Chemical cleaning of aluminium alloy heat exchanger tube in low temperature multi-effect seawater desalination system

被引:0
|
作者
Jin, Ya-Peng [1 ]
Wu, Yun-Fang [1 ]
Cui, Zhen-Dong [1 ]
Gao, Li-Li [1 ]
Yin, Jian-Hua [1 ]
Wang, Wei-Zhen [1 ]
机构
[1] The Institute of Seawater Desalination and Multipurpose Utilization, MNR(Tianjin), Tianjin,300192, China
来源
Surface Technology | 2019年 / 48卷 / 02期
关键词
Aluminum alloys - Aluminum corrosion - Calcite - Calcium carbonate - Chemical analysis - Chemical cleaning - Copper corrosion - Corrosion protection - Corrosion rate - Desalination - Efficiency - Fluorescence spectroscopy - Fouling - Heat exchangers - Seawater corrosion - Sulfur compounds - Temperature - Tubes (components);
D O I
10.16490/j.cnki.issn.1001-3660.2019.02.029
中图分类号
学科分类号
摘要
The work aims to investigate the chemical cleaning technology of aluminum alloy heat exchanger tube in low temperature multi-effect desalination system and put the technology into field use. The chemical composition of scale on the aluminum alloy heat exchanger tube was analyzed by X-ray fluorescence spectroscopy (XRF). The corrosion rate of 5052 aluminum alloy in different cleaning agents was tested and the corrosion inhibition efficiency at different concentrations of corrosion inhibitors was evaluated in rotary coupon corrosion simulation test. During the field application, pH, Ca2+, Mg2+ concentra-tion of the system and corrosion rate of aluminum alloy were monitored to control the cleaning process and evaluate the cleaning effect. Main components of heat exchange tube scale were CaCO3 and CaSO4. In the selected cleaning agents, aluminum alloy corrosion rate was the highest in hydrochloric acid and the minimal in citric acid. Sulfamic acid was selected as the aluminum alloy heat exchanger tube cleaning agent because of corrosion and scale removal ability. At 40 °CS the corrosion rate of aluminum alloy in 4% sulfamic acid without and with 2 g/LHSD103 inhibitor was 1.434 mm/a and 0.084 mm/a respectively, which indicated that the corrosion inhibition efficiency was 94.14%. After that, increasing the corrosion inhibitor concentration did not obviously improve the corrosion inhibition efficiency. In the field, the average corrosion rate of aluminum alloy coupons was 0.146 mm/a and the corrosion inhibition efficiency was 90%. The acid cleaning process ended up after 21 h. After acid cleaning, the pH was stable around 2, the concentration of Ca2+ and Mg24 did not increase significantly and the scale on aluminum alloy heat exchanger tube was cleaned out. CaCO3 and CaSO4 scale on the aluminum alloy heat exchanger tubes can be effectively removed by sulfamic acid as cleaning agent, and the corrosion inhibitor has obvious protective effect on aluminum alloy so that good cleaning effect is obtained by field application. © 2019, Chongqing Wujiu Periodicals Press. All rights reserved.
引用
收藏
页码:200 / 206
相关论文
共 50 条
  • [31] Design and computer simulation on multi-effect evaporation seawater desalination system using hybrid renewable energy sources in Turkey
    Yilmaz, Ibrahim Halil
    Soylemez, Mehmet Sait
    DESALINATION, 2012, 291 : 23 - 40
  • [32] Development, 4E-analysis, and optimization of a seawater thermal energy-driven desalination system based on seawater source heat pump, multi-effect desalination, and pressure retarded osmosis with reduced effluent concentration
    Fadaei, Ahmad
    Noorollahi, Younes
    Pakzad, Pouria
    Yousefi, Hossein
    ENERGY CONVERSION AND MANAGEMENT, 2023, 298
  • [33] LOW-TEMPERATURE VAPOR COMPRESSION AND MULTI-EFFECT DISTILLATION OF SEAWATER - EFFECTS OF DESIGN ON OPERATION AND ECONOMICS
    MATZ, R
    ZIMERMAN, Z
    DESALINATION, 1985, 52 (02) : 201 - 216
  • [34] SOLAR PONDS AS HEAT SOURCE FOR LOW-TEMPERATURE MULTI-EFFECT DISTILLATION PLANTS
    TABOR, H
    DESALINATION, 1975, 17 (03) : 289 - 302
  • [35] SOLAR PONDS AS HEAT SOURCE FOR LOW-TEMPERATURE MULTI-EFFECT DISTILLATION PLANTS
    TABOR, H
    ANNALS OF ARID ZONE, 1976, 15 (03) : 155 - 171
  • [36] Study on multi-effect distillation of seawater with low-grade heat utilization of thermal power generating unit
    Xue, Yuan
    Du, Xiaoze
    Ge, Zhihua
    Yang, Lijun
    APPLIED THERMAL ENGINEERING, 2018, 141 : 589 - 599
  • [37] Thermodynamic and economic analysis of an integration system of multi-effect desalination (MED) with ice storage based on a heat pump
    Chen, Longxiang
    Liu, Xi
    Ye, Kai
    Xie, Meina
    Lan, Wenchao
    ENERGY, 2023, 283
  • [38] Low-temperature multi-effect evaporation desalination systems coupled with salinity-gradient solar ponds
    Leblanc, Jimmy
    Andrews, John
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 2151 - 2157
  • [39] Optimal feed flow sequence for multi-effect distillation system integrated with supercritical carbon dioxide Brayton cycle for seawater desalination
    Sharan, Prashant
    Neises, Ty
    Turchi, Craig
    JOURNAL OF CLEANER PRODUCTION, 2018, 196 : 889 - 901
  • [40] Thermodynamic analysis of an absorption-assisted multi-effect thermal desalination system with an extended operating temperature range