Comparison of synthesized and acquired high b-value diffusion-weighted MRI for detection of prostate cancer

被引:0
作者
Kallis, Karoline [2 ]
Conlin, Christopher C. [1 ]
Zhong, Allison Y. [2 ]
Hussain, Troy S. [2 ]
Chatterjee, Aritrick [6 ,7 ]
Karczmar, Gregory S. [6 ,7 ]
Rakow-Penner, Rebecca [1 ]
Dale, Anders M. [1 ,3 ,4 ]
Seibert, Tyler M. [1 ,2 ,5 ]
机构
[1] Univ Calif San Diego Hlth, Dept Radiol, San Diego, CA 92093 USA
[2] Univ Calif San Diego Hlth, Dept Radiat Med & Appl Sci, La Jolla, CA 92093 USA
[3] Univ Calif San Diego Hlth, Dept Neurosci, San Diego, CA USA
[4] Univ Calif San Diego, Halicioglu Data Sci Inst, San Diego, CA USA
[5] Univ Calif San Diego, Jacobs Sch Engn, Dept Bioengn, San Diego, CA 92093 USA
[6] Univ Chicago, Dept Radiol, Chicago, IL USA
[7] Univ Chicago, Sanford J Grossmann Ctr Excellence Prostate Imagin, Chicago, IL USA
基金
美国国家卫生研究院;
关键词
Diffusion-weighted imaging; Prostate cancer; Synthetic high b-values; Restricted Spectrum Imaging; FEASIBILITY; DIAGNOSIS; PERFUSION; IMAGES; TISSUE; DWI;
D O I
10.1186/s40644-024-00723-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background High b-value diffusion-weighted images (DWI) are used for detection of clinically significant prostate cancer (csPCa). This study qualitatively and quantitatively compares synthesized DWI (sDWI) to acquired (aDWI) for detection of csPCa. Methods One hundred fifty-one consecutive patients who underwent prostate MRI and biopsy were included in the study. Axial DWI with b = 0, 500, 1000, and 2000 s/mm(2) using a 3T clinical scanner using a 32-channel phased-array body coil were acquired. We retrospectively synthesized DWI for b = 2000 s/mm(2) via extrapolation based on mono-exponential decay, using b = 0 and b = 500 s/mm(2) (sDWI(500)) and b = 0, b = 500 s/mm(2), and b = 1000 s/mm(2) (sDWI(1000)). Differences in signal intensity between sDWI and aDWI were evaluated within different regions of interest (prostate alone, prostate plus 5 mm, 30 mm and 70 mm margin and full field of view). The maximum DWI value within each ROI was evaluated for prediction of csPCa. Classification accuracy was compared to Restriction Spectrum Imaging restriction score (RSIrs), a previously validated biomarker based on multi-exponential DWI. Discrimination of csPCa was evaluated via area under the receiver operating characteristic curve (AUC). Results Within the prostate, mean +/- standard deviation of percent mean differences between sDWI and aDWI signal were -46 +/- 35% for sDWI(1000) and -67 +/- 24% for sDWI(500). AUC for aDWI, sDWI(500,) sDWI(1000), and RSIrs within the prostate 0.62[95% confidence interval: 0.53, 0.71], 0.63[0.54, 0.72], 0.65[0.56, 0.73] and 0.78[0.71, 0.86], respectively. Conclusions DWI is qualitatively comparable to aDWI within the prostate. However, hyperintense artifacts are introduced with sDWI in the surrounding pelvic tissue that interfere with quantitative cancer detection and might mask metastases. In the prostate, RSIrs yields superior quantitative csPCa detection than sDWI or aDWI.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ultra-High b-Value Diffusion-Weighted Imaging-Based Abbreviated Protocols for Breast Cancer Detection
    Ohlmeyer, Sabine
    Laun, Frederik Bernd
    Bickelhaupt, Sebastian
    Palm, Theresa
    Janka, Rolf
    Weiland, Elisabeth
    Uder, Michael
    Wenkel, Evelyn
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 629 - 636
  • [22] ADC-Based Stratification of Molecular Glioma Subtypes Using High b-Value Diffusion-Weighted Imaging
    Nuessle, Nils C.
    Behling, Felix
    Tabatabai, Ghazaleh
    Vega, Salvador Castaneda
    Schittenhelm, Jens
    Ernemann, Ulrike
    Klose, Uwe
    Hempel, Johann-Martin
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (16)
  • [23] Assessment of Response to Radiotherapy for Prostate Cancer: Value of Diffusion-Weighted MRI at 3 T
    Song, Inyoung
    Kim, Chan Kyo
    Park, Byung Kwan
    Park, Won
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) : W477 - W482
  • [24] Increased signal intensity of prostate lesions on high b-value diffusion-weighted images as a predictive sign of malignancy
    Michael Quentin
    Lars Schimmöller
    Christian Arsov
    Robert Rabenalt
    Gerald Antoch
    Peter Albers
    Dirk Blondin
    European Radiology, 2014, 24 : 209 - 213
  • [25] Increased signal intensity of prostate lesions on high b-value diffusion-weighted images as a predictive sign of malignancy
    Quentin, Michael
    Schimmoeller, Lars
    Arsov, Christian
    Rabenalt, Robert
    Antoch, Gerald
    Albers, Peter
    Blondin, Dirk
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 209 - 213
  • [26] Microstructure Modeling of High b-Value Diffusion-Weighted Images in Glioblastoma
    Li, Yuan
    Kim, Michelle
    Lawrence, Theodore S.
    Parmar, Hemant
    Cao, Yue
    TOMOGRAPHY, 2020, 6 (01) : 34 - 43
  • [27] Diffusion-Weighted MRI at 3 T for the Evaluation of Prostate Cancer
    Kim, Chan Kyo
    Park, Byung Kwan
    Kim, Bohyun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) : 1461 - 1469
  • [28] High b-value diffusion-weighted imaging in progressive multifocal leukoencephalopathy in HIV patients
    Godi, Claudia
    De Vita, Enrico
    Tombetti, Enrico
    Davagnanam, Indran
    Haddow, Lewis
    Jager, Hans Rolf
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3593 - 3599
  • [29] Low b-value diffusion-weighted imaging: Emerging applications in the body
    Takahara, Taro
    Kwee, Thomas C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (06) : 1266 - 1273
  • [30] Diagnostic accuracy of ultra-high-b-value 3.0-T diffusion-weighted MR imaging for detection of prostate cancer
    Ohgiya, Yoshimitsu
    Suyama, Jumpei
    Seino, Noritaka
    Hashizume, Takashi
    Kawahara, Masaaki
    Sai, Syouei
    Saiki, Makoto
    Munechika, Jiro
    Hirose, Masanori
    Gokan, Takehiko
    CLINICAL IMAGING, 2012, 36 (05) : 526 - 531