Comparison of synthesized and acquired high b-value diffusion-weighted MRI for detection of prostate cancer

被引:1
作者
Kallis, Karoline [2 ]
Conlin, Christopher C. [1 ]
Zhong, Allison Y. [2 ]
Hussain, Troy S. [2 ]
Chatterjee, Aritrick [6 ,7 ]
Karczmar, Gregory S. [6 ,7 ]
Rakow-Penner, Rebecca [1 ]
Dale, Anders M. [1 ,3 ,4 ]
Seibert, Tyler M. [1 ,2 ,5 ]
机构
[1] Univ Calif San Diego Hlth, Dept Radiol, San Diego, CA 92093 USA
[2] Univ Calif San Diego Hlth, Dept Radiat Med & Appl Sci, La Jolla, CA 92093 USA
[3] Univ Calif San Diego Hlth, Dept Neurosci, San Diego, CA USA
[4] Univ Calif San Diego, Halicioglu Data Sci Inst, San Diego, CA USA
[5] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, San Diego, CA 92093 USA
[6] Univ Chicago, Dept Radiol, Chicago, IL USA
[7] Univ Chicago, Sanford J Grossmann Ctr Excellence Prostate Imagin, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
Diffusion-weighted imaging; Prostate cancer; Synthetic high b-values; Restricted Spectrum Imaging; FEASIBILITY; DIAGNOSIS; PERFUSION; IMAGES; TISSUE; DWI;
D O I
10.1186/s40644-024-00723-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background High b-value diffusion-weighted images (DWI) are used for detection of clinically significant prostate cancer (csPCa). This study qualitatively and quantitatively compares synthesized DWI (sDWI) to acquired (aDWI) for detection of csPCa. Methods One hundred fifty-one consecutive patients who underwent prostate MRI and biopsy were included in the study. Axial DWI with b = 0, 500, 1000, and 2000 s/mm(2) using a 3T clinical scanner using a 32-channel phased-array body coil were acquired. We retrospectively synthesized DWI for b = 2000 s/mm(2) via extrapolation based on mono-exponential decay, using b = 0 and b = 500 s/mm(2) (sDWI(500)) and b = 0, b = 500 s/mm(2), and b = 1000 s/mm(2) (sDWI(1000)). Differences in signal intensity between sDWI and aDWI were evaluated within different regions of interest (prostate alone, prostate plus 5 mm, 30 mm and 70 mm margin and full field of view). The maximum DWI value within each ROI was evaluated for prediction of csPCa. Classification accuracy was compared to Restriction Spectrum Imaging restriction score (RSIrs), a previously validated biomarker based on multi-exponential DWI. Discrimination of csPCa was evaluated via area under the receiver operating characteristic curve (AUC). Results Within the prostate, mean +/- standard deviation of percent mean differences between sDWI and aDWI signal were -46 +/- 35% for sDWI(1000) and -67 +/- 24% for sDWI(500). AUC for aDWI, sDWI(500,) sDWI(1000), and RSIrs within the prostate 0.62[95% confidence interval: 0.53, 0.71], 0.63[0.54, 0.72], 0.65[0.56, 0.73] and 0.78[0.71, 0.86], respectively. Conclusions DWI is qualitatively comparable to aDWI within the prostate. However, hyperintense artifacts are introduced with sDWI in the surrounding pelvic tissue that interfere with quantitative cancer detection and might mask metastases. In the prostate, RSIrs yields superior quantitative csPCa detection than sDWI or aDWI.
引用
收藏
页数:11
相关论文
共 50 条
[31]   Ultra-high-b-value diffusion-weighted MR imaging for the detection of prostate cancer: evaluation in 201 cases with histopathological correlation [J].
Katahira, Kazuhiro ;
Takahara, Taro ;
Kwee, Thomas C. ;
Oda, Seitaro ;
Suzuki, Yasuko ;
Morishita, Shoji ;
Kitani, Kosuke ;
Hamada, Yasuyuki ;
Kitaoka, Mitsuhiko ;
Yamashita, Yasuyuki .
EUROPEAN RADIOLOGY, 2011, 21 (01) :188-196
[32]   The expanding landscape of diffusion-weighted MRI in prostate cancer [J].
Andreas G. Wibmer ;
Evis Sala ;
Hedvig Hricak ;
Hebert Alberto Vargas .
Abdominal Radiology, 2016, 41 :854-861
[33]   The expanding landscape of diffusion-weighted MRI in prostate cancer [J].
Wibmer, Andreas G. ;
Sala, Evis ;
Hricak, Hedvig ;
Vargas, Hebert Alberto .
ABDOMINAL RADIOLOGY, 2016, 41 (05) :854-861
[34]   Prostate cancer detection with 3-T MRI: Comparison of diffusion-weighted and T2-weighted imaging [J].
Miao, Huadong ;
Fukatsu, Hiroshi ;
Ishigaki, Takeo .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 61 (02) :297-302
[35]   Pancreatic neuroendocrine tumor: Added value of fusion of T2-weighted imaging and high b-value diffusion-weighted imaging for tumor detection [J].
Brenner, Renata ;
Metens, Thierry ;
Bali, Maria ;
Demetter, Pieter ;
Matos, Celso .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (05) :E746-E749
[36]   Triexponential function analysis of diffusion-weighted MRI for diagnosing prostate cancer [J].
Ueda, Yu ;
Takahashi, Satoru ;
Ohno, Naoki ;
Kyotani, Katsusuke ;
Kawamitu, Hideaki ;
Miyati, Tosiaki ;
Aoyama, Nobukazu ;
Ueno, Yoshiko ;
Kitajima, Kazuhiro ;
Kawakami, Fumi ;
Okuaki, Tomoyuki ;
Tsukamoto, Ryuko ;
Yanagita, Emmy ;
Sugimura, Kazuro .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) :138-148
[37]   Optimization of b-value sampling for diffusion-weighted imaging of the kidney [J].
Zhang, Jeff L. ;
Sigmund, Eric E. ;
Rusinek, Henry ;
Chandarana, Hersh ;
Storey, Pippa ;
Chen, Qun ;
Lee, Vivian S. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (01) :89-97
[38]   Diagnostic accuracy of high b-value diffusion weighted imaging for patients with prostate cancer: a diagnostic comprehensive analysis [J].
Li, Chao ;
Li, Na ;
Li, Zhanzhan ;
Shen, Liangfang .
AGING-US, 2021, 13 (12) :16404-16424
[39]   Potential diagnostic value of high b-value computed diffusion-weighted imaging in hepatocellular carcinoma [J].
Ablefoni, Maxime ;
Richter, Theresa ;
Leonhardi, Jakob ;
Ehrengut, Constantin ;
Prasse, Gordian ;
Mehdorn, Matthias ;
Seehofer, Daniel ;
Hoehn, Anne Kathrin ;
Denecke, Timm ;
Meyer, Hans-Jonas .
CLINICAL AND EXPERIMENTAL HEPATOLOGY, 2024, 10 (02) :129-136
[40]   Feasibility Study of Synthetic Diffusion-Weighted MRI in Patients with Breast Cancer in Comparison with Conventional Diffusion-Weighted MRI [J].
Choi, Bo Hwa ;
Baek, Hye Jin ;
Ha, Ji Young ;
Ryu, Kyeong Hwa ;
Moon, Jin Il ;
Park, Sung Eun ;
Bae, Kyungsoo ;
Jeon, Kyung Nyeo ;
Jung, Eun Jung .
KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (09) :1036-1044