Evaluation of aquaporin based biomimetic forward osmosis membrane in terms of rejection performance for contaminants in greywater and its membrane fouling properties

被引:5
作者
Chen Y. [1 ]
Ren X. [1 ]
Huang M. [3 ]
Li Y. [1 ,2 ]
机构
[1] State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai
[2] Shanghai Institute of Pollution Control and Ecological Security, Shanghai
[3] Textile Pollution Controlling Engineering Centre of Ministry of Environmental Protection, College of Environmental Science and Engineering, Donghua University, Shanghai
关键词
Aquaporin membrane; Forward osmosis; Greywater; Membrane fouling; Microorganisms;
D O I
10.1016/j.chemosphere.2023.138983
中图分类号
学科分类号
摘要
Forward osmosis (FO) technology is regarded as an alternative to wastewater treatment due to its high permeate flux, excellent solute selectivity and low fouling tendency. In this study, two novel aquaporin based biomimetic membranes (ABMs) were used for comparison in short-term experiments to investigate the impact of membrane surface properties on greywater treatment. The impact of feed solution (FS) temperature on the filtration performance and membrane fouling behavior of ABM was further analyzed in the sequential batch experiments. Results indicated that the membranes with rough surface morphology and low zeta potential (absolute value) facilitated the adsorption of linear alklybezene sulfonates (LAS), thus improving the water flux and the rejection of Ca2+ and Mg2+. The increase in FS temperature enhanced the diffusion of organic matter and the water flux. In addition, sequential batch experiments showed that the membrane fouling layer was mainly in the form of organic and inorganic composite fouling, which was mitigated at FS temperature of 40 °C. Microbial community analysis revealed that the increase in FS temperature affected the diversity of microbial communities. More heterotrophic nitrifying bacteria were enriched in the fouling layer at FS 40 °C than at FS 20 °C. This study provides a novel strategy for employing ABM FO in greywater treatment and reuse. © 2023 Elsevier Ltd
引用
收藏
相关论文
共 69 条
  • [51] Wang C., Li Y., Wang Y., Treatment of greywater by forward osmosis technology: role of the operating temperature, Environ. Technol., 40, pp. 3434-3443, (2019)
  • [52] Wang C., Wang M., Li Y., Effects of sodium dodecyl sulfate on forward osmosis membrane fouling and its cleaning, Chemosphere, 257, (2020)
  • [53] Wang J., Liu X., Forward osmosis technology for water treatment: recent advances and future perspectives, J. Clean. Prod., 280, (2021)
  • [54] Wang Q., Zhou Z., Li J., Tang Q., Hu Y., Modeling and measurement of temperature and draw solution concentration induced water flux increment efficiencies in the forward osmosis membrane process, Desalination, 452, pp. 75-86, (2019)
  • [55] Wang X., Ye C., Zhang Z., Guo Y., Yang R., Chen S., Effects of temperature shock on N2O emissions from denitrifying activated sludge and associated active bacteria, Bioresour. Technol., 249, pp. 605-611, (2018)
  • [56] Wijeyekoon S., Carere C.R., West M., Nath S., Gapes D., Mixed culture polyhydroxyalkanoate (PHA) synthesis from nutrient rich wet oxidation liquors, Water Res., 140, pp. 1-11, (2018)
  • [57] Wu B., Membrane-based technology in greywater reclamation: a review, Sci. Total Environ., 656, pp. 184-200, (2019)
  • [58] Xiao T., Dou P., Wang J., Song J., Wang Y., Li X.-M., He T., Concentrating greywater using hollow fiber thin film composite forward osmosis membranes: fouling and process optimization, Chem. Eng. Sci., 190, pp. 140-148, (2018)
  • [59] Xu J., Tran T.N., Lin H., Dai N., Removal of disinfection byproducts in forward osmosis for wastewater recycling, J. Membr. Sci., 564, pp. 352-360, (2018)
  • [60] Xu X., Zhang H., Gao T., Wang Y., Teng J., Lu M., Customized thin and loose cake layer to mitigate membrane fouling in an electro-assisted anaerobic forward osmosis membrane bioreactor (AnOMEBR), Sci. Total Environ., 729, (2020)