Pulmonary Vein Isolation with a Novel Size-Adjustable Cryo-Balloon Catheter: A Tailored Ablation Protocol

被引:1
|
作者
Teumer, Yannick [1 ]
Hilgarth, Franziska [1 ]
Katov, Lyuboslav [1 ]
Melnic, Rima [1 ]
Rottbauer, Wolfgang [1 ]
Bothner, Carlo [1 ]
Weinmann, Karolina [1 ]
机构
[1] Ulm Univ, Heart Ctr, Dept Cardiol, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
atrial fibrillation; pulmonary vein isolation; cryo-balloon; size-adjustable cryo-balloon; PolarX Fit; ATRIAL-FIBRILLATION;
D O I
10.3390/jcm13082262
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments during ablation, lacks sufficient data on optimal utilization in patient care. This study aims to systematically investigate this feature with a tailored ablation protocol. Methods: Our single-center prospective study included patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI with the size-adjustable CB from July 2023 to February 2024. Ablation was performed using the balloon size that provided better occlusion. The ablation protocol involved an initial occlusion test with the small balloon size (28 mm). If optimal occlusion (occlusion level 4) could not be achieved, an attempt with the larger balloon (31 mm) was initiated. Ablation was conducted using the balloon configuration that provided better occlusion of the pulmonary vein ostium. Results: Our prospective study includes 50 patients (median age [interquartile range, IQR]: 72 [65; 79] years, 24 [48.0%] females, and 35 [70.0%] patients with paroxysmal AF). The median procedure duration (IQR) was 77 (65; 96) minutes, and the median fluoroscopy time (IQR) was 17.7 (12.5; 22.0) min. PVI was successfully accomplished in each treated pulmonary vein (PV), with 87.4% of PVs isolated during the first freeze. The large balloon configuration was used to isolate 16.8% of PVs. Conclusions: The utilization of the size-adjustable CB, combined with the presented tailored ablation workflow, appears to facilitate effective and efficient pulmonary vein isolation. The use of a larger balloon configuration appears beneficial in isolating a significant proportion of the PVs.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Pulmonary vein stenosis after pulmonary vein ablation catheter-guided pulmonary vein isolation
    De Greef, Yves
    Schwagten, Bruno
    De Keulenaer, Gilles
    Stockman, Dirk
    HEART RHYTHM, 2010, 7 (09) : 1306 - 1308
  • [22] The Permanency of Pulmonary Vein Isolation Using a Balloon Cryoablation Catheter
    Ahmed, Humera
    Neuzil, Petr
    Skoda, Jan
    D'Avila, Andre
    Donaldson, David M.
    Laragy, Margaret C.
    Reddy, Vivek Y.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (07) : 731 - 737
  • [23] The Anatomic Impact of Sequential, Additional, Ostial Radiofrequency Ablation Following Pulmonary Vein Cryo-Isolation
    Traulle, Sarah
    Miyazaki, Shinsuke
    Mouquet, Vincent
    Kubala, Maciej
    Hermida, Jean-Sylvain
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (12): : 1420 - 1427
  • [24] A Novel Microwave Catheter Can Perform Noncontact Circumferential Endocardial Ablation in a Model of Pulmonary Vein Isolation
    Qian, Pierre
    Barry, Michael Anthony
    Nguyen, Trang
    Ross, David
    Kovoor, Pramesh
    Mcewan, Alistair
    Thomas, Stuart
    Thiagalingam, Aravinda
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (07) : 799 - 804
  • [25] Evaluation of Pulmonary Vein Stenosis After Pulmonary Vein Isolation Using a Novel Circular Mapping and Ablation Catheter (PVAC)
    von Bary, Christian
    Weber, Stefan
    Dornia, Christian
    Eissnert, Christoph
    Fellner, Claudia
    Latzin, Philipp
    Fredersdorf, Sabine
    Stadler, Stefan
    Hamer, Okka W.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05): : 630 - 636
  • [26] A PRACTICAL MODEL OF BALLOON/TISSUE CONTACT IN PULMONARY VEIN ISOLATION WITH CRYOBALLOON ABLATION
    Smith, David J.
    Murthy, Sam
    Liao, Yu
    PROCEEDINGS OF THE 2024 DESIGN OF MEDICAL DEVICES CONFERENCE, DMD2024, 2024,
  • [27] Novel Radiofrequency Balloon Catheter-Impact of Ablation Parameters on Single-Shot Isolation
    My, Ilaria
    Bordignon, Stefano
    Butt, Mahi
    Rottner, Laura
    Marc, Lemoine
    Moser, Fabian
    Wenzel, Jan -Per
    Obergassel, Julius
    Schleberger, Ruben
    Moser, Julia
    Dinshaw, Leon
    Kirchhof, Paulus
    Reissmann, Bruno
    Ouyang, Feifan
    Chun, Kyoung-Ryul Julian
    Schmidt, Boris
    Rillig, Andreas
    Metzner, Andreas
    CIRCULATION JOURNAL, 2023, 87 (07) : 950 - 956
  • [28] Right ventricular rapid pacing in catheter ablation of atrial fibrillation: a novel application for cryoballoon pulmonary vein isolation
    K. R. Julian Chun
    Alexander Fürnkranz
    Boris Schmidt
    Andreas Metzner
    Roland Tilz
    Thomas Zerm
    Ilka Köster
    Buelent Koektuerk
    Melanie Konstantinidou
    Feifan Ouyang
    Karl Heinz Kuck
    Clinical Research in Cardiology, 2009, 98 : 493 - 500
  • [29] Right ventricular rapid pacing in catheter ablation of atrial fibrillation: a novel application for cryoballoon pulmonary vein isolation
    Chun, K. R. Julian
    Fuernkranz, Alexander
    Schmidt, Boris
    Metzner, Andreas
    Tilz, Roland
    Zerm, Thomas
    Koester, Ilka
    Koektuerk, Buelent
    Konstantinidou, Melanie
    Ouyang, Feifan
    Kuck, Karl Heinz
    CLINICAL RESEARCH IN CARDIOLOGY, 2009, 98 (08) : 493 - 500
  • [30] Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation
    Pott, Alexander
    Petscher, Kerstin
    Baumhardt, Michael
    Stephan, Tilman
    Rattka, Manuel
    Paliskyte, Rima
    Bothner, Carlo
    Kessler, Mirjam
    Rottbauer, Wolfgang
    Dahme, Tillman
    HEART AND VESSELS, 2019, 34 (03) : 496 - 502