Effectiveness of near-infrared light devices for peripheral intravenous cannulation in children and adolescents: A meta-analysis of randomized controlled trials

被引:5
作者
Li Annalyn, Si [1 ]
Leow, Xin Rong Gladys [1 ]
Ang, Wen Wei [1 ]
Lau, Ying [2 ,3 ]
机构
[1] Natl Univ Singapore, Alice Lee Ctr Nursing Studies, Yong Loo Lin Sch Med, Singapore, Singapore
[2] Chinese Univ Hong Kong, Nethersole Sch Nursing, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Shatin, 6-8-F Esther Lee Bldg, Hong Kong, Peoples R China
来源
JOURNAL OF PEDIATRIC NURSING-NURSING CARE OF CHILDREN & FAMILIES | 2024年 / 75卷
关键词
Pediatric patients; Peripheral intravenous cannulation; Near-infrared rays; Procedure time; Number of attempts; EMERGENCY-DEPARTMENT; CATHETER PLACEMENT; VEIN VIEWER; EFFICACY; VEINVIEWER; STANDARD; INFANTS; TRANSILLUMINATION; INTERVENTIONS; ACCUVEIN;
D O I
10.1016/j.pedn.2023.12.034
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objectives: To examine the effectiveness of near -infrared light devices (NIR) on procedure time of successful cannulation, success rate at the first attempt, and pain scores among pediatric patients and explore potential covariates on the intervention effect. Background: Pediatric patients have encountered a high failure rate as compared with adult patients using traditional cannulation. NIR devices might help to access veins with an optimum viewing area and eliminate the number of attempts. However, methodological limitations and inconsistent results from previous reviews were found. Methods: A three -step comprehensive search was performed in nine databases. Meta -analysis, subgroup, and meta -regression analyses were conducted. Individual quality assessment and certainty of evidence were assessed using the Cochrane risk of bias tool and the Grading of Recommendations, Assessments, Development, and Evaluation criteria, respectively. Results: We included 18 randomized controlled trials (RCTs) with 5298 children and adolescents across nine countries. NIR light devices significantly reduce -29.43 s of procedure time and -0.47 attempts of peripheral intravenous cannulation compared with traditional methods. Subgroup analysis observed a significantly large effect size on procedure time using AccuVein with pre -procedure training at the clinics. However, NIR light devices do not significantly decrease the procedure time, first attempt success rate, and pain scores. Meta -regression identified sample size as a significant covariate that had an impact on the success rate at the first attempt. Conclusions: The near -infrared light device can statistically significantly reduce the procedure time and the number of attempts. Given the low or very low certainty of the evidence, future well -designed RCTs are necessary. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:e81 / e92
页数:12
相关论文
共 66 条
[1]  
Akdovan T., 1999, master's thesis
[2]  
Alexandrou Evan, 2018, J Hosp Med, V13, DOI 10.12788/jhm.3039
[3]   Defining risk factors associated with difficult peripheral venous Cannulation: A systematic review and meta-analysis [J].
Angel Rodriguez-Calero, Miguel ;
Blanco-Mavillard, Ian ;
Miguel Morales-Asencio, Jose ;
Fernandez-Fernandez, Ismael ;
Castro-Sanchez, Enrique ;
Ernest De Pedro-Gomez, Joan .
HEART & LUNG, 2020, 49 (03) :273-286
[4]   Efficacy of AccuVein to Facilitate Peripheral Intravenous Placement in Adults Presenting to an Emergency Department: A Randomized Clinical Trial [J].
Aulagnier, Jerome ;
Hoc, Cecile ;
Mathieu, Emmanuel ;
Dreyfus, Jean Francois ;
Fischler, Marc ;
Le Guen, Morgan .
ACADEMIC EMERGENCY MEDICINE, 2014, 21 (08) :858-863
[5]   Validation of the COMFORT Behavior Scale and the FLACC Scale for Pain Assessment in Chinese Children after Cardiac Surgery [J].
Bai, Jinbing ;
Hsu, Lily ;
Tang, Yan ;
van Dijk, Monique .
PAIN MANAGEMENT NURSING, 2012, 13 (01) :18-26
[6]  
Bitencourt E. S., 2018, Cogitare Enferm, V23, DOI DOI 10.5380/CE.V23I1.49361
[7]   A basic introduction to fixed-effect and random-effects models for meta-analysis [J].
Borenstein, Michael ;
Hedges, Larry V. ;
Higgins, Julian P. T. ;
Rothstein, Hannah R. .
RESEARCH SYNTHESIS METHODS, 2010, 1 (02) :97-111
[8]   Effect Size Guidelines, Sample Size Calculations, and Statistical Power in Gerontology [J].
Brydges, Christopher R. .
INNOVATION IN AGING, 2019, 3 (04)
[9]   Efficacy of Vein Visualization Devices for Peripheral Intravenous Catheter Placement in Preterm Infants A Randomized Clinical Trial [J].
Caglar, Seda ;
Buyukyilmaz, Funda ;
Bakoglu, Ilkay ;
Inal, Sevil ;
Salihoglu, Ozgul .
JOURNAL OF PERINATAL & NEONATAL NURSING, 2019, 33 (01) :61-67
[10]   Factors associated with peripheral intravenous cannulation first-time insertion success in the emergency department. A multicentre prospective cohort analysis of patient, clinician and product characteristics [J].
Carr, Peter J. ;
Rippey, James C. R. ;
Cooke, Marie L. ;
Trevenen, Michelle L. ;
Higgins, Niall S. ;
Foale, Aileen S. ;
Rickard, Claire M. .
BMJ OPEN, 2019, 9 (04)