Internal speckle pattern quality assessment and optimal selection of voxel points for digital volume correlation

被引:0
作者
Zou X. [1 ]
Zhang X. [1 ]
Wang Y. [2 ]
Pan B. [1 ]
机构
[1] Institute of Solid Mechanics, Beihang University, Beijing
[2] Institute of Chemical Materials, CAEP, Mianyang
来源
Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics | 2021年 / 53卷 / 07期
关键词
Digital volume correlation; Displacement; Image processing; Measurement; Speckle pattern;
D O I
10.6052/0459-1879-21-158
中图分类号
学科分类号
摘要
Digital volume correlation (DVC) is a powerful experimental tool for quantitative 3D internal deformation measurement throughout the interior of materials or biological tissues. By comparing the volumetric images acquired at the reference and deformed states by a volumetric imaging facility (e.g., X-ray CT), DVC provides full-field displacements with subvoxel accuracy and full-field strain maps. When using DVC method for internal deformation measurement, the quality of internal speckle pattern of a test sample has an important impact on the accuracy and precision of the measured displacements. In this work, theoretical analysis and numerical simulation experiments are firstly performed to assess the quality of internal speckle patterns. The results show that the displacement measurement error of DVC is negative correlation with the sum of square of subvolume intensity gradient (SSSIG) of a subvolume. Thus, the SSSIG value of a subvolume can be used as a simple and effective metric for quality assessment of its internal speckle pattern. In practical DVC analyses, increasing the SSSIG parameter of a subvolume helps to improve the measurement accuracy and precision of DVC. Despite the SSSIG in a subvolume can be increased by enlarging its subvolume size, this simple approach, however, would lead to increased calculation burden. With a purpose to increase SSSIG without significantly increase the amount of calculation, this paper further proposes a method for optimal selection of calculation voxel points in subvolumes. Specifically, the voxel points with small gray gradients in a subvolume are excluded from DVC calculation to decrease the amount of calculation when increasing the size of the subvolume. The efficacy of the presented voxel point optimal selection method is validated by analyzing computer simulated and experimentally obtained volume images. Experimental results reveal that the proposed voxel point selection method is capable of reducing the calculation burden when increasing the subvolume size to increase the SSSIG parameters. © 2021, Chinese Journal of Theoretical and Applied Mechanics Press. All right reserved.
引用
收藏
页码:1971 / 1980
页数:9
相关论文
共 31 条
  • [1] Pan B, Qian KM, Xie HM, Et al., Two-dimensional digital image correlation for in-plane displacement and strain measurement: A review, Measurement Science and Technology, 20, 6, (2009)
  • [2] Bay BK, Smith TS, Fyhrie DP, Et al., Digital volume correlation: Three-dimensional strain mapping using X-ray tomography, Experimental Mechanics, 39, 3, pp. 217-226, (1999)
  • [3] Benoit A, Guerard S, Gillet B, Et al., 3D analysis from micro-MRI during in situ compression on cancellous bone, Journal of Biomechanics, 42, 14, pp. 2381-2386, (2009)
  • [4] Wang B, Pan B., Incremental digital volume correlation method with nearest subvolume offset: An accurate and simple approach for large deformation measurement, Advances in Engineering Software, 116, pp. 80-88, (2018)
  • [5] Forsberg F, Sjodahl M, Mooser R, Et al., Full three-dimensional strain measurements on wood exposed to three-point bending: Analysis by use of digital volume correlation applied to synchrotron radiation micro-computed tomography image data, Strain, 46, 1, pp. 47-60, (2010)
  • [6] Yougun H, Dong-Woo K, Hyock-Ju K., Application of digital image cross-correlation and smoothing function to the diagnosis of breast cancer, Journal of the Mechanical Behavior of Biomedical Materials, 14, pp. 7-18, (2012)
  • [7] Bartosz P, Ludwig S, Tyler O, Et al., Water migration in one-side heated concrete: 4D in-situ CT monitoring of the moisture-clog-effect, Journal of Nondestructive Evaluation, 38, 1, pp. 15-20, (2019)
  • [8] Wang B, Sun LJ, Pan B., Mapping internal deformation fields in 3D printed porous structure with digital volume correlation, Polymer Testing, 78, (2019)
  • [9] Sukjamsri C, Geraldes DM, Gregory T, Et al., Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants, Journal of Biomechanics, 48, 12, pp. 3447-3454, (2015)
  • [10] Pan Bing, Wang Bo, Research progress in digital volume correlation method, Chinese Science Bulletin, 62, 16, pp. 1671-1681, (2017)