Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

被引:0
|
作者
Wiggins, Cody S. [1 ,2 ]
Cabral, Arturo [2 ]
Mafi, Adam [2 ]
Houston, Jerel [2 ]
Carasik, Lane B. [2 ]
机构
[1] Oak Ridge Natl Lab, Fus Energy Div, Oak Ridge, TN USA
[2] Virginia Commonwealth Univ, Dept Mech & Nucl Engn, Richmond, VA 23284 USA
关键词
PRESSURE-DROP CORRELATIONS; HEAT-TRANSFER; ISOTHERMAL TUBES; TURBULENT-FLOW; INSERTS; PERFORMANCE;
D O I
10.1007/s00348-024-03860-7
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300-63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements
    Wiggins, Cody S.
    Cabral, Arturo
    Carasik, Lane B.
    NUCLEAR ENGINEERING AND DESIGN, 2023, 403
  • [2] Noninvasive interrogation of local flow phenomena in twisted tape swirled flow via positron emission particle tracking (PEPT)
    Wiggins, Cody S.
    Carasik, Lane B.
    Ruggles, Arthur E.
    NUCLEAR ENGINEERING AND DESIGN, 2022, 387
  • [3] POSITRON EMISSION PARTICLE TRACKING (PEPT) VALIDATION FOR JET FLOW
    Langford, Seth
    Wiggins, Cody
    Patel, Nitant
    Ruggles, Arthur
    PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 5, 2016,
  • [4] Positron Emission Particle Tracking (PEPT) for Fluid Flow Measurements
    Langford, Seth
    Wiggins, Cody
    Tenpenny, Daniel
    Ruggles, Arthur
    NUCLEAR ENGINEERING AND DESIGN, 2016, 302 : 81 - 89
  • [5] Flow studies in stirred tanks by positron emission particle tracking (PEPT)
    Fangary, YS
    Seville, JPK
    Barigou, M
    FLUID MIXING 6, 1999, (146): : 23 - 34
  • [6] An X-ray Computed Tomography/Positron Emission Tomography System Designed Specifically for Breast Imaging
    Boone, John M.
    Yang, Kai
    Burkett, George W.
    Packard, Nathan J.
    Huang, Shih-ying
    Bowen, Spencer
    Badawi, Ramsey D.
    Lindfors, Karen K.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (01) : 29 - 43
  • [7] Positron emission and computed X-ray tomography: a coming together
    Costa, DC
    Visvikis, D
    Crosdale, I
    Pigden, I
    Townsend, C
    Bomanji, J
    Prvulovich, E
    Lonn, A
    Ell, PJ
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (04) : 351 - 358
  • [8] Positron emission tomography and X-ray computed tomography: tools for mouse phenotyping?
    SR Cherry
    Breast Cancer Research, 5 (Suppl 1)
  • [9] Influence of X-ray computed tomography (CT) exposure and reconstruction parameters on positron emission tomography (PET) quantitation
    Shon, Ivan Ho
    Reece, Christopher
    Hennessy, Thomas
    Horsfield, Megan
    McBride, Bruce
    EJNMMI PHYSICS, 2020, 7 (01)
  • [10] Influence of X-ray computed tomography (CT) exposure and reconstruction parameters on positron emission tomography (PET) quantitation
    Ivan Ho Shon
    Christopher Reece
    Thomas Hennessy
    Megan Horsfield
    Bruce McBride
    EJNMMI Physics, 7