Frequency response analysis in motors with shaft voltage mitigation methods

被引:0
作者
Im J.-H. [1 ]
Park J.-K. [2 ]
Hur J. [1 ]
机构
[1] Dept. of Electrical Engineering, Incheon National University
关键词
Bearing fault; Common-mode voltage; Motor fault; PWM inverter; Shaft voltage;
D O I
10.5370/KIEE.2020.69.3.427
中图分类号
学科分类号
摘要
In PWM based inverter driven motor, shaft voltages usually cause bearing fault. Many methods to mitigate the shaft voltages have been proposed. Since the high frequency components are hazardous to bearing, it is necessary to analyze the frequency responses for each shaft voltage mitigation method. In this paper, frequency responses of three shaft voltage mitigation methods are analyzed and compared. First, equivalent circuit models regarding geometric shape of motor are presented. Second, modified models of each equivalent circuit containing shaft voltage reduction methods are proposed. Finally, the comparison of the frequency responses for each shaft voltage mitigation method is presented. Copyright © The Korean Institute of Electrical Engineers.
引用
收藏
页码:427 / 434
页数:7
相关论文
共 11 条
[1]  
Zhang P., Du Y., Habetler T.G., Lu B., A survey of condition monitoring and protection methods for MediumVoltage induction motors, IEEE Transactions on Industry Applications, 47, 1, pp. 34-46, (2011)
[2]  
Singleton R.K., Strangas E.G., Aviyente S., The use of bearing currents and vibrations in lifetime estimation of bearings, IEEE Transactions on Industrial Informatics, 13, 3, pp. 1301-1309, (2017)
[3]  
Park J., Wellawatta T.R., Choi S., Hur J., Mitigation method of the shaft voltage according to parasitic capacitance of the PMSM, IEEE Transactions on Industry Applications, 53, 5, pp. 4441-4449, (2017)
[4]  
Park J., Wellawatta T.R., Ullah Z., Hur J., New equivalent circuit of the IPM-type BLDC motor for calculation of shaft voltage by considering electric and magnetic fields, IEEE Transactions on Industry Applications, 52, 5, pp. 3763-3771, (2016)
[5]  
Erdman J.M., Kerkman R.J., Schlegel D.W., Skibinski G.L., Effect of PWM inverters on AC motor bearing currents and shaft voltages, IEEE Transactions on Industry Applications, 32, 2, pp. 250-259, (1996)
[6]  
Asefi M., Nazarzadeh J., Survey on high-frequency models of PWM electric drives for shaft voltage and bearing current analysis, IET Electrical Systems in Transportation, 7, 3, pp. 179-189, (2017)
[7]  
Romanenko A., Muetze A., Ahola J., Effects of electrostatic discharges on bearing grease dielectric strength and composition, IEEE Transactions on Industry Applications, 52, 6, pp. 4835-4842, (2016)
[8]  
Niskanen V., Muetze A., Ahola J., Study on bearing impedance properties at several hundred kilohertz for different electric machine operating parameters, IEEE Trans. Ind. Appl., 50, 5, (2014)
[9]  
Muetze A., Tamminen J., Ahola J., Influence of motor operating parameters on discharge bearing current activity, IEEE Transactions on Industry Applications, 47, 4, pp. 1767-1777, (2011)
[10]  
Park J., Thusitha W., Choi S., Hur J., Shaft-to-frame voltage suppressing approach by applying eletromagnetic shield in IPMSM, Proc. Of 2017 IEEE International Electric Machines and Drives Conference (IEMDC), pp. 1-7, (2017)