Development and evaluation of a candidate reference measurement procedure for detecting 17α-hydroxyprogesterone in dried blood spots using isotope dilution liquid chromatography tandem mass spectrometry

被引:0
|
作者
He, Ziyun [1 ,2 ]
Dai, Haibing [1 ,2 ]
Shen, Jian [3 ]
Huang, Yanjie [4 ]
Liu, Jinsong [1 ,2 ]
Yan, Renqing [1 ,2 ]
Zhang, Feng [1 ,2 ]
Yan, Shengkai [1 ,2 ]
机构
[1] Zunyi Med Univ, Dept Lab Med, Affiliated Hosp, Zunyi 563003, Peoples R China
[2] Zunyi Med Univ, Coll Lab Med, Zunyi 563000, Peoples R China
[3] Guangzhou Fenghua Biotech Co Ltd, Guangzhou 510730, Peoples R China
[4] South China Natl Ctr Metrol, Guangdong Prov Inst Metrol, Guangzhou 510405, Peoples R China
基金
中国国家自然科学基金;
关键词
Congenital adrenal hyperplasia; 17; alpha-Hydroxyprogesterone; Dried blood spots; Liquid chromatography tandem mass spectrometry; Newborn screening; STEROIDS;
D O I
10.1007/s00216-024-05411-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
17 alpha-Hydroxyprogesterone (17 alpha-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17 alpha-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17 alpha-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17 alpha-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17 alpha-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.
引用
收藏
页码:4635 / 4645
页数:11
相关论文
共 50 条
  • [1] Evaluation of a bracketing calibration-based isotope dilution liquid chromatography–tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma
    Qiaoxuan Zhang
    Lu Zhang
    Haibiao Lin
    Zhiliang Cai
    Jun Yan
    Qiqin Wang
    Liqiao Han
    Jianbing Wang
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7095 - 7104
  • [2] Evaluation of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma
    Zhang, Qiaoxuan
    Zhang, Lu
    Lin, Haibiao
    Cai, Zhiliang
    Yan, Jun
    Wang, Qiqin
    Han, Liqiao
    Wang, Jianbing
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (27) : 7095 - 7104
  • [3] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Susan S.-C. Tai
    Bei Xu
    Michael J. Welch
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1087 - 1094
  • [4] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    Phinney, Karen W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) : 1087 - 1094
  • [5] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [6] Measurement of serum 17-hydroxyprogesterone using isotope dilution liquid chromatography-tandem mass spectrometry candidate reference method and evaluation of the performance for three routine methods
    Long, Qichen
    Zhang, Tianjiao
    Yan, Ying
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Li, Shuijun
    Zhang, Jiangtao
    Zeng, Qingzhang
    Zhao, Beibei
    Zhang, Chuanbao
    Chen, Wenxiang
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (03) : 523 - 532
  • [7] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Zhang, Qiaoxuan
    Han, Liqiao
    Zheng, Songbai
    Ouyang, Fen
    Wu, Xiaobin
    Yan, Jun
    Zhan, Min
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4471 - 4481
  • [8] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Qiaoxuan Zhang
    Liqiao Han
    Songbai Zheng
    Fen Ouyang
    Xiaobin Wu
    Jun Yan
    Min Zhan
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4471 - 4481
  • [9] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Zhao, Haijian
    Zeng, Jie
    Zhang, Jiangtao
    Zhou, Weiyan
    Yan, Ying
    Wang, Yufei
    Wang, Mo
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (26) : 7403 - 7411
  • [10] Determination of serum glucose by isotope dilution liquid chromatography-tandem mass spectrometry: a candidate reference measurement procedure
    Tianjiao Zhang
    Chuanbao Zhang
    Haijian Zhao
    Jie Zeng
    Jiangtao Zhang
    Weiyan Zhou
    Ying Yan
    Yufei Wang
    Mo Wang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2016, 408 : 7403 - 7411