Rotation insensitive implantable wireless power transfer system for medical devices using metamaterial-polarization converter

被引:3
作者
Shaw, Tarakeswar [1 ]
Mandal, Bappaditya [1 ]
Samanta, Gopinath [2 ]
Voigt, Thiemo [3 ]
Mitra, Debasis [4 ]
Augustine, Robin [1 ]
机构
[1] Uppsala Univ, Microwaves Med Engn Grp, Dept Elect Engn, Div Solid State Elect, S-75103 Uppsala, Sweden
[2] Lakshmi Niwas Mittal Inst Informat Technol, Dept Elect & Commun Engn, Jaipur 302031, Rajasthan, India
[3] Uppsala Univ, Dept Elect Engn, Div Networked Embedded Syst, S-75121 Uppsala, Sweden
[4] Indian Inst Engn Sci & Technol, Dept Elect & Telecommun Engn, Sibpur 711103, India
关键词
DIELECTRIC-PROPERTIES; METASURFACE; ANTENNA; FREQUENCY; RECTENNA; DESIGN;
D O I
10.1038/s41598-024-70591-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This article introduces an innovative approach for creating a circular polarization (CP) antenna-based rotation-insensitive implantable wireless power transfer (WPT) system for medical devices. The system is constructed to work in the industrial, scientific, and medical (ISM) frequency band of 902-928 MHz. Initially, a flexible, wide-band, and bio-compatible open-ended CP slot antenna is designed within a single-layer human skin tissue model to serve as the receiving (Rx) element. To form the implantable WPT link, a circular patch antenna is also constructed in the free-space to use as a transmitting (Tx) source. Further, a new metamaterial-polarization converter (MTM-PC) structure is developed and incorporated into the proposed system to enhance the power transfer efficiency (PTE). Furthermore, the rotational phenomenon of the Rx implant has been studied to show how the rotation affects the system's performance. Moreover, a numerical analysis of the specific absorption rate (SAR) is conducted to confirm compliance with safety regulations and prioritize human safety from electromagnetic exposure. Finally, to validate the introduced concept, prototypes of the different elements of the proposed WPT system were fabricated and tested using skin-mimicking gel and porcine tissue. The measured results confirm the feasibility of the introduced approach, exhibiting improved efficiency due to use of the MTM-PC. The amplitude of the transmission coefficient (|S21|\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$|S_{21}|$$\end{document}) has improved by 6.94 dB in the simulation, whereas the enhancement of 7.04 dB and 6.76 dB is obtained from the experimental study due to the integration of MTM-PC. As a result, the PTE of the proposed MTM-PC integrated implantable WPT system is increased significantly compared to the system without MTM-PC.
引用
收藏
页数:16
相关论文
共 45 条
[1]   Linear to left- and right-hand circular polarization conversion by using a metasurface structure [J].
Akgol, Oguzhan ;
Altintas, Olcay ;
Unal, Emin ;
Karaaslan, Muharrem ;
Karadag, Faruk .
INTERNATIONAL JOURNAL OF MICROWAVE AND WIRELESS TECHNOLOGIES, 2018, 10 (01) :133-138
[2]   Design of a wide band metasurface as a linear to circular polarization converter [J].
Altintas, Olcay ;
Unal, Emin ;
Akgol, Oguzhan ;
Karaaslan, Muharrem ;
Karadag, Faruk ;
Sabah, Cumali .
MODERN PHYSICS LETTERS B, 2017, 31 (30)
[3]  
[Anonymous], 2004, IEEE STD C951B 2004, P1, DOI [10.1109/IEEESTD.2004.95603, DOI 10.1109/IEEESTD.2004.95603]
[4]   A Dual-Band Implantable Rectenna for Wireless Data and Power Support at Sub-GHz Region [J].
Bakogianni, Sofia ;
Koulouridis, Stavros .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (11) :6800-6810
[5]   Sphere-Shaped Receiver Coil for Misalignment-Resilient Wireless Power Transfer Systems for Implantable Devices [J].
Basir, Abdul ;
Shah, Izaz Ali ;
Yoo, Hyoungsuk .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2022, 70 (09) :8368-8378
[6]   Far-Field RF Powering of Implantable Devices: Safety Considerations [J].
Bercich, Rebecca A. ;
Duffy, Daniel R. ;
Irazoqui, Pedro P. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (08) :2107-2112
[7]   Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review [J].
Das, Rupam ;
Moradi, Farshad ;
Heidari, Hadi .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (02) :343-358
[8]   A Radiating Near-Field Patch Rectenna for Wireless Power Transfer to Medical Implants at 2.4 GHz [J].
DeLong, Brock J. ;
Kiourti, Asimina ;
Volakis, John L. .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2018, 2 (01) :64-69
[9]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[10]   Wireless Power Transfer in the Radiative Near Field [J].
Gowda, Vinay R. ;
Yurduseven, Okan ;
Lipworth, Guy ;
Zupan, Tomislav ;
Reynolds, Matthew S. ;
Smith, David R. .
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2016, 15 :1865-1868