Biocompatible Gold Nanoparticles-Modified Fluorine Doped Tin Oxide Electrode for the Fabrication of Enzyme-Free Glucose Sensor

被引:0
作者
Abu Nayem, S. M. [1 ]
Islam, Santa [1 ]
Shah, Syed Shaheen [2 ]
Awal, Abdul [1 ]
Ghann, William [3 ]
Anand, Deepak [4 ]
Ahmad, Irshad [4 ,5 ]
Uddin, Jamal [3 ]
Aziz, Md. Abdul [6 ]
Ahammad, A. J. Saleh [1 ]
机构
[1] Jagannath Univ, Dept Chem, Dhaka 1100, Bangladesh
[2] Kyoto Univ, Grad Sch Engn, Dept Mat Chem, Nishikyo Ku, Kyoto 6158520, Japan
[3] Coppin State Univ, Ctr Nanotechnol, Dept Nat Sci, 2500 W North Ave, Baltimore, MD USA
[4] King Fahd Univ Petr & Minerals KFUPM, Dept Bioengn, Dhahran 31261, Saudi Arabia
[5] King Fahd Univ Petr & Minerals KFUPM, Interdisciplinary Res Ctr Membranes & Water Secur, Dhahran 31261, Saudi Arabia
[6] King Fahd Univ Petr & Minerals, Interdisciplinary Res Ctr Hydrogen Technol & Carbo, KFUPM Box 5040, Dhahran 31261, Saudi Arabia
关键词
Jute extract; AuNPs; Biocompatible; Glucose detection; Electrochemical Sensor; GREEN SYNTHESIS; CARBON; FILM; ELECTROCATALYSIS; GRAPHENE; BIOSENSOR; POINT;
D O I
10.1002/asia.202400074
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work demonstrates the use of jute stick extract as a reducing and stabilizing agent for the synthesis of spherical gold nanoparticles (AuNPs). In UV-Vis spectroscopy, peak at 550 nm was used to confirm the formation of AuNPs. The spherical surface morphology of AuNPs was determined through SEM and TEM analysis. While XRD investigation revealed the crystallinity of the prepared AuNPs. To ensure the biocompatibility of synthesized AuNPs, a bacterial investigation was conducted with negative results towards bacterial strain. The, modified FTO with AuNPs were able to detect glucose in CV analysis and the constructed sensor displayed a wide linear range of 50 mu M to 40 mM with a detection limit of 20 mu M. Scan rate analysis was performed to determine the charge transfer coefficient (0.42) and Tafel slope (102 mV/decade). Furthermore, the interfacial surface mechanism is illustrated to understand the interaction of glucose with the electrode surface in an alkaline medium and the product formation through the dehydrogenation and hydrolysis process. The prepared sensor also showed good stability, reproducibility, and anti-interference capabilities. In the case of real sample analysis, we used a blood serum sample. A low RSD value (<10 %) suggests the practical use of AuNPs/FTO in real-life applications.
引用
收藏
页数:16
相关论文
共 50 条
[11]   Enzyme-Free Glucose Sensor Based on Micro-nano Dualporous Gold-Modified Screen-Printed Carbon Electrode [J].
Nguyen Xuan Viet ;
Chikae, Miyuki ;
Ukita, Yoshiaki ;
Takamura, Yuzuru .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09) :8633-8644
[12]   Enzyme-free glucose sensor using a glassy carbon electrode modified with reduced graphene oxide decorated with mixed copper and cobalt oxides [J].
Li, Su-Juan ;
Hou, Lin-Lin ;
Yuan, Bai-Qing ;
Chang, Meng-Zhu ;
Ma, Yu ;
Du, Ji-Min .
MICROCHIMICA ACTA, 2016, 183 (06) :1813-1821
[13]   Fabrication and enzyme-free electrochemical sensing response of polyaniline/silver/clove modified composite electrode [J].
Alamry, Khalid A. ;
Khan, Ajahar ;
Hussein, Mahmoud A. .
SYNTHETIC METALS, 2022, 285
[14]   An original ferroferric oxide and gold nanoparticles-modified glassy carbon electrode for the determination of bisphenol A [J].
Santana, Edson R. ;
de Lima, Camila A. ;
Piovesan, Jamille V. ;
Spinelli, Almir .
SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 :487-496
[15]   A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode [J].
Zhang, JD ;
Oyama, M .
ELECTROCHIMICA ACTA, 2004, 50 (01) :85-90
[16]   Amperometric Enzyme-Free Glucose Sensor Based on Electrodeposition of Au Particles on Polyaniline Film Modified Pt Electrode [J].
Malhotra, Shveta ;
Tang, Yijun ;
Varshney, Pradeep K. .
ACTA CHIMICA SLOVENICA, 2018, 65 (03) :687-697
[17]   A novel enzyme-free FI-amperometric glucose biosensor at Cu nanoparticles modified graphite pencil electrode [J].
Ayaz, Selen ;
Karakaya, Serkan ;
Emir, Gamze ;
Dilgin, Didem Giray ;
Dilgin, Yusuf .
MICROCHEMICAL JOURNAL, 2020, 154
[18]   Physical and Electrochemical Properties of Iron Oxide Nanoparticles-modified Electrode for Amperometric Glucose Detection [J].
Nor, Noorhashimah Mohamad ;
Razak, Khairunisak Abdul ;
Lockman, Zainovia .
ELECTROCHIMICA ACTA, 2017, 248 :160-168
[19]   Fabrication and Characterization of Electrochemical Organophosphate Sensor Device Based on Doped Tin Oxide Nanoparticles [J].
Khatoon, Zeenat ;
Hassanein, Azza S. ;
Fouad, H. ;
Ansari, Z. A. ;
Alothman, Othman Y. ;
Alnbaheen, May S. ;
Ansari, S. G. .
JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2018, 13 (07) :1082-1089
[20]   Nonenzymatic glucose sensor based on ITO electrode modified with gold nanoparticles by ion implantation [J].
Fu, Yingyi ;
Liang, Fenfen ;
Tian, Huifeng ;
Hu, Jingbo .
ELECTROCHIMICA ACTA, 2014, 120 :314-318