Reshaping Model Predictive Control Penalties for an Automated Insulin Delivery System in Type 1 Diabetes

被引:0
作者
Moscoso-Vasquez, Marcela [1 ]
Garcia-Tirado, Jose [1 ]
Colmegna, Patricio [1 ]
Breton, Marc [1 ]
机构
[1] Univ Virginia, Ctr Diabet Technol, Charlottesville, VA 22903 USA
来源
IFAC PAPERSONLINE | 2023年 / 56卷 / 02期
关键词
Optimal control; Model predictive control; Artificial Pancreas system; Type; 1; diabetes; time-varying costs;
D O I
10.1016/j.ifacol.2023.10.274
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Model Predictive Control ( MPC) is one of the most popular control algorithms for Automated Insulin Delivery (AID) in Type 1 Diabetes ( T1D). So far, several MPC formulations of varying complexity have been proposed, but there is still no general consensus on how to define their cost weights. In this work, we evaluate the performance impact of reshaping the error weight (Q(z)) of RocketAP, a previously developed MPC-based AID system that has been successfully tested in in-silico and in-vivo trials. We analyzed two strategies: (i) a constant Q(z) and (ii) a Q(z) that is a function of the estimated Insulin on Board (IOB), Q(z)(IOB). In both cases, function parameters are determined via grid search with a cost function computed from glycemic outcome metrics. Performance is assessed on the 100-adult cohort of the FDA-accepted UVA/Padova metabolic simulator by clamping the time spent below 70 mg/dL (TBR), and comparing the achievable time spent between 70-180 mg/dL (TIR) and time spent above 250 mg/dL (TAR) in two different 48-hour scenarios. Results indicate that detuning the controller as a function of IOB, Q(z)(IOB), leads to significantly better (p<inverted exclamation>0.001, t-test) glycemic control ( TIR = 78 +/- 10.6%) compared to using a constant error weight in the MPC formulation ( TIR = 70 +/- 9.3%). Copyright (c) 2023 The Authors.
引用
收藏
页码:9660 / 9665
页数:6
相关论文
共 16 条
[1]   TOWARD PHYSIOLOGICAL UNDERSTANDING OF GLUCOSE-TOLERANCE - MINIMAL-MODEL APPROACH [J].
BERGMAN, RN .
DIABETES, 1989, 38 (12) :1512-1527
[2]  
Boiroux Dimitri, 2017, J Diabetes Sci Technol, V11, P29, DOI 10.1177/1932296816666295
[3]   Impact of Accelerating Insulin on an Artificial Pancreas System Without Meal Announcement: An In Silico Examination [J].
Colmegna, Patricio ;
Cengiz, Eda ;
Garcia-Tirado, Jose ;
Kraemer, Kristen ;
Breton, Marc D. .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (04) :833-841
[4]   Advanced hybrid artificial pancreas system improves on unannounced meal response-In silico comparison to currently available system [J].
Garcia-Tirado, Jose ;
Lv, Dayu ;
Corbett, John P. ;
Colmegna, Patricio ;
Breton, Marc D. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 211
[5]  
Garcia-Tirado Jose, 2019, J Diabetes Sci Technol, V13, P1054, DOI 10.1177/1932296819879084
[6]   Velocity-weighting & velocity-penalty MPC of an artificial pancreas: Improved safety & performance [J].
Gondhalekar, Ravi ;
Dassau, Eyal ;
Doyle, Francis J., III .
AUTOMATICA, 2018, 91 :105-117
[7]   Performance Assessment and Modification of an Adaptive Model Predictive Control for Automated Insulin Delivery by a Multivariable Artificial Pancreas [J].
Hajizadeh, Iman ;
Samadi, Sediqeh ;
Sevil, Mert ;
Rashid, Mudassir ;
Cinar, Ali .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2019, 58 (26) :11506-11520
[8]   Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes [J].
Hovorka, R ;
Canonico, V ;
Chassin, LJ ;
Haueter, U ;
Massi-Benedetti, M ;
Federici, MO ;
Pieber, TR ;
Schaller, HC ;
Schaupp, L ;
Vering, T ;
Wilinska, ME .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) :905-920
[9]  
Kovatchev Boris P, 2009, J Diabetes Sci Technol, V3, P44
[10]   Symmetrization of the blood glucose measurement scale and its applications [J].
Kovatchev, BP ;
Cox, DJ ;
GonderFrederick, LA ;
Clarke, W .
DIABETES CARE, 1997, 20 (11) :1655-1658