Effect of forced ventilation strategy on the thermal performance of finned-Trombe wall

被引:2
|
作者
Wu, Shuang-Ying [1 ,2 ]
Zheng, Hao [2 ]
Xiao, Lan [1 ,2 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
[2] Chongqing Univ, Sch Energy & Power Engn, Chongqing 400044, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2024年 / 87卷
关键词
Finned-Trombe wall; Geometric structure parameters; Forced ventilation; Thermal performance; Convective heat transfer; NATURAL-CONVECTION; HEAT-TRANSFER; VENETIAN BLIND; RESIDENTIAL BUILDINGS; NUMERICAL-ANALYSIS; SHAPED CHANNELS; SOLAR WALLS; ENERGY; SYSTEMS; BEHAVIOR;
D O I
10.1016/j.jobe.2024.109021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Compared with the natural ventilation (NV) strategy, the forced ventilation (FV) strategy has inherent characteristics. However, the research on the effect of FV strategy on the thermal performance of finned-Trombe wall (F-TW) is still lacking so far. To fill this gap, in this study, a 3D numerical model that only takes into account heat loss through the glass cover was created to evaluate the impacts of ventilation strategy, inlet airflow speed, fin geometric factors and external environmental parameters on the thermal performance of F-TW. The main findings demonstrate that the thermal efficiency q th and exergic efficiency q ex under FV strategy first grow and then decline as the inlet airflow speed u in increases, with the extreme value appearing at around 0.50 m/s of u in . The optimal q th and q ex can reach 99.76% and 14.89% respectively when the relative fin height h * = 0.90 and relative fin spacing s * = 0.02. q th and q ex exhibit a tendency of steady growth with increasing h * and decreasing s *. The h * has a stronger impact on the thermal performance than s *. The FV strategy can not only improve the F-TW ' s thermal performance by effectively changing the flow and temperature fields in the channel, but also alters the variation law between s * and thermal performance. The optimal q th and q ex are both increased by 39.18%, compared with the NV strategy, and 13.49%, in comparison to the case without fins. Improving the solar radiation intensity, reducing the outdoor ambient wind speed and increasing the outdoor ambient temperature are beneficial to the F-TW ' s thermal performance. Aiming at F-TW, the significance of this study is to provide the basis for the performance assessment under the FV strategy, as well as the selection of different ventilation strategies.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Experimental investigation on the impact of fin structure factors on the finned-Trombe wall thermal performance
    Wu, Shuang-Ying
    Zheng, Hao
    Xiao, Lan
    Xiang, Yu
    JOURNAL OF BUILDING ENGINEERING, 2023, 70
  • [2] Experimental study of the influence of the vents on the thermal performance of a Trombe wall
    Laribi, Afef
    Begot, Sylvie
    Surdyk, Dominique
    Ait-Oumeziane, Yacine
    Lepiller, Valerie
    Desevaux, Philippe
    El Zein, Nour
    De Carvalho, Ana Ribeiro
    ENERGY AND BUILDINGS, 2025, 328
  • [3] Numerically predicting the effect of fin on solar Trombe wall performance
    Wu, Shuang-Ying
    Yan, Rong-Rong
    Xiao, Lan
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [4] Experimental study on thermal performance of an integrated PCM Trombe wall
    Duan, Shuangping
    Wang, Lin
    Zhao, Zhiqiang
    Zhang, Chengwang
    RENEWABLE ENERGY, 2021, 163 : 1932 - 1941
  • [5] Thermal performance of a passive test room with a Trombe wall in Tunisia
    Dimassi, N.
    Dehmani, L.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (02)
  • [6] Performance analysis of a purified Trombe wall with ventilation blinds based on photo-thermal driven purification
    Yu, Bendong
    Li, Niansi
    Ji, Jie
    APPLIED ENERGY, 2019, 255
  • [7] Effect of forced ventilation on the thermal performance of wet cooling towers
    Zhang, Deying
    Wang, Nini
    Li, Jinpeng
    Li, Jinheng
    He, Suoying
    Gao, Ming
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 35
  • [8] Thermal performance and ventilation analysis of a zigzag Trombe wall: Full numerical and experimental investigations
    Zhang, Hong-Liang
    Li, Bin
    Shi, Dun-Ke
    Zhao, Fu-Yun
    ENERGY AND BUILDINGS, 2024, 306
  • [9] Air purification and thermal performance of photocatalytic-Trombe wall based on multiple physical fields coupling
    Wu, Shuang-Ying
    Xu, Li
    Xiao, Lan
    RENEWABLE ENERGY, 2020, 148 : 338 - 348
  • [10] Effect of glazing type on the performance of a Trombe wall in Tunisia
    Mohamed, Lobna
    Dehmani, Leila
    Gagliano, Antonio
    2015 6TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2015,