Effect of forced ventilation strategy on the thermal performance of finned-Trombe wall

被引:2
|
作者
Wu, Shuang-Ying [1 ,2 ]
Zheng, Hao [2 ]
Xiao, Lan [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400044, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 87卷
关键词
Finned-Trombe wall; Geometric structure parameters; Forced ventilation; Thermal performance; Convective heat transfer; NATURAL-CONVECTION; HEAT-TRANSFER; VENETIAN BLIND; RESIDENTIAL BUILDINGS; NUMERICAL-ANALYSIS; SHAPED CHANNELS; SOLAR WALLS; ENERGY; SYSTEMS; BEHAVIOR;
D O I
10.1016/j.jobe.2024.109021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Compared with the natural ventilation (NV) strategy, the forced ventilation (FV) strategy has inherent characteristics. However, the research on the effect of FV strategy on the thermal performance of finned-Trombe wall (F-TW) is still lacking so far. To fill this gap, in this study, a 3D numerical model that only takes into account heat loss through the glass cover was created to evaluate the impacts of ventilation strategy, inlet airflow speed, fin geometric factors and external environmental parameters on the thermal performance of F-TW. The main findings demonstrate that the thermal efficiency q th and exergic efficiency q ex under FV strategy first grow and then decline as the inlet airflow speed u in increases, with the extreme value appearing at around 0.50 m/s of u in . The optimal q th and q ex can reach 99.76% and 14.89% respectively when the relative fin height h * = 0.90 and relative fin spacing s * = 0.02. q th and q ex exhibit a tendency of steady growth with increasing h * and decreasing s *. The h * has a stronger impact on the thermal performance than s *. The FV strategy can not only improve the F-TW ' s thermal performance by effectively changing the flow and temperature fields in the channel, but also alters the variation law between s * and thermal performance. The optimal q th and q ex are both increased by 39.18%, compared with the NV strategy, and 13.49%, in comparison to the case without fins. Improving the solar radiation intensity, reducing the outdoor ambient wind speed and increasing the outdoor ambient temperature are beneficial to the F-TW ' s thermal performance. Aiming at F-TW, the significance of this study is to provide the basis for the performance assessment under the FV strategy, as well as the selection of different ventilation strategies.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Investigating the impact of Trombe wall parameters on thermal performance and room temperature in the Iraqi climate
    Ali, Mahmud H.
    Mawlood, Mahmood K.
    Jalal, Rawand E.
    HEAT TRANSFER, 2024, 53 (05) : 2600 - 2635
  • [32] Numerical study of the placement and thickness of blocks equipped with phase change materials in a Trombe wall in a room- thermal performance prediction using ANN
    Alqaed, Saeed
    Mustafa, Jawed
    Sharifpur, Mohsen
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2022, 141 : 91 - 116
  • [33] Effect of ventilation on the thermal performance of tunnel lining GHEs
    Zhang, Guozhu
    Xia, Caichu
    Zhao, Xu
    Zhou, Shuwei
    APPLIED THERMAL ENGINEERING, 2016, 93 : 416 - 424
  • [34] Effects of the position and melting point of the PCM layer on the comprehensive thermal performance of a Trombe wall under mixed dry climate
    Zhou, Shiqiang
    Song, Mengjie
    Shan, Kui
    Razaqpur, A. Ghani
    Huang, Jinhui Jeanne
    ENERGY AND BUILDINGS, 2024, 307
  • [35] Trombe wall's thermal and energy performance-A retrofitting approach for residential buildings in arid climate of Yazd, Iran
    Moosavi, Leila
    Alidoost, Sara
    Norouzi, Fatemeh
    Sattary, Sattar
    Banihashemi, Saeed
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2022, 14 (04)
  • [36] Thermal performance of a novel water blind-Trombe wall system: A comparative experimental investigation
    Hu, Zhongting
    Zhu, Maosheng
    Li, Kaijie
    Yang, Cuiqin
    Wang, Zijun
    He, Wei
    ENERGY CONVERSION AND MANAGEMENT, 2023, 296
  • [37] Evaluation of thermal performance and energy efficiency of a Trombe wall improved with dual phase change materials
    Askari, Minoo
    Jahangir, Mohammad Hossein
    ENERGY, 2023, 284
  • [38] Three-dimensional simulation on the thermal performance of a novel Trombe wall with venetian blind structure
    Hong, Xiaoqiang
    He, Wei
    Hu, Zhongting
    Wang, Chenchen
    Ji, Jie
    ENERGY AND BUILDINGS, 2015, 89 : 32 - 38
  • [39] The performance analysis of the photo-thermal driven synergetic catalytic PV-Trombe wall
    Yu, Bendong
    Fan, Miaomiao
    Gu, Tao
    Xia, Xiaokang
    Li, Niansi
    RENEWABLE ENERGY, 2022, 192 : 264 - 278
  • [40] Investigation on thermal performance of the wall-mounted attached ventilation for night cooling under hot summer conditions
    Ji, Wenhui
    Luo, Qing
    Zhang, Zili
    Wang, Houhua
    Du, Tao
    Heiselberg, Per Kvols
    BUILDING AND ENVIRONMENT, 2018, 146 : 268 - 279