, 1967, ENERG NUCL-MILAN, V14, P530
[6]  
BOWRING, 1972, AEEWR789 UKAEA
[7]  
Celata G. P., 1992, Waerme- und Stoffuebertragung, V27, P17, DOI 10.1007/BF01589974
[8]  
CELATA G. P., 1988, TRANSIENT CHF FLOW B
[9]  
CELATA G. P., 1987, P 4 MIAM INT S MULT
[10]   A DATA SET OF CRITICAL HEAT-FLUX OF BOILING R-12 IN UNIFORMLY HEATED VERTICAL TUBES UNDER TRANSIENT CONDITIONS [J].
CELATA, GP ;
CUMO, M ;
DANNIBALE, F .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1992, 5 (01) :78-107