Selective Angiographic Evaluation in Patients with Simple-Type Pulmonary Arteriovenous Malformations Treated with Vascular Plug

被引:0
作者
Wada, Shinji [1 ]
Hamaguchi, Shingo [1 ]
Hashimoto, Kazuki [1 ]
Nawata, Shintaro [1 ]
Matsuoka, Shin [1 ]
Mimura, Hidefumi [1 ]
机构
[1] St Marianna Univ, Dept Diagnost & Intervent Radiol, Sch Med, 2-16-1 Sugao,Miyamae Ku, Kawasaki, Kanagawa 2168511, Japan
关键词
Recanalization; Pulmonary arteriovenous malformation; AMPLATZER vascular plug; Embolization; VENOUS SAC EMBOLIZATION; RECANALIZATION; EMBOLOTHERAPY; SAFETY;
D O I
10.1007/s00270-024-03783-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo evaluate the angiographic recanalization rate of patients who underwent embolization juxta-proximal to the sac with AMPLATZER Vascular Plug type IV (AVP IV) for a simple pulmonary arteriovenous malformation (PAVM).Material and MethodsTen patients (7 females and 3 males; median age, 47 years [range 28-83 years]) with 19 simple-type PAVMs who underwent embolization using an AVP IV between May 2015 and November 2021 were included in this retrospective study. The median feeding artery diameter on computed tomography was 4.0 mm (range 3-5.9 mm), and the median ratio of AVP IV size to feeding artery diameter on computed tomography was 1.5 (range 1.3-2.1). Technical success was defined by AVP IV placement at the junction between the pulmonary artery and the sac, or the pulmonary artery within 1 cm from the junction and beyond the last normal branch. The primary endpoint was the PAVM recanalization rate in selective or segmental pulmonary angiography performed 1 year post-embolization.ResultsThe technical success rate of embolization juxta-proximal to the sac for simple-type PAVMs was 100%. None of the 19 lesions showed recanalization in pulmonary angiography performed 1 year after embolization. One patient experienced hemoptysis and pneumonia.ConclusionEmbolization of simple-type PAVMs' feeding vessel using AVP IV is safe and effective, with a high technical success rate and no recanalization on pulmonary angiography performed at 1 year post-embolization.Level of Evidence: 4ConclusionEmbolization of simple-type PAVMs' feeding vessel using AVP IV is safe and effective, with a high technical success rate and no recanalization on pulmonary angiography performed at 1 year post-embolization.Level of Evidence: 4
引用
收藏
页码:1101 / 1108
页数:8
相关论文
共 20 条
[1]   Long-Term Single-Center Retrospective Follow-Up After Embolization of Pulmonary Arteriovenous Malformations Treated Over a 20-year Period: Frequency of Re-canalization with Various Embolization Materials and Clinical Outcome [J].
Andersen, Poul Erik ;
Duvnjak, Stevo ;
Gerke, Oke ;
Kjeldsen, Anette Drohse .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (08) :1102-1109
[2]   Pulmonary arteriovenous malformations: Embolotherapy with superselective coaxial catheter placement and filling of venous sac with Guglielmi detachable coils [J].
Dinkel, HP ;
Triller, J .
RADIOLOGY, 2002, 223 (03) :709-714
[3]   Efficacy of Venous Sac Embolization for Pulmonary Arteriovenous Malformations: Comparison with Feeding Artery Embolization [J].
Hayashi, Sadao ;
Baba, Yasutaka ;
Senokuchi, Terutoshi ;
Nakajo, Masayuki .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (12) :1566-1577
[4]   Embolization using hydrogel-coated coils for pulmonary arteriovenous malformations [J].
Iguchi, T. ;
Hiraki, T. ;
Matsui, Y. ;
Fujiwara, H. ;
Sakurai, J. ;
Baba, K. ;
Toyooka, S. ;
Gobara, H. ;
Kanazawa, S. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2020, 101 (03) :129-135
[5]   Venous sac embolization of pulmonary arteriovenous malformation: safety and effectiveness at mid-term follow-up [J].
Kajiwara, Kenji ;
Urashima, Masaki ;
Yamagami, Takuji ;
Kakizawa, Hideaki ;
Matsuura, Noriaki ;
Matsuura, Akiko ;
Ohnari, Tae ;
Ishikawa, Masaki ;
Awai, Kazuo .
ACTA RADIOLOGICA, 2014, 55 (09) :1093-1098
[6]   Feasibility of Time-Resolved MR Angiography for Detecting Recanalization of Pulmonary Arteriovenous Malformations Treated with Embolization with Platinum Coils [J].
Kawai, Tatsuya ;
Shimohira, Masashi ;
Kan, Hirohito ;
Hashizume, Takuya ;
Ohta, Kengo ;
Kurosaka, Kenichiro ;
Muto, Masahiro ;
Suzuki, Kazushi ;
Shibamoto, Yuta .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (09) :1339-1347
[7]   Proposal of a New Adverse Event Classification by the Society of Interventional Radiology Standards of Practice Committee [J].
Khalilzadeh, Omid ;
Baerlocher, Mark O. ;
Shyn, Paul B. ;
Connolly, Bairbre L. ;
Devane, A. Michael ;
Morris, Christopher S. ;
Cohen, Alan M. ;
Midia, Mehran ;
Thornton, Raymond H. ;
Gross, Kathleen ;
Caplin, Drew M. ;
Aeron, Gunjan ;
Misra, Sanjay ;
Patel, Nilesh H. ;
Walker, T. Gregory ;
Martinez-Salazar, Gloria ;
Silberzweig, James E. ;
Nikolic, Boris .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (10) :1432-1437
[8]   Postembolization Persistence of Pulmonary Arteriovenous Malformations: A Retrospective Comparison of Coils and Amplatzer and Micro Vascular Plugs Using Propensity Score Weighting [J].
Latif, Muhammad A. ;
Bailey, Christopher R. ;
Motaghi, Mina ;
Abou Areda, Moustafa ;
Galiatsatos, Panagis ;
Mitchell, Sally E. ;
Weiss, Clifford R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2023, 220 (01) :95-103
[9]   Embolization of Pulmonary Arteriovenous Malformations with Amplatzer Vascular Plugs: Safety and Midterm Effectiveness [J].
Letourneau-Guillon, Laurent ;
Faughnan, Marie E. ;
Soulez, Gilles ;
Giroux, Marie-France ;
Oliva, Vincent L. ;
Boucher, Louis-Martin ;
Dubois, Josee ;
Prabhudesai, Vikram ;
Therasse, Eric .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 21 (05) :649-656
[10]   Pulmonary Arteriovenous Malformations: Safety and Efficacy of Microvascular Plugs [J].
Mahdjoub, Elyas ;
Tavolaro, Sebastian ;
Parrot, Antoine ;
Cornelis, Francois ;
Khalil, Antoine ;
Carette, Marie-France .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (05) :1135-1143