A prospective and consecutive study assessing short-term clinical and radiographic outcomes of Chinese domestically manufactured 3D printing trabecular titanium acetabular cup for primary total hip arthroplasty: evaluation of 236 cases

被引:2
作者
Chen, Guo [1 ]
Wang, Chen Yi [1 ]
Ma, Zou [1 ]
Yi, Hong Lin [1 ]
Bi, Na Meng [1 ]
Zhu, Wei Jiang [1 ]
Han, Jie [1 ]
Lu, Sha Li [1 ]
Zhang, Shang Shang [1 ]
Shen, Hai [1 ]
Zhang, Wu Hui [1 ]
Zhang, Peng [1 ]
Si, Yan [1 ]
机构
[1] Sichuan Prov Orthoped Hosp, Dept Geriatr Orthoped, Chengdu, Sichuan, Peoples R China
关键词
hip replacement; 3D printing technology; electron beam melting technology; porous titanium alloy; trabecular titanium acetabular cup; ARTHRITIS; DISLOCATION; ACCURACY; REDUCE; BONE;
D O I
10.3389/fsurg.2024.1279194
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: We prospectively evaluate the short-term clinical and radiographic outcomes of the only Chinese domestically produced trabecular titanium acetabular cup(3D ACT (TM) cup) in primary total hip arthroplasty (THA), aiming to provide evidence-based support for its clinical application. Methods: A total of 236 patients, who underwent primary THA using 3D ACT (TM) cup in the Department of Joint Surgery at our hospital between January 2017 and June 2019, were included in this study. General patient data, imaging information, functional scores, and complications were collected to evaluate the early clinical efficacy. Results: All patients were followed up for 33-52 months, with an average of (42.2 +/- 9.2) months. At the last follow-up, the preoperative HHS score increased significantly from 43.7 +/- 6.8 to 85.6 +/- 9.3 points (P < 0.01). Similarly, the preoperative WOMAC scores showed significant improvement from 59.2 +/- 5.8 to 13.1 +/- 3.5 points (P < 0.01). 92.3% of the patients expressed satisfaction or high satisfaction with the clinical outcome. Furthermore, 87.7% of the acetabular cups were positioned within the Lewinnek safe zone, achieving successful reconstruction of the acetabular rotation center. The cup survival rate at the last follow-up was 100%. Conclusions: The utilization of the only Chinese domestically manufactured 3D printing trabecular titanium acetabular cup in primary THA demonstrated favorable short-term clinical and radiographic outcomes. The acetabular cup exhibits excellent initial stability, high survival rate, and favorable osseointegration, leading to a significant enhancement in pain relief and functional improvement. In the future, larger sample sizes and multicenter prospective randomized controlled trials will be required to validate the long-term safety and effectiveness of this 3D ACT (TM) cup.
引用
收藏
页数:10
相关论文
共 43 条
[1]   What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position [J].
Abdel, Matthew P. ;
von Roth, Philipp ;
Jennings, Matthew T. ;
Hanssen, Arlen D. ;
Pagnano, Mark W. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (02) :386-391
[2]  
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[3]   Highly Porous Titanium Cups versus Hydroxyapatite-Coated Sockets: Midterm Results in Metachronous Bilateral Total Hip Arthroplasty [J].
Castagnini, Francesco ;
Bordini, Barbara ;
Yorifuji, Makiko ;
Giardina, Federico ;
Natali, Simone ;
Pardo, Francesco ;
Traina, Francesco .
MEDICAL PRINCIPLES AND PRACTICE, 2019, 28 (06) :559-565
[4]   Tranexamic acid attenuates early post-operative systemic inflammatory response and nutritional loss and avoids reduction of fibrinogen in total hip arthroplasty within an enhanced recovery after surgery pathway [J].
Chen Changjun ;
Zhao Xin ;
Luo Yue ;
Zhao Chengcheng ;
Wang Qiuru ;
Li Qianhao ;
Kang Pengde .
INTERNATIONAL ORTHOPAEDICS, 2021, 45 (11) :2811-2818
[5]   Total Hip Arthroplasty, state of the art for the 21st century [J].
Courpied, Jean-Pierre ;
Caton, Jacques Henri .
INTERNATIONAL ORTHOPAEDICS, 2011, 35 (02) :149-150
[6]   High prevalence and undertreatment of osteoporosis in elderly patients undergoing total hip arthroplasty [J].
Delsmann, M. M. ;
Strahl, A. ;
Muhlenfeld, M. ;
Jandl, N. M. ;
Beil, F. T. ;
Ries, C. ;
Rolvien, T. .
OSTEOPOROSIS INTERNATIONAL, 2021, 32 (08) :1661-1668
[7]  
Devine DP, 2012, METHODS MOL BIOL, V829, P65, DOI 10.1007/978-1-61779-458-2_4
[8]   The accuracy and reproducibility of radiographic assessment of stress-shielding - A postmortem analysis [J].
Engh, CA ;
McAuley, JP ;
Sychterz, CJ ;
Sacco, ME ;
Engh, CA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1414-1420
[9]   Cementless total hip arthroplasty in patients with severely dysplastic hips and a previous Schanz osteotomy of the femur Techniques, pitfalls, and long-term outcome [J].
Eskelinen, Antti ;
Remes, Ville ;
Ylinen, Pekka ;
Helenius, Ilkka ;
Tallroth, Kaj ;
Paavilainen, Timo .
ACTA ORTHOPAEDICA, 2009, 80 (03) :263-269
[10]   Three-dimensional-printed titanium implants for severe acetabular bone defects in revision hip arthroplasty: short- and mid-term results [J].
Fang, Sheng ;
Wang, Yiming ;
Xu, Peng ;
Zhu, Junke ;
Liu, Jinbo ;
Li, Huan ;
Sun, Xiaoliang .
INTERNATIONAL ORTHOPAEDICS, 2022, 46 (06) :1289-1297