Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments during ablation, lacks sufficient data on optimal utilization in patient care. This study aims to systematically investigate this feature with a tailored ablation protocol. Methods: Our single-center prospective study included patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI with the size-adjustable CB from July 2023 to February 2024. Ablation was performed using the balloon size that provided better occlusion. The ablation protocol involved an initial occlusion test with the small balloon size (28 mm). If optimal occlusion (occlusion level 4) could not be achieved, an attempt with the larger balloon (31 mm) was initiated. Ablation was conducted using the balloon configuration that provided better occlusion of the pulmonary vein ostium. Results: Our prospective study includes 50 patients (median age [interquartile range, IQR]: 72 [65; 79] years, 24 [48.0%] females, and 35 [70.0%] patients with paroxysmal AF). The median procedure duration (IQR) was 77 (65; 96) minutes, and the median fluoroscopy time (IQR) was 17.7 (12.5; 22.0) min. PVI was successfully accomplished in each treated pulmonary vein (PV), with 87.4% of PVs isolated during the first freeze. The large balloon configuration was used to isolate 16.8% of PVs. Conclusions: The utilization of the size-adjustable CB, combined with the presented tailored ablation workflow, appears to facilitate effective and efficient pulmonary vein isolation. The use of a larger balloon configuration appears beneficial in isolating a significant proportion of the PVs.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Pulmonary Vein Isolation with Pulsed Field Ablation and Size-Adjustable Cryo-Balloon: A Comparative Procedural Analysis of First-Time Use
    Katov, Lyuboslav
    Teumer, Yannick
    Bothner, Carlo
    Rottbauer, Wolfgang
    Weinmann-Emhardt, Karolina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (11)
  • [2] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Evonich, Rudolph F.
    Nori, David M.
    Haines, David E.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2012, 34 (01) : 29 - 36
  • [3] Efficacy of pulmonary vein isolation with a novel hot balloon ablation catheter
    Rudolph F. Evonich
    David M. Nori
    David E. Haines
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 29 - 36
  • [4] Comparison between a Novel Radiofrequency-Balloon and a Standard Cryo-Balloon in Pulmonary Vein Isolation: A Propensity-Score-Matched Analysis
    Teumer, Yannick
    Miesbichler, Clemens
    Katov, Lyuboslav
    Mayer, Benjamin
    Rottbauer, Wolfgang
    Bothner, Carlo
    Weinmann, Karolina
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [5] Comparison of Balloon Catheter Ablation Technologies for Pulmonary Vein Isolation: The Laser Versus Cryo Study
    Bordignon, Stefano
    Chun, K. R. Julian
    Gunawardene, Melanie
    Fuernkranz, Alexander
    Urban, Verena
    Schulte-Hahn, Britta
    Nowak, Bernd
    Schmidt, Boris
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (09) : 987 - 994
  • [6] A case of prolonged sinus arrest for 5 minutes after Cryo-balloon ablation to the left superior pulmonary vein
    Miki, Tomonori
    Shiraishi, Hirokazu
    Shirayama, Takeshi
    Matoba, Satoaki
    JOURNAL OF ARRHYTHMIA, 2020, 36 (01) : 186 - 188
  • [7] Distribution of antral lesions with the novel size-adjustable cryoballoon for pulmonary vein isolation and the differences based on left atrial remodeling
    Goto, Kentaro
    Miyazaki, Shinsuke
    Negishi, Miho
    Ikenouchi, Takashi
    Yamamoto, Tasuku
    Kawamura, Iwanari
    Nishimura, Takuro
    Takamiya, Tomomasa
    Tao, Susumu
    Takigawa, Masateru
    Sasano, Tetsuo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (11) : 2099 - 2108
  • [8] Eccentric scar formation around a pulmonary vein after cryo-balloon ablation in a patient with atrial fibrillation: A case report
    Kiuchi, Kunihiko
    Fukuzawa, Koji
    Matsumoto, Akinori
    JOURNAL OF ARRHYTHMIA, 2016, 32 (03) : 230 - 232
  • [9] Pulmonary Vein Isolation with a Novel Direct Visualization Ablation Catheter
    McElderry, Tom
    Oley, Leslie
    Malchano, Zaxh
    Wylie, Bryan
    Yamada, Takumi
    Kay, G. N.
    CIRCULATION, 2010, 122 (21)
  • [10] Towards a tailored cryo-pulmonary vein isolation. Lessons learned from second-generation cryoballoon ablation
    Ciconte, Giuseppe
    Coulombe, Nicolas
    Brugada, Pedro
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    TRENDS IN CARDIOVASCULAR MEDICINE, 2019, 29 (07) : 420 - 425